Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Assoc Off Anal Chem ; 67(5): 942-5, 1984.
Article in English | MEDLINE | ID: mdl-6501160

ABSTRACT

Two can leak tests were compared by 7 collaborators. In the helium leak test, pressurized helium is applied to the outside of the container, and a headspace gas sample from the can is then analyzed for the presence of helium. The vacuum test is described in the Bacteriological Analytical Manual. Ninety No. 303 cans of creamed-style corn, green beans, carrots, fruit cocktail, and whole-kernel corn were shipped in 3 groups. Two groups of 30 cans had 10 dented flat cans, 5 flat controls (nondented), 10 dented swollen cans, and 5 swollen control cans (nondented). The third group had 10 dented swollen cans and 5 swollen control cans. Of 600 cans analyzed, 37 (6.2%) were deleted from the analysis because results were not available for both tests. One laboratory was constrained by scheduling to analyze 15 of 45 swollen cans. The helium leak test found 12 (13%) positives of 92 nondented swollen cans. One pressurization test yielded 7 of those 12 positives. Of the 400 dented cans sent as possible leakers, the helium test found 267 positives, and the vacuum test found 181. Five of the 7 analysts had significantly (alpha = 0.05) higher percent positive helium results. One analyst found more leakers by the vacuum leak test. Both tests found fewer positives in the swollen dented cans than in the flat dented cans. After exposure to pressurized helium, all cans with greater than 8 psi headspace pressure were positive helium leakers. The method was adopted official first action.


Subject(s)
Food Preservation , Atmospheric Pressure , Chromatography, Gas/methods , Food Contamination , Helium
2.
J Food Prot ; 42(10): 794-799, 1979 Oct.
Article in English | MEDLINE | ID: mdl-30812132

ABSTRACT

The Scharer rapid test for measuring alkaline phosphatase activity in milk and milk products was modified to include a photoelectric colorimeter in place of visual observation of color. Dairy products containing various amounts of added enzyme (3-15 µg phenol/ml or g) were prepared for analysis as per standard methods and analyzed by the rapid colorimetric test. A linear relationship was found between the percent of raw milk added and the enzyme activity with a correlation coefficient (r) range of 0.963 to 1.000. Hydrolysis of the substrate (disodium phenyl phosphate) by the surviving enzyme in different dairy products was similar. Recovery of the added enzyme varied, depending on the nature of the product. The method is quantitative, reproducible, and can be used as a rapid confirmatory procedure. Similarly, this method was applied to differentiating residual and reactivated enzyme in milk, cream and buttermilk. Compared to the Scharer rapid and the Rutgers visual methods, this test was more reliable in borderline cases because it eliminated the bias encountered in visual examination. A method was developed to analyze alkaline phosphatase in casein.

SELECTION OF CITATIONS
SEARCH DETAIL
...