Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Int Orthop ; 37(4): 667-72, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23359099

ABSTRACT

PURPOSE: A biomechanical study was performed to test the hypothesis that a new anatomically preformed, thinner, soft-tissue protecting plate system for distal humeral fractures (Tifix®-hybridplate [HP]) would show comparable results in the quasi-static and dynamic testings compared to two conventional implants: The 3.5-mm reconstruction plate (RP) providing primary stability with normal bone mineral density (BMD), and a multidirectional locking plate (Tifix(®)-plate [P]) which can be used with poor bone quality. METHODS: The Tifix(®)-HP was developed by the working group. The biomechanical testing was performed on a C2-fracture-model in 24 synthetic humeri. Three groups, each with eight bone-implant-constructs, were analysed in quasi-static and dynamic tests. RESULTS: The quasi-static measurements showed that under extension loading both locking plates (Tifix(®)-P, Tifix(®)-HP) were significantly stiffer than the reconstruction plate, and that the Tifix(®)-HP had a significantly lower stiffness than the two other implants under flexion loading. In the dynamic tests the Tifix(®)-P allowed significantly less fracture motion compared to the Tifix(®)-HP and the reconstruction plate. In an osteopaenic bone model locking plates failed only under much higher dynamic force than the reconstruction plate. The reconstruction plate and the Tifix(®)-P always failed through screw loosening, whereas the newly developed Tifix(®)-HP showed screw loosening in only one third of cases. CONCLUSION: The hypothesis that the newly designed plate system showed comparable results in the quasi-static and dynamic tests compared to the conventional implants with a significantly lower implant volume and thickness was confirmed.


Subject(s)
Bone Plates , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Humeral Fractures/surgery , Internal Fixators , Biomechanical Phenomena , Bone Screws , Humans , Humerus/injuries , Humerus/surgery , Materials Testing , Stress, Mechanical
2.
BMC Musculoskelet Disord ; 13: 141, 2012 Aug 08.
Article in English | MEDLINE | ID: mdl-22873207

ABSTRACT

BACKGROUND: A minimal invasive approach for elective hip surgery has been implemented in our institution in the past. It is widely hypothesized that implanting artificial hips in a minimal invasive fashion decreases surgical trauma and is helpful in the rehabilitation process in elective hip surgery. Thereby geriatric patients requiring emergency hip surgery also could theoretically benefit from a procedure that involves less tissue trauma. METHODS: Sixty patients who sustained a fractured neck of femur were randomly assigned into two groups. In the minimal invasive arm, the so called "direct anterior approach" (DAA) was chosen, in the conventional arm the Watson-Jones-Approach was used for implantation of a bipolar hemi-arthroplasty.Primary outcome parameter was the mobility as measured by the four-item-Barthel index. Secondary outcome parameters included pain, haemoglobin-levels, complications, duration of surgery, administration of blood transfusion and external length of incision. Radiographs were evaluated. RESULTS: A statistically significant difference (p = 0,009) regarding the mobility as measured with the four-item Barthel index was found at the 5th postoperative day, favouring the DAA. Evaluation of the intensity of pain with a visual analogue scale (VAS) showed a statistically significant difference (p = 0,035) at day 16. No difference was evident in the comparison of radiographic results. CONCLUSIONS: Comparing two different approaches to the hip joint for the implantation of a bipolar hemi-arthroplasty after fractured neck of femur, it can be stated that mobilization status is improved for the DAA compared to the WJA when measured by the four-item Barthel index, there is less pain as measured using the VAS. There is no radiographic evidence that a minimal invasive technique leads to inferior implant position. LEVEL OF EVIDENCE: Level II therapeutic study.


Subject(s)
Femoral Neck Fractures/surgery , Hemiarthroplasty/methods , Hip Joint/surgery , Activities of Daily Living , Aged , Aged, 80 and over , Biomechanical Phenomena , Disability Evaluation , Female , Femoral Neck Fractures/diagnostic imaging , Femoral Neck Fractures/physiopathology , Fracture Healing , Germany , Hemiarthroplasty/adverse effects , Hip Joint/diagnostic imaging , Hip Joint/physiopathology , Humans , Male , Minimally Invasive Surgical Procedures , Mobility Limitation , Pain Measurement , Pain, Postoperative/diagnosis , Pain, Postoperative/etiology , Prospective Studies , Radiography , Recovery of Function , Time Factors , Treatment Outcome
SELECTION OF CITATIONS