Mol Imaging Biol ; 17(5): 620-4, 2015 Oct.
Article in English | MEDLINE | ID: mdl-25693723

ABSTRACT

PURPOSE: The purpose of the study was to define reference ranges for quantitative parameters in [(99m)Tc]mercaptoacetyltriglycerine ([(99m)Tc]MAG3) renography to assist interpretation in a semi-automated (Xeleris, GE) compared to a manual (Picker, Odyssey) software package. PROCEDURES: Forty-eight subjects approved for renal donation were evaluated with [(99m)Tc]MAG3 renography using both the Xeleris and the Picker software. RESULTS: Reference ranges for the two software were comparable regarding the relative function of the two kidneys (the split function, SF) and the residual activities (RA). The time to peak whole-kidney activities (T max whole-kidney) was more dependent on the type of software. Using Bland-Altman limits, we found good and acceptable agreement between the two methods. CONCLUSIONS: We found good correlation between renography results using the Xeleris and Picker software packages. However, software-specific reference ranges are needed.


Subject(s)
Image Interpretation, Computer-Assisted/methods , Kidney/diagnostic imaging , Radioisotope Renography/methods , Software , Technetium Tc 99m Mertiatide/therapeutic use , Adult , Aged , Female , Humans , Male , Middle Aged , Radioisotope Renography/standards , Reference Values , Young Adult