Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Cardiovasc Ultrasound ; 22(1): 3, 2024 Jan 16.
Article in English | MEDLINE | ID: mdl-38229189

ABSTRACT

BACKGROUND: Swine are frequently used as animal model for cardiovascular research, especially in terms of representativity of human anatomy and physiology. Reference values for the most common species used in research are important for planning and execution of animal testing. Transesophageal echocardiography is the gold standard for intraoperative imaging, but can be technically challenging in swine. Its predecessor, epicardial echocardiography (EE), is a simple and fast intraoperative imaging technique, which allows comprehensive and goal-directed assessment. However, there are few echocardiographic studies describing echocardiographic parameters in juvenile swine, none of them using EE. Therefore, in this study, we provide a comprehensive dataset on multiple geometric and functional echocardiographic parameters, as well as basic hemodynamic parameters in swine using EE. METHODS: The data collection was performed during animal testing in ten female swine (German Landrace, 104.4 ± 13.0 kg) before left ventricular assist device implantation. Hemodynamic data was recorded continuously, before and during EE. The herein described echocardiographic measurements were acquired according to a standardized protocol, encompassing apical, left ventricular short axis and long axis as well as epiaortic windows. In total, 50 echocardiographic parameters and 10 hemodynamic parameters were assessed. RESULTS: Epicardial echocardiography was successfully performed in all animals, with a median screening time of 14 min (interquartile range 11-18 min). Referring to left ventricular function, ejection fraction was 51.6 ± 5.9% and 51.2 ± 6.2% using the Teichholz and Simpson methods, respectively. Calculated ventricular mass was 301.1 ± 64.0 g, as the left ventricular end-systolic and end-diastolic diameters were 35.3 ± 2.5 mm and 48.2 ± 3.5 mm, respectively. The mean heart rate was 103 ± 28 bpm, mean arterial pressure was 101 ± 20 mmHg and mean flow at the common carotid artery was 627 ± 203 mL/min. CONCLUSION: Epicardial echocardiography allows comprehensive assessment of most common echocardiographic parameters. Compared to humans, there are important differences in swine with respect to ventricular mass, size and wall thickness, especially in the right heart. Most hemodynamic parameters were comparable between swine and humans. This data supports study planning, animal and device selection, reinforcing the three R principles in animal research.


Subject(s)
Echocardiography , Ventricular Function, Left , Humans , Female , Animals , Swine , Ventricular Function, Left/physiology , Echocardiography/methods , Hemodynamics , Heart Ventricles/diagnostic imaging
2.
Health Sci Rep ; 7(1): e1777, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38186934

ABSTRACT

Background: Perioperative echocardiography is of paramount importance during cardiac surgery. Nonetheless, in the experimental large-animal setting, it might be challenging obtaining optimal imaging when using conventional imaging acquisition techniques, such as transthoracic and transesophageal screenings. Open-chest surgery allows epicardial echocardiographic assessment with direct contact between probe and heart, thus providing superior quality. Standard protocols regarding the use of epicardial ultrasound in swine for research purposes are lacking. Methods: Epicardial echocardiography was performed in 10 female German Landrace pigs undergoing cardiac surgery. A structured and comprehensive protocol for epicardial echocardiography was elaborated including apical, ventricular long and short axis, as well as epiaortic planes. All experiments were approved by the local board for animal welfare and conducted in accordance with the German animal protection law (TierSchG) and the ARRIVE guidelines. Conclusions: Systematic protocols using epicardial echocardiography may serve as an additional tool to assess cardiac dimensions and function in experimental scenarios with swine models.

3.
BMC Vet Res ; 19(1): 212, 2023 Oct 18.
Article in English | MEDLINE | ID: mdl-37853424

ABSTRACT

BACKGROUND: Anatomic anomalies in the ascending aorta may impair the implantation and testing of cardiovascular devices in humans and animal models. CASE PRESENTATION: We present the rare case of an intra-aortic band in a German Landrace pig. During terminal animal testing, the band hindered the implantation of a left ventricular assist device (LVAD) with transventricular outflow graft across the aortic valve. After lower partial sternotomy, epicardial echocardiography displayed an intraluminal echogenic structure at the sinotubular junction causing unspecific flow turbulences. Under cardiopulmonary bypass, coring of the left ventricular apex was performed. Due to strong resistance in the proximal aorta, accurate positioning of the transventricular LVAD outflow graft was impossible. After euthanasia, necropsy revealed a fibrous band located at the sinotubular junction, dividing the lumen of the ascending aorta. CONCLUSIONS: The occurrence of an intra-aortic band represents an extremely rare case of a most likely congenital anomaly. Awareness of such anomalies is important for planning and performing animal testing. Perioperative echocardiography may help to either remove such anomalies or allow discontinuing the procedure prior to device implantation.


Subject(s)
Aortic Valve Insufficiency , Swine Diseases , Humans , Animals , Swine , Euthanasia, Animal , Aorta/surgery , Aorta, Thoracic , Aortic Valve Insufficiency/veterinary , Models, Animal
4.
Schizophr Res ; 172(1-3): 78-85, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26876312

ABSTRACT

Although schizophrenia (SZ) and bipolar disorder (BD) share some clinical features such as psychotic symptoms and cognitive dysfunctions, little is known about possible pathophysiological similarities between both diseases. Therefore, we investigated the potential topographical overlap and segregation of cortical thickness abnormalities in SZ and BD patients. We analyzed 3D-anatomical magnetic resonance imaging datasets with the FreeSurfer 5.1.0 software to examine cortical thickness and volumes in three groups of participants: n=34 BD patients, n=32 SZ patients and n=38 healthy controls. We observed similar bilateral cortical thickness reductions in BD and SZ patients predominantly in the pars opercularis of the inferior frontal gyrus and in the anterior and posterior cingulate. We also found disease-specific cortical reductions in the orbitofrontal cortex for BD patients and in dorsal frontal and temporal areas for SZ. Furthermore, inferior frontal gyrus cortical thinning was associated with deficits in psychomotor speed and executive functioning in SZ patients and with age at onset in both groups. Our findings support the hypothesis that thinning of the frontal cortex may represent a biological feature shared by both disease groups. The associations between cognitive deficits and the reported findings in SZ and to a lesser degree in BD patients add to the functional relevance of our results. However, further studies are needed to corroborate a model of shared pathophysiological disease features across BD and SZ.


Subject(s)
Bipolar Disorder/diagnostic imaging , Cerebral Cortex/diagnostic imaging , Schizophrenia/diagnostic imaging , Adult , Bipolar Disorder/pathology , Cerebral Cortex/pathology , Female , Humans , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Male , Organ Size , Psychiatric Status Rating Scales , Schizophrenia/pathology , Software
5.
J Affect Disord ; 174: 627-35, 2015 Mar 15.
Article in English | MEDLINE | ID: mdl-25577157

ABSTRACT

OBJECTIVES: Neuroimaging studies in patients with bipolar disorder (BD) have indicated a number of structural brain changes, including reduced cortical thickness. However, the effects of the course of illness, clinical and cognitive variables on cortical thickness in BD patients have not yet been evaluated. METHODS: A total of 67 individuals (32 patients with euthymic BD and 35 healthy and age-matched controls) underwent 3D-anatomical magnetic resonance imaging (MRI). Whole-brain cortical thickness and group differences were assessed using the Freesurfer software. Course of disease variables, clinical and cognitive parameters were correlated with cortical thickness measures. RESULTS: We found reduced cortical thickness in BD patients compared with controls in the frontal and temporal lobes and in several limbic areas. We also report significant associations between cortical thickness and age of disease-onset, speed of cognitive processing, executive function and depression severity in BD patients. CONCLUSIONS: Cortical thickness reduction across frontal and limbic areas is a structural correlate of affective symptom severity and cognitive impairments in BD as well of age of disease-onset. We may assume that frontal lobe structural abnormalities are present in bipolar disorder, and might lead to dysfunctional cognitive functioning. The causality and functional relevance beyond mere correlation, however, is yet to be established. Our findings encourage further longitudinal studies in BD patients and in healthy at-risk subjects in order to discern the temporal order and development of morphological changes and clinical symptoms.


Subject(s)
Age of Onset , Bipolar Disorder/pathology , Bipolar Disorder/psychology , Cognition , Executive Function , Frontal Lobe/pathology , Adult , Age Factors , Cognitive Dysfunction/psychology , Depressive Disorder/complications , Female , Frontal Lobe/physiopathology , Humans , Limbic System/pathology , Longitudinal Studies , Magnetic Resonance Imaging , Male , Middle Aged , Severity of Illness Index , Temporal Lobe/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...