Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Neurophysiol ; 38(3): 198-201, 2021 May 01.
Article in English | MEDLINE | ID: mdl-31834040

ABSTRACT

PURPOSE: The spike-wave index (SWI) is a key feature in the diagnosis of electrical status epilepticus during slow-wave sleep. Estimating the SWI manually is time-consuming and is subject to interrater and intrarater variability. Use of automated detection software would save time. Thereby, this software will consistently detect a certain EEG phenomenon as epileptiform and is not influenced by human factors. To determine noninferiority in calculating the SWI, we compared the performance of a commercially available spike detection algorithm (P13 software, Persyst Development Corporation, San Diego, CA) with human expert consensus. METHODS: The authors identified all prolonged EEG recordings for the diagnosis or follow-up of electrical status epilepticus during slow-wave sleep carried out from January to December 2018 at an epilepsy tertiary referral center. The SWI during the first 10 minutes of sleep was estimated by consensus of two human experts. This was compared with the SWI calculated by the automated spike detection algorithm using the three available sensitivity settings: "low," "medium," and "high." In the software, these sensitivity settings are denoted as perception values. RESULTS: Forty-eight EEG recordings from 44 individuals were analyzed. The SWIs estimated by human experts did not differ from the SWIs calculated by the automated spike detection algorithm in the "low" perception mode (P = 0.67). The SWIs calculated in the "medium" and "high" perception settings were, however, significantly higher than the human expert estimated SWIs (both P < 0.001). CONCLUSIONS: Automated spike detection (P13) is a useful tool in determining SWI, especially when using the "low" sensitivity setting. Using such automated detection tools may save time, especially when reviewing larger epochs.


Subject(s)
Algorithms , Electroencephalography/methods , Signal Processing, Computer-Assisted , Software , Status Epilepticus/diagnosis , Child , Child, Preschool , Female , Humans , Male , Sleep/physiology
2.
Seizure ; 80: 96-99, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32554293

ABSTRACT

PURPOSE: Complete visual review of prolonged video-EEG recordings at an EMU (Epilepsy Monitoring Unit) is time consuming and can cause problems in times of paucity of educated personnel. In this study we aimed to show non inferiority for electroclinical diagnosis using sampled review in combination with EEG analysis softreferware (P13 software, Persyst Corporation), in comparison to complete visual review. METHOD: Fifty prolonged video-EEG recordings in adults were prospectively evaluated using sampled visual EEG review in combination with automated detection software of the complete EEG record. Visually assessed samples consisted of one hour during wakefulness, one hour during sleep, half an hour of wakefulness after wake-up and all clinical events marked by the individual and/or nurses. The final electro-clinical diagnosis of this new review approach was compared with the electro-clinical diagnosis after complete visual review as presently used. RESULTS: The electro-clinical diagnosis based on sampled visual review combined with automated detection software did not differ from the diagnosis based on complete visual review. Furthermore, the detection software was able to detect all records containing epileptiform abnormalities and epileptic seizures. CONCLUSION: Sampled visual review in combination with automated detection using Persyst 13 is non-inferior to complete visual review for electroclinical diagnosis of prolonged video-EEG at an EMU setting, which makes this approach promising.


Subject(s)
Dromaiidae , Epilepsy , Adult , Animals , Electroencephalography , Epilepsy/diagnosis , Humans , Seizures , Software
SELECTION OF CITATIONS
SEARCH DETAIL
...