Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Heliyon ; 10(3): e25829, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38356502

ABSTRACT

Objectives: The biomechanical response of teeth with periapical lesions that have been restored using various substructure materials, as well as the stress mapping in the alveolar bone, has not been thoroughly described. In this context, the objective of this study is to investigate the structural stress distributions on root canal-treated maxillary right central incisors with lesions restored using different crown materials under linear static loading conditions through finite element analysis (FEA). Methods: In the study, five FEA models were utilised to represent healthy teeth and teeth restored with different substructure materials: (A) a healthy tooth, (B) a lesioned, root canal-treated, composite-filled tooth, (C) a lesioned, fiber-posted, zirconia-based crown, (D) a tooth with lesions, a fiber post, and Ni-Cr infrastructure crown, (E) a tooth with a lesion, a fiber post, and an IPS E-max infrastructure crown. A force of 100 N was applied at an angle of 45° to the long axis of the tooth from 2 mm cervical to the incisal line on the palatal surface. Deformation behaviour and maximum equivalent stress distributions on the tooth sub-components, including the bony structure for each model, were simulated. Results: Differences were observed in the stress distributions of the models. The maximum stress values of the models representing the restorations with different infrastructures varied, and the highest value was obtained in the model of the E-max crown (Model E: 136.050 MPa). The minimum stress magnitudes were obtained from Model B the composite-filled tooth (80.39 MPa); however, it was observed that the equivalent stresses in all the models showed a similar distribution for all components with varying magnitudes. In periapical lesion areas, low stresses were observed. In all models, the cervicobuccal collar region of the teeth had dense equivalent stresses. Conclusion: Different restorative treatment methods applied to root canal-treated teeth with periapical lesions can impact the stress in the alveolar bone and the biomechanical response of the tooth. Relatively high stress values in the cortical bone at the cervical line of the tooth have been observed to decrease towards the apical region. This observation may suggest a potential healing effect by reducing pressure in the periapical lesion area. Clinical significance: Composite resin restorations can be considered the first-choice treatment option for the restoration of root canal-treated teeth with lesions. In crown restorations, it would be advantageous to prefer zirconia or metal-supported prostheses in terms of biomechanics.

2.
Heliyon ; 9(6): e17462, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37484349

ABSTRACT

Background/purpose: Additive manufacturing (AM), also known as 3D printing, has the potential to transform the industry. While there have been advancements in using AM for dental restorations, there is still a need for further research to develop functional biomedical and dental materials. It's crucial to understand the current status of AM technology and research trends to advance dental research in this field. The aim of this study is to reveal the current status of international scientific publications in the field of dental research related to AM technologies. Materials and methods: In this study, a systematic scoping review was conducted using appropriate keywords within the scope of international scientific publishing databases (PubMed and Web of Science). The review included related clinical and laboratory research, including both human and animal studies, case reports, review articles, and questionnaire studies. A total of 187 research studies were evaluated for quantitative synthesis in this review. Results: The findings highlighted a rising trend in research numbers over the years (From 2012 to 2022). The most publications were produced in 2020 and 2021, with annual percentage increases of 25.7% and 26.2%, respectively. The majority of AM-related publications in dentistry research originate from Korea. The pioneer dental sub-fields with the ost publications in its category are prosthodontics and implantology, respectively. Conclusion: The final review result clearly stated an expectation for the future that the research in dentistry would concentrate on AM technologies in order to increase the new product and process development in dental materials, tools, implants and new generation modelling strategy related to AM. The results of this work can be used as indicators of trends related to AM research in dentistry and/or as prospects for future publication expectations in this field.

3.
Materials (Basel) ; 16(4)2023 Feb 19.
Article in English | MEDLINE | ID: mdl-36837352

ABSTRACT

The investigation of mould inserts in the injection moulding process using metal epoxy composite (MEC) with pure metal filler particles is gaining popularity among researchers. Therefore, to attain zero emissions, the idea of recycling metal waste from industries and workshops must be investigated (waste free) because metal recycling conserves natural resources while requiring less energy to manufacture new products than virgin raw materials would. The utilisation of metal scrap for rapid tooling (RT) in the injection moulding industry is a fascinating and potentially viable approach. On the other hand, epoxy that can endure high temperatures (>220 °C) is challenging to find and expensive. Meanwhile, industrial scrap from coal-fired power plants can be a precursor to creating geopolymer materials with desired physical and mechanical qualities for RT applications. One intriguing attribute of geopolymer is its ability to endure temperatures up to 1000 °C. Nonetheless, geopolymer has a higher compressive strength of 60-80 MPa (8700-11,600 psi) than epoxy (68.95 MPa) (10,000 psi). Aside from its low cost, geopolymer offers superior resilience to harsh environments and high compressive and flexural strength. This research aims to investigate the possibility of generating a new sustainable material by integrating several types of metals in green geopolymer metal composite (GGMC) mould inserts for RT in the injection moulding process. It is necessary to examine and investigate the optimal formulation of GGMC as mould inserts for RT in the injection moulding process. With less expensive and more ecologically friendly components, the GGMC is expected to be a superior choice as a mould insert for RT. This research substantially impacts environmental preservation, cost reduction, and maintaining and sustaining the metal waste management system. As a result of the lower cost of recycled metals, sectors such as mould-making and machining will profit the most.

4.
Knee ; 37: 132-142, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35779431

ABSTRACT

BACKGROUND: Antero-medialisation osteotomy combined with a distalisation procedure may require a more stable fixation as the osteotomy fragment loses both proximal and distal support. This finite element analysis aimed to compare the mechanical behaviour of different fixation techniques in tibial tubercle antero-medialisation osteotomy combined with distalisation procedure. METHODS: Tibial tubercle osteotomy combined with distalisation was modelled based on computerised tomography data, which were acquired from a patient with patellar instability requiring this procedure. Six different fixation configurations with two 3.5-mm cortical screws (1), two 4.5-mm cortical screws (2), three 3.5-mm cortical screws (3), three 4.5-mm cortical screws (4), three 3.5-mm screws with 1/3 tubular plate (5), and four 3.5-mm screws with 1/3 tubular plate (6) were created. A total of 1654 N of force was applied to the patellar tendon footprint on the tibial tubercle. Sliding, gap formation, and total deformation between the osteotomy components were analyzed. RESULTS: Maximum sliding (0.660 mm), gap formation (0.661 mm), and displacement (1.267 mm) were seen with two 3.5-mm screw fixation, followed by two 4.5-mm screws, three 3.5-mm screws, and three 4.5-mm screws, respectively, in the screw-only group. Overall, the minimum displacement was observed with the four 3.5-mm screws with 1/3 tubular plate fixation model. CONCLUSIONS: Plate fixation might be recommended for tibial tubercle antero-medialisation osteotomy combined with distalisation procedure because it might allow early active range of motion exercises and weight-bearing.


Subject(s)
Joint Instability , Patellofemoral Joint , Biomechanical Phenomena , Bone Plates , Bone Screws , Finite Element Analysis , Humans , Osteotomy/methods , Tibia/diagnostic imaging , Tibia/surgery
5.
Materials (Basel) ; 15(10)2022 May 23.
Article in English | MEDLINE | ID: mdl-35629751

ABSTRACT

Rapid tooling (RT) and additive manufacturing (AM) are currently being used in several parts of industry, particularly in the development of new products. The demand for timely deliveries of low-cost products in a variety of geometrical patterns is continuing to increase year by year. Increased demand for low-cost materials and tooling, including RT, is driving the demand for plastic and rubber products, along with engineering and product manufacturers. The development of AM and RT technologies has led to significant improvements in the technologies, especially in testing performance for newly developed products prior to the fabrication of hard tooling and low-volume production. On the other hand, the rapid heating cycle molding (RHCM) injection method can be implemented to overcome product surface defects generated by conventional injection molding (CIM), since the surface gloss of the parts is significantly improved, and surface marks such as flow marks and weld marks are eliminated. The most important RHCM technique is rapid heating and cooling of the cavity surface, which somewhat improves part quality while also maximizing production efficiencies. RT is not just about making molds quickly; it also improves molding productivity. Therefore, as RT can also be used to produce products with low-volume production, there is a good potential to explore RHCM in RT. This paper reviews the implementation of RHCM in the molding industry, which has been well established and undergone improvement on the basis of different heating technologies. Lastly, this review also introduces future research opportunities regarding the potential of RT in the RHCM technique.

6.
Proc Inst Mech Eng H ; 236(6): 825-840, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35445623

ABSTRACT

Malleolar screw fixation is the most widely used treatment method for medial malleolar (MM) fractures. Here, although buttress plate fixation is advocated for vertical MM fractures, the angular discrimination between oblique and vertical MM fractures is still not fully understood. The purpose of this study is to test the adequacy of screw fixation in MM fractures with different angles and determination of a 'critical fracture angle' to guide surgeons in the decision-making for screw fixation for MM fractures by utilizing an advanced engineering simulation approach. In addition to loading of the healthy tibia structure, various cases of the MM fracture double screw fixation (14 simulation scenarios in total with fracture angles between 30° and 90°, in 5° increments) were considered in this research and their static loading conditions just after fixation operation were simulated through nonlinear (geometric and contact nonlinearity) finite element analysis (FEA). Patient-specific computed tomography scan data, parametric three-dimensional solid modelling and finite element method (FEM) based engineering codes were employed in order to simulate the fixation scenarios. Visual and numerical outputs for the deformation and stress distributions, separation and sliding behaviours of the MM fracture fragments of various screw fixations were clearly exhibited through FEA results. Minimum and maximum separation distances (gap) of 3.75 and 150.34 µm between fracture fragments at fracture angles of 30° and 90° were calculated respectively against minimum and maximum sliding distances of 25.87 and 41.37 µm between fracture fragments at fracture angles of 90° and 35°, respectively. The FEA results revealed that while the separation distance was increasing, the sliding distance was decreasing and there were no distinct differences in sliding distances in the scenarios from fracture angles of 30°-90°. The limitations and errors in a FEA study are inevitable, however, it was interpreted that the FEA scenarios were setup in this study by utilizing acceptable assumptions providing logical outputs under pre-defined boundary conditions. Finally, the fracture healing threshold for separation and/or sliding distance between fracture fragments was assigned as 100 µm by referring to previous literature and it was concluded that the screws fixed perpendicular to the fracture in a MM fracture with more than 70° angle with the tibial plafond results in a significant articular separation (>100 µm) during single-leg stand. Below this critical angle of 70°, two screws provide sufficient fixation.


Subject(s)
Ankle Fractures , Fracture Fixation, Internal , Ankle Fractures/diagnostic imaging , Ankle Fractures/surgery , Biomechanical Phenomena , Bone Plates , Bone Screws , Finite Element Analysis , Fracture Fixation, Internal/methods , Humans
7.
J Foot Ankle Surg ; 61(2): 253-258, 2022.
Article in English | MEDLINE | ID: mdl-34456133

ABSTRACT

This study aimed to evaluate different fixation techniques and implants in oblique and biplanar chevron medial malleolar osteotomies using finite element analysis. Both oblique and biplanar chevron osteotomy models were created, and each osteotomy was fixed with 2 different screws (3.5 mm cortical screw and 4.0 mm malleolar screw) in 2 different configurations; (1) 2 perpendicular screws, and (2) an additional third transverse screw. Nine simulation scenarios were set up, including 8 osteotomy fixations and the intact ankle. A bodyweight of 810.44 N vertical loading was applied to simulate a single leg stand on a fixed ankle. Sliding, separation, frictional stress, contact pressures between the fragments were analyzed. Maximum sliding (58.347µm) was seen in oblique osteotomy fixed with 2 malleolar screws, and the minimum sliding (17.272 µm) was seen in chevron osteotomy fixed with 3 cortical screws. The maximum separation was seen in chevron osteotomy fixed with 2 malleolar screws, and the minimum separation was seen in oblique osteotomy fixed with 3 cortical screws. Maximum contact pressure and the frictional stress at the osteotomy plane were obtained in chevron osteotomy fixed with 3 cortical screws. The closest value to normal tibiotalar contact pressures was obtained in chevron osteotomy fixed with 3 cortical screws. This study revealed that cortical screws provided better stability compared to malleolar screws in each tested osteotomy and fixation configuration. The insertion of the third transverse screw decreased both sliding and separation. Biplanar chevron osteotomy fixed with 3 cortical screws was the most stable model.


Subject(s)
Bone Screws , Osteotomy , Biomechanical Phenomena , Finite Element Analysis , Humans , Osteotomy/methods , Tibia/surgery
8.
Jt Dis Relat Surg ; 32(2): 355-362, 2021.
Article in English | MEDLINE | ID: mdl-34145811

ABSTRACT

OBJECTIVES: The aim of this study was to investigate the effect of cartilage thickness mismatch on tibiotalar articular contact pressure in osteochondral grafting from femoral condyles to medial talar dome using a finite element analysis (FEA). MATERIALS AND METHODS: Flush-implanted osteochondral grafting was performed on the talar centromedial aspect of the dome using osteochondral plugs with two different cartilage thicknesses. One of the plugs had an equal cartilage thickness with the recipient talar cartilage and the second plug had a thicker cartilage representing a plug harvested from the knee. The ankle joint was loaded during a single-leg stance phase of gait. Tibiotalar contact pressure, frictional stress, equivalent stress (von Mises values), and deformation were analyzed. RESULTS: In both osteochondral grafting simulations, tibiotalar contact pressure, frictional stress, equivalent stress (von Mises values) on both tibial and talar cartilage surfaces were restored to near-normal values. CONCLUSION: Cartilage thickness mismatch does not significantly change the tibiotalar contact biomechanics, when the graft is inserted flush with the talar cartilage surface.


Subject(s)
Ankle Joint/physiopathology , Ankle Joint/surgery , Cartilage, Articular/transplantation , Biomechanical Phenomena , Computer Simulation , Elastic Modulus , Femur , Finite Element Analysis , Friction , Humans , Knee Joint , Male , Pressure , Stress, Mechanical , Talus , Tibia
9.
Int J Bioprint ; 6(4): 286, 2020.
Article in English | MEDLINE | ID: mdl-33088997

ABSTRACT

During the coronavirus disease-19 pandemic, the demand for specific medical equipment such as personal protective equipment has rapidly exceeded the available supply around the world. Specifically, simple medical equipment such as medical gloves, aprons, goggles, surgery masks, and medical face shields have become highly in demand in the health-care sector in the face of this rapidly developing pandemic. This difficult period strengthens the social solidarity to an extent parallel to the escalation of this pandemic. Education and government institutions, commercial and noncommercial organizations and individual homemakers have produced specific medical equipment by means of additive manufacturing (AM) technology, which is the fastest way to create a product, providing their support for urgent demands within the health-care services. Medical face shields have become a popular item to produce, and many design variations and prototypes have been forthcoming. Although AM technology can be used to produce several types of noncommercial equipment, this rapid manufacturing approach is limited by its longer production time as compared to conventional serial/mass production and the high demand. However, most of the individual designer/maker-based face shields are designed with little appreciation of clinical needs and nonergonomic. They also lack of professional product design and are not designed according to AM (Design for AM [DfAM]) principles. Consequently, the production time of up to 4 - 5 h for some products of these designs is needed. Therefore, a lighter, more ergonomic, single frame medical face shield without extra components to assemble would be useful, especially for individual designers/makers and noncommercial producers to increase productivity in a shorter timeframe. In this study, a medical face shield that is competitively lighter, relatively more ergonomic, easy to use, and can be assembled without extra components (such as elastic bands, softening materials, and clips) was designed. The face shield was produced by AM with a relatively shorter production time. Subsequently, finite element analysis-based structural design verification was performed, and a three-dimensional (3D) prototype was produced by an original equipment manufacturer 3D printer (Fused Deposition Modeling). This study demonstrated that an original face shield design with <10 g material usage per single frame was produced in under 45 min of fabrication time. This research also provides a useful product DfAM of simple medical equipment such as face shields through advanced engineering design, simulation, and AM applications as an essential approach to battling coronavirus-like viral pandemics.

10.
Materials (Basel) ; 12(23)2019 Nov 26.
Article in English | MEDLINE | ID: mdl-31779238

ABSTRACT

Rapid Tooling processes are developing and proving to be a reliable method to compete with subtractive techniques for tool making. This paper investigates large volume production of components produced from Selective Laser Melting (SLM) fabricated injection moulding tool inserts. To date, other researchers have focused primarily on investigating the use of additive manufacturing technology for injection moulding for low-volume component production rather than high volume production. In this study, SLM technology has been used to fabricate four Stainless Steel 316L tool inserts of a similar geometry for an after-market automotive spare part. The SLM tool inserts have been evaluated to analyse the maximum number of successful injections and quality of performance. Microstructure inspection and chemical composition analysis have been investigated. Performance tests were conducted for the four tool inserts before and after injection moulding in the context of hardness testing and dimensional accuracy. For the first reported time, 150,000 injected products were successfully produced from the four SLM tool inserts. Tool inserts performance was monitored under actual operating conditions considering high-level demands. In the scope of this research, SLM proved to be a dependable manufacturing technique for most part geometries and an effective alternative to subtractive manufacturing for high-volume injection moulding tools for the aftermarket automotive sector.

11.
J Vis Commun Med ; 39(3-4): 99-104, 2016.
Article in English | MEDLINE | ID: mdl-27797295

ABSTRACT

This study investigates the use of 3D printing for patients that require localised radiotherapy treatment to the face. The current process involves producing a lead mask in order to protect the healthy tissue from the effects of the radiotherapy. The mask is produced by applying a thermoplastic sheet to the patient's face and allowing to set hard. This can then be used as a mould to create a plaster impression of the patient's face. A sheet of lead is then hammered on to the plaster to create a bespoke fitted face mask. This process can be distressing for patients and can be problematic when the patient is required to remain motionless for a prolonged time while the thermoplastic sets. In this study, a 1:1 scale 3D print of a patient's face was generated using a laser scanner. The lead was hammered directly on to the surface of the 3D print in order to create a bespoke fitted treatment mask. This eliminated the thermoplastic moulding stage and significantly reduced the time needed for the patient to be in clinic. The higher definition impression of the the face resulted in a more accurate, better fitting treatment mask.


Subject(s)
Masks , Printing, Three-Dimensional , Radiation Protection , Face , Humans , Radiotherapy
12.
Dent Update ; 30(6): 321-5, 2003.
Article in English | MEDLINE | ID: mdl-12955954

ABSTRACT

Since its inception, the Community Dental Service has evolved from a child-centred organization to its much wider remit of current times. This article reviews the present role of the CDS, examines the type of people who make up the workforce and considers what a career in community dental practice can offer to new or recent graduates. Specialization in community or special needs dentistry is not an option at the moment. However, a number of appropriate training opportunities leading to further qualifications are highlighted and are becoming more readily accessible.


Subject(s)
Career Choice , Community Dentistry , Community Dentistry/education , Education, Dental, Graduate , Female , Humans , Male , Preceptorship , Surveys and Questionnaires , United Kingdom , Workforce
SELECTION OF CITATIONS
SEARCH DETAIL
...