Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
J Biomed Phys Eng ; 14(1): 89-98, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38357605

ABSTRACT

Background: Despite the existing evidence indicating altered hip kinematics as well as the studies showing altered movement coordination variability in persons with patellofemoral pain (PFP), there is no study investigating the correlation between hip joint kinematic and movement coordination variability in persons with patellofemoral pain (PFP). Objective: This study aims to evaluate the correlation between peak hip adduction and variability of thigh frontal-shank transverse coordination during running in persons with PFP. Material and Methods: In this cross-sectional correlational study, kinematic data were collected from 34 females (17 with and 17 without PFP) aged 18-35 years during treadmill running at preferred and fixed speeds, each for 30 s. The continuous relative phase method was used to calculate the coordination of thigh frontal-shank transverse. To calculate the deviation phase as the variability of intersegmental coordination, the standard deviation of the ensemble continuous relative phase curve points was averaged. The parameters of interest were peak hip adduction and coordination variability of thigh frontal-shank transverse. The Pearson Correlation Coefficient (r) was used to calculate the correlation between the variables. Results: The Pearson correlation coefficient showed a significant negative correlation between the peak hip adduction angle and variability of thigh frontal- shank transverse during running at both fixed (r=-0.553, P<0.05) and preferred (r=-0.660, P<0.01) speeds in persons with PFP while the control group showed a small nonsignificant correlation (r<0.29, P>0.05). Conclusion: The results indicated that greater adduction of the hip joint in persons with PFP during running is contributed to lesser variability of thigh frontal-shank transverse.

2.
PLoS One ; 18(8): e0288287, 2023.
Article in English | MEDLINE | ID: mdl-37594963

ABSTRACT

Various atomic and nuclear methods use hard (high-energy) X-rays to detect elements. The current study aims to investigate the hard X-ray production rate via high-energy proton beam irradiation of various materials. For which, appropriate conditions for producing X-rays were established. The MCNPX code, based on the Monte Carlo method, was used for simulation. Protons with energies up to 1650 MeV were irradiated on various materials such as carbon, lithium, lead, nickel, salt, and soil, where the resulting X-ray spectra were extracted. The production of X-rays in lead was observed to increase 16 times, with the gain reaching 0.18 as the proton energy increases from 100 MeV to 1650 MeV. Comparatively, salt is a good candidate among the lightweight elements to produce X-rays at a low proton energy of 30 MeV with a production gain of 0.03. Therefore, it is suggested to irradiate the NaCl target with 30 MeV proton to produce X-rays in the 0-2 MeV range.


Subject(s)
Protons , Sodium Chloride , X-Rays , Radiography , Sodium Chloride, Dietary
3.
Phys Eng Sci Med ; 46(3): 1023-1032, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37219796

ABSTRACT

Neutrons can be generated in medical linear accelerators (Linac) due to the interaction of high-energy photons (> 10 MeV) with the components of the accelerator head. The generated photoneutrons may penetrate the treatment room if a suitable neutron shield is not used. This causes a biological risk to the patient and occupational workers. The use of appropriate materials in the barriers surrounding the bunker may be effective in preventing the transmission of neutrons from the treatment room to the outside. In addition, neutrons are present in the treatment room due to leakage in the Linac's head. This study aims to reduce the transmission of neutrons from the treatment room by using graphene/hexagonal boron nitride (h-BN) metamaterial as a neutron shielding material. MCNPX code was used to model three layers of graphene/h-BN metamaterial around the target and other components of the linac, and to investigate its effect on the photon spectrum and photoneutrons. Results indicate that the first layer of a graphene/h-BN metamaterial shield around the target improves photon spectrum quality at low energies, whereas the second and third layers have no significant effect. Regarding neutrons, three layers of the metamaterial results in a 50% reduction in the number of neutrons in the air within the treatment room.


Subject(s)
Graphite , Humans , Monte Carlo Method , Neutrons , Particle Accelerators
4.
J Appl Biomech ; 39(1): 54-61, 2023 Feb 01.
Article in English | MEDLINE | ID: mdl-36649715

ABSTRACT

Left-right differential erector spinae (ES) muscle strengthening is required to correct ES muscle imbalances. The objective was to test the effect of 6 body positions on the differential activation of the ES muscles. In 14 able-bodied young women, using a surface electromyography system, the bilateral ES muscles activity at the third lumbar (ESL3) and the 10th (EST10) and 6th (EST6) thoracic vertebral levels was measured with the contralateral arm and leg lifted in the prone and quadruped conditions and with a single arm lifted in the quadruped position. Results showed that the activity of the ESL3 was symmetrical (P > .05) and significantly smaller than that of the thoracic ES muscles in all body positions (P < .01). The EST10 and EST6 were differentially activated in all tests (P < .001). Besides, the differential activation was higher in the contralateral-arm and -leg lift in the quadruped position than in the other positions. In conclusion, contralateral-arm and -leg lift and single-arm lift in the quadruped and prone positions are capable of differentially activating the ES muscles on one side more than the other side. Further studies are recommended to examine the effectiveness of these exercises on the correction of ES muscle imbalances in clinical populations.


Subject(s)
Exercise , Posture , Humans , Female , Posture/physiology , Electromyography/methods , Exercise Therapy , Muscles/physiology , Muscle, Skeletal/physiology
5.
Materials (Basel) ; 15(19)2022 Sep 26.
Article in English | MEDLINE | ID: mdl-36234009

ABSTRACT

In this paper, graphene/h-BN metamaterial was investigated as a new neutron radiation shielding (NRS) material by Monte Carlo N-Particle X version (MCNPX) Transport Code. The graphene/h-BN metamaterial are capable of both thermal and fast neutron moderator and neutron absorber process. The constituent phases in graphene/h-BN metamaterial are chosen to be hexagonal boron nitride (h-BN) and graphene. The introduced target was irradiated by an Am-Be neutron source with an energy spectrum of 100 keV to 15 MeV in a Monte Carlo simulation input file. The resulting current transmission rate (CTR) was investigated by the MCNPX code. Due to concrete's widespread use as a radiation shielding material, the results of this design were also compared with concrete targets. The results show a significant increase in NRS compared to concrete. Therefore, metamaterial with constituent phase's graphene/h-BN can be a suitable alternative to concrete for NRS.

6.
Appl Radiat Isot ; 187: 110344, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35764003

ABSTRACT

In this paper, simulation of a gas micro-strip detector by using the MCNPX code, the feasibility of alpha spectroscopy for radon and its progeny has been investigated. Initially, for the verification of the code, the range of alpha particles released from 222Rn gas in the air has been obtained in the standard condition, which is consistent with the experimental results. Subsequently, the energy loss per unit path length, range of alpha particles and radon progeny was measured, then the relationship between the range, the energy and the air pressure has been achieved. Finally, the simulation results have been compared with the results of the particle range relationship, pressure and energy, and the radon spectroscopy has been performed with the studied detector. The comparison of the spectrum obtained with the simulated micro-strip detector and the experimental results shows that the introduced micro-strip detector, in addition to the ability to measure radon and daughters, also has the ability to extract the spectrum from it.


Subject(s)
Air Pollutants, Radioactive , Radiation Monitoring , Radon , Air Pollutants, Radioactive/analysis , Radiation Monitoring/methods , Radon/analysis , Radon Daughters/analysis , Spectrum Analysis
7.
J Orthop Surg Res ; 17(1): 250, 2022 May 03.
Article in English | MEDLINE | ID: mdl-35505440

ABSTRACT

BACKGROUND: Anterior cruciate ligament plays a significant role in knee joint stability. It is claimed that the incidence of knee osteoarthritis increases in individuals with anterior cruciate ligament (ACL) rupture. The aim of this study was to evaluate the knee joints reaction force in ACL rupture group compared to normal subjects. METHOD: Fifteen patients with acute ACL rupture and 15 healthy subjects participated in this study. The ground reaction force (GRF) and kinematic data were collected at a sampling rate of 120 Hz during level-ground walking. Spatiotemporal parameters, joint angles, muscle forces and moments, and joint reaction force (JRF) of lower extremity were analyzed by OpenSIM software. RESULTS: The hip, knee and ankle joints reaction force at loading response and push-off intervals of the stance phase during walking was significantly higher in individuals with ACL rupture compared to healthy controls (p value < 0.05). Walking velocity (p value < 0.001), knee (p value = 0.065) and ankle (p value = 0.001) range of motion in the sagittal plane were significantly lower in the patients with ACL rupture compared to healthy subjects. The mean value of vertical GRF in the mid-stance, the peak of the hip adduction moment in loading response and push-off phases, the hip abductor, knee flexor and vastus intermedius part of quadriceps muscle forces were significantly higher compared to healthy subjects (p < 0.05) while vastus medialis and vastus lateralis produced significantly lower force (p < 0.001). CONCLUSIONS: Based on results of this study, lower limb JRF was higher in those with ACL rupture compared to healthy subjects may be due to the compensatory mechanisms used by this group of subjects. An increase in knee JRF in patients with ACL rupture may be the reason for the high incidence of knee OA.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament , Anterior Cruciate Ligament/physiology , Gait/physiology , Humans , Knee Joint/physiology , Walking/physiology
8.
Gait Posture ; 89: 80-85, 2021 09.
Article in English | MEDLINE | ID: mdl-34246176

ABSTRACT

BACKGROUND: Females are two times more likely to develop patellofemoral pain (PFP) than males. Abnormal trunk and pelvis kinematics are thought to contribute to the pathomechanics of this condition. However, there is a scarcity of evidence investigating proximal segments kinematics in females with PFP. RESEARCH QUESTION: The purpose of this study was to investigate whether females with PFP demonstrate altered trunk, pelvis, and knee joint kinematics compared with healthy controls during running. METHODS: Thirty-four females (17 PFP, 17 controls) underwent a 3-dimensional motion analysis during treadmill running at preferred and fixed speeds, each trial for 30 s. Variables of interest included magnitudes of peak angles for trunk (forward flexion, ipsilateral trunk lean), pelvis (anterior tilt, contralateral drop), knee (flexion, valgus, internal rotation), range of motion (RoM) of trunk and pelvis in sagittal and frontal planes and RoM of knee joint in the three cardinal planes of motion. Kinematic data were compared between groups using mixed model repeated measure analysis of variance with the trial as the repeated measure. RESULTS: The PFP group displayed significantly less pelvis frontal plane RoM, greater knee frontal plane RoM, and less knee sagittal plane RoM during running compared with controls, irrespective of running trial. No differences were found in peak kinematic variables between PFP and healthy groups. SIGNIFICANCE: These results may suggest a rigid stabilization strategy at the pelvis, which the body has adapted to prevent further frontal plane knee malalignment. Less knee sagittal plane RoM may be indicative of another protective strategy in the PFP group to avoid patellofemoral joint reaction force. Clinical assessments and rehabilitative treatments may benefit from considering a global program with focus on pelvis kinematics in addition to the knee joint in females with PFP.


Subject(s)
Patellofemoral Pain Syndrome , Running , Biomechanical Phenomena , Female , Hip Joint , Humans , Knee Joint , Male , Pain Measurement , Pelvis
SELECTION OF CITATIONS
SEARCH DETAIL
...