Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Pharmaceutics ; 14(8)2022 Aug 22.
Article in English | MEDLINE | ID: mdl-36015375

ABSTRACT

Therapeutic drug monitoring (TDM) of tobramycin is widely performed in patients with cystic fibrosis (CF), but little is known about the value of model-informed precision dosing (MIPD) in this setting. We aim at reporting our experience with tobramycin MIPD in adult patients with CF. We analyzed data from adult patients with CF who received IV tobramycin and had model-guided TDM during the first year of implementation of MIPD. The predictive performance of a pharmacokinetic (PK) model was assessed. Observed maximal (Cmax) and minimal (Cmin) concentrations after initial dosing were compared with target values. We compared the initial doses and adjusted doses after model-based TDM, as well as renal function at the beginning and end of therapy. A total of 78 tobramycin courses were administered in 61 patients. After initial dosing set by physicians (mean, 9.2 ± 1.4 mg/kg), 68.8% of patients did not achieve the target Cmax ≥ 30 mg/L. The PK model fit the data very well, with a median absolute percentage error of 4.9%. MIPD was associated with a significant increase in tobramycin doses (p < 0.001) without significant change in renal function. Model-based dose suggestions were wellaccepted by the physicians and the expected target attainment for Cmax was 83%. To conclude, the implementation of MIPD was effective in changing prescribing practice and was not associated with nephrotoxic events in adult patients with CF.

2.
Nucl Med Commun ; 41(9): 977-985, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32796487

ABSTRACT

INTRODUTION:: [Ga]Ga-prostate specific membrane antigen (PSMA)-11 showed a clear gain in sensitivity for lesion detection in the biological recurrence of prostate cancer as compared to the standard [F]fluorocholine radiopharmaceutical. To meet the strong demand for [Ga]Ga-PSMA-11, we aimed to optimize an automated radiolabeling process by evaluating the influence of different key parameters on radiochemical purity and radiochemical yield. METHODS: The radiosynthesis of [Ga]Ga PSMA-11 was performed using a Trasis MiniAio synthesizer and a Ge/Ga GalliaPharm generator supplied by Eckert & Ziegler, Berlin, Germany. Optimized labeling parameters were evaluated by variation of sodium acetate concentrations and temperature of radiolabeling as well as the purification process. RESULTS: For each condition tested, radiochemical purity was higher than 99% in the final vial without batch failure, indicating a robust and fast radiosynthesis process. Radiosynthesis without the solid phase extraction purification process at room temperature in less than 5 min resulted in a radiolabeling efficiency of over 99% and remained stable at least 4 h without manual processing to limit operator radiation exposure. CONCLUSION: The procedure was completely automated and provided a high radiochemical yield. It can be performed several times a day, facilitating the clinical demand of this radiopharmaceutical.


Subject(s)
Edetic Acid/analogs & derivatives , Hot Temperature , Oligopeptides/chemistry , Oligopeptides/chemical synthesis , Radiochemistry/methods , Edetic Acid/chemical synthesis , Edetic Acid/chemistry , Edetic Acid/isolation & purification , Gallium Isotopes , Gallium Radioisotopes , Isotope Labeling , Oligopeptides/isolation & purification , Radiochemistry/instrumentation , Sodium Acetate/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...