Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Language
Publication year range
1.
Rev. cuba. med ; 62(4)dic. 2023.
Article in Spanish | LILACS, CUMED | ID: biblio-1550895

ABSTRACT

Introducción: Las complicaciones asociadas al procedimiento de colocación de un dispositivo de oclusión septal se presentan en menos del 10 por ciento de los casos. La embolización requiere de cirugía cardíaca, por lo que se incrementa el riesgo de la mortalidad. Objetivo: Presentar el caso en una paciente con comunicación interventricular e hipertensión pulmonar severa que se le retiró el dispositivo de oclusión septal transcateterismo. Presentación de caso: Se presentó una mujer de 24 años de edad con comunicación interventricular, insuficiencia cardíaca (New York Heart Association) clase IV e hipertensión pulmonar tipo 2, que se programó para la colocación de dispositivo de oclusión septal, sin embargo, presentó fallo en la colocación del dispositivo y defecto residual de 7 mm, por lo que se realizó el retiro de este 48 h después sin presentar complicaciones. Conclusiones: Aunque el cierre transcateterismo de la comunicación interventricular es una alternativa segura y efectiva a la cirugía, no está exento de complicaciones. En caso de translocación del dispositivo de oclusión septal este debe ser retirado durante el mismo procedimiento, ya que el riesgo de embolización es elevado y en caso de presentarse, el riesgo de muerte se incrementa(AU)


Introduction: Complications associated with the placement procedure of a septal occlusion device occur in less than 10percent of cases. Embolization requires cardiac surgery, which increases the risk of mortality. Objective: To report the case of a patient with ventricular septal defect and severe pulmonary hypertension who had the transcatheter septal occlusion device removed. Case report: We report the case report of a 24-year-old woman with ventricular septal defect, heart failure (New York Heart Association) class IV and type 2 pulmonary hypertension. She was scheduled for placement of a septal occlusion device, however, the placement of the device failed and had a residual defect of 7 mm, so the placement was removed 48 hours later without complications. Conclusions: Although transcatheter closure of the ventricular septal defect is a safe and effective alternative to surgery, it is not free of complications. In case of translocation of the septal occlusion device, it must be removed during the same procedure, since the risk of embolization is high and if it occurs, the risk of death increases(AU)


Subject(s)
Humans , Male , Female , Septal Occluder Device/adverse effects , Heart Septal Defects, Ventricular/surgery
2.
Rev Med Inst Mex Seguro Soc ; 61(2): 245-250, 2023 Mar 01.
Article in Spanish | MEDLINE | ID: mdl-37207311

ABSTRACT

Background: Dyslipidemia is a risk factor for the development of atherosclerosis and ischemic heart disease. Statins are safe drugs that are part of the routine treatment in patients with Acute Myocardial Infarction (AMI), however, rhabdomyolysis associated with severe myonecrosis due to statins can occur and associated complications such as acute kidney injury increase mortality. The main objective of this article is to report the case of a critically ill patient with AMI who presented severe statin-associated rhabdomyolysis documented with muscle biopsy. Description of the case: A 54-year-old man who presented with AMI, cardiogenic shock, and cardiorespiratory arrest requiring cardiopulmonary resuscitation, fibrinolysis, and successful salvage coronary angiography. However, he presented severe rhabdomyolysis associated with atorvastatin that required suspension of the drug and multi-organ support in a Coronary Care Unit. Conclusions: The prevalence of statin-associated rhabdomyolysis is low, however, the late elevation of CPK above 10 times its upper normal value in those patients with successful percutaneous coronary angiography should promptly draw attention, generate a diagnostic approach towards non-traumatic acquired causes of rhabdomyolysis and assess the suspension of statins.


Introducción: la dislipidemia es un factor de riesgo para el desarrollo de ateroesclerosis y cardiopatía isquémica. Las estatinas son fármacos seguros que forman parte del tratamiento de rutina en el paciente con infarto agudo de miocardio (IAM). Sin embargo, la rabdomiólisis asociada a mionecrosis severa por estatinas puede presentarse y las complicaciones asociadas como la lesión renal aguda incrementan la mortalidad. El objetivo principal de este artículo es reportar el caso de un paciente críticamente enfermo con IAM que presentó rabdomiólisis severa asociada a estatinas documentada con biopsia muscular. Caso clínico: hombre de 54 años que presentó IAM, choque cardiogénico y paro cardiorrespiratorio, que ameritó reanimación cardiopulmonar, fibrinólisis y angiografía coronaria de rescate exitosa. Sin embargo, presentó rabdomiólisis severa asociada a atorvastatina que requirió de suspensión del fármaco y soporte multiorgánico en una unidad de cuidados coronarios. Conclusiones: la prevalencia de la rabdomiólisis asociada a estatinas es baja, sin embargo, la elevación tardía de la CPK por arriba de 10 veces su valor superior normal en aquellos pacientes con angiografía coronaria percutánea exitosa debe llamar la atención, generar un abordaje diagnóstico hacia causas adquiridas no traumáticas de rabdomiólisis y valorar la suspensión de estatinas.


Subject(s)
Hydroxymethylglutaryl-CoA Reductase Inhibitors , Myocardial Infarction , Rhabdomyolysis , Male , Humans , Middle Aged , Atorvastatin/adverse effects , Hydroxymethylglutaryl-CoA Reductase Inhibitors/adverse effects , Risk Factors , Rhabdomyolysis/chemically induced , Rhabdomyolysis/diagnosis , Rhabdomyolysis/drug therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...