Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 89
Filter
1.
J Invasive Cardiol ; 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38848130

ABSTRACT

BACKGROUND: Lesion preparation with a cutting (CB) or scoring balloon (SB) is often used in patients with in-stent restenosis (ISR). However, there are no comparative studies. METHODS: We analyzed 81 patients (CB group: n = 38; SB group: n = 43) who had a calcified ISR from November 2019 to September 2021. The primary endpoint was strategy success (less than 20% residual stenosis); the secondary endpoints were major adverse cardiovascular events during the 1-year follow-up. Quantitative coronary angiography was performed to evaluate the strategy success. RESULTS: The patients in the CB group were more likely to have a severe calcified ISR (P = .001) and multiple stent layers (P = .001). A total of 4 patients (79.0%) reached the primary endpoint. Residual stenosis greater than 20% was more common in the CB group (39.5% vs 4.7%; P = .001). In the multivariate analysis, an effect of the intervention group on the achievement of the primary endpoint could be excluded (estimate 1.06; standard error 1.07; P = .322). The time interval of stent implantation prior to CB/SB (P = .007) and severe calcified ISR (P = .009) had a negative impact on reaching the primary endpoint. During the follow-up, there were no differences in rates of cardiac death (CB 2.5% vs. SB 1.2%; P = .598), acute myocardial infarction (CB 0% vs. SB 4.9%; P = .119), and target lesion failure (CB 3.7% vs SB 12.3%; P = .074). CONCLUSIONS: In our cohort, multivariate analysis showed that lesion preparation with CB or SB must be considered equivalent in terms of angiographic results. Factors like severe calcified ISR and the time interval of prior stent implantation negatively influenced the angiographic outcome.

2.
Struct Heart ; 8(3): 100277, 2024 May.
Article in English | MEDLINE | ID: mdl-38799801

ABSTRACT

Inferior outcomes with ACURATE neo, a self-expanding transcatheter heart valve (THV) for the treatment of severe aortic stenosis, were mainly driven by higher rates of moderate/severe paravalvular leak (PVL). To overcome this limitation, the next-generation ACURATE neo2 features a 60% larger external sealing skirt. Data on long-term performance are limited; however, clinical evidence suggests improved short-term performance which is comparable to contemporary THVs. This report reviews data on short-term clinical and echocardiographic outcomes of ACURATE neo2. A PubMed search yielded 13 studies, including 5 single arm and 8 nonrandomized comparative studies with other THVs which reported in-hospital or 30-day clinical and echocardiographic outcomes. In-hospital or 30-day all-cause mortality was ≤3.3%, which is comparable to other contemporary THVs. The rates of postprocedural ≧moderate PVL ranged 0.6%-4.7%. In multicenter propensity-matched analyses, neo2 significantly reduced the rate of ≧moderate PVL compared to neo (3.5% vs. 11.3%, p < 0.01), whereas rates were comparable to Evolut Pro/Pro+ (Neo2: 2.0% vs. Pro/Pro+: 3.1%, p = 0.28) and SAPIEN 3 Ultra (Neo2: 0.6% vs. Ultra: 1.1%, p = 0.72). The rate of permanent pacemaker implantation with neo2 was consistently low (3.3%-8.6%) except in one study, and in propensity-matched analyses were significantly lower than Evolut Pro/Pro+ (6.7% vs. 16.7%, p < 0.01), and comparable to SAPIEN 3 Ultra (8.1% vs. 10.3%, p = 0.29). In conclusion, ACURATE neo2 showed better short-term performance by considerably reducing PVL compared to its predecessor, with short-term clinical and echocardiographic outcomes comparable to contemporary THVs.

3.
Struct Heart ; 8(3): 100282, 2024 May.
Article in English | MEDLINE | ID: mdl-38799808

ABSTRACT

Background: The interplay between the right ventricle and the pulmonary artery, known as right ventricular to pulmonary artery (RV-PA) coupling, is crucial for assessing right ventricular systolic function against the afterload from the pulmonary circulation. Pulmonary artery pressure levels are ideally measured by right heart catheterization. Yet, echocardiography represents the most utilized method for evaluating pulmonary artery pressure levels, albeit with limitations in accuracy. This study therefore aims to evaluate the prognostic significance of right ventricular to pulmonary artery (RV-PA) coupling expressed as tricuspid annular plane systolic excursion (TAPSE) related to systolic pulmonary artery pressure (sPAP) levels measured by right heart catheterization (TAPSE/sPAPinvasive) or estimated by transthoracic echocardiography (TAPSE/sPAPechocardiography) in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR). Methods: Using data from a bicentric registry, this study compares TAPSE/sPAPinvasive vs. TAPSE/sPAPechocardiography in predicting 1-year all-cause mortality after TAVR. Results: Among 333 patients with complete echocardiography and right heart catheterization data obtained before TAVR, their mean age was 79.8 ± 6.74 years, 39.6% were female, and general 1-year survival was 89.8%. sPAPinvasive and sPAPechocardiography showed only moderate correlation (Pearson correlation coefficient R: 0.53, p value: <0.0001). TAPSE/sPAPinvasive was superior to TAPSE/sPAPechocardiography in predicting 1-year all-cause mortality after TAVR (area under the curve: 0.662 vs. 0.569, p value: 0.025). Patients with reduced TAPSE/sPAPinvasive levels (< 0.365 mm/mmHg) evidenced significantly lower 1-year survival rates than patients with preserved TAPSE/sPAPinvasive levels (81.8 vs. 93.6%, p value: 0.001; hazard ratio for 1-year mortality: 3.09 [95% confidence interval: 1.55-6.17]). Echocardiographic follow-up data revealed that patients with reduced RV-PA coupling suffer from persistent right ventricular dysfunction (TAPSE: 16.6 ± 4.05 mm vs. 21.6 ± 4.81 mm in patients with preserved RV-PA coupling) and severe tricuspid regurgitation (diagnosed in 19.7 vs. 6.58% in patients with preserved RV-PA coupling). Conclusions: RV-PA coupling expressed as TAPSE/sPAPinvasive can refine stratification of severe aortic stenosis patients into low-risk and high-risk cohorts for mortality after TAVR. Moreover, it can help to anticipate persistent extra-aortic valve cardiac damage, which will demand further treatment.

4.
Article in English | MEDLINE | ID: mdl-38749449

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: To identify the incidence, predictors, and clinical outcomes of PVR following TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with severe Sievers type 1 BAV stenosis undergoing TAVR with current generation transcatheter heart valves (THVs) in 24 international centres were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAE), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%): mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were larger virtual raphe ring (VRR) perimeter (ORadj 1.07, 95% CI 1.02-1.13), severe annular or left ventricular outflow tract (LVOT) calcification (ORadj 5.21, 95% CI 1.45-18.77), self-expanding valve (ORadj 9.01, 95% CI 2.09-38.86), and intentional supra-annular THV positioning (ORadj 3.31, 95% CI 1.04-10.54). At a median follow-up of 1.3 [IQR 0.5-2.4] years, moderate or severe PVR was associated with an increased risk of MAE (HRadj 2.52, 95% CI 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAE during follow-up.

5.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Article in English | MEDLINE | ID: mdl-38506737

ABSTRACT

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Subject(s)
Aortic Valve Insufficiency , Bioprosthesis , Coronary Occlusion , Transcatheter Aortic Valve Replacement , Humans , Catheters , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Heart Valves , Registries , Transcatheter Aortic Valve Replacement/adverse effects
7.
Clin Res Cardiol ; 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38483633

ABSTRACT

BACKGROUND: In the PREPARE-CALC trial, severely calcified lesion preparation with rotational atherectomy (RA) before biodegradable polymer sirolimus-eluting stent (SES) implantation demonstrated higher procedural success and comparable rates of acute lumen gain and late lumen loss compared to modified balloons (MB) (scoring/cutting). We aimed to analyze the 5-year outcomes of both lesion preparation strategies. METHODS: PREPARE-CALC randomly assigned 200 patients 1:1 to MB or RA, followed by SES implantation. The principal endpoint of the current analysis was target vessel failure (TVF) at 5 years. RESULTS: At 5 years, MB had comparable rates of TVF to RA (19% vs. 21%, HR 1.14, 95% CI 0.60-2.16, p = 0.687). Subgroup analysis showed a lesion length treatment interaction, favoring MB for short lesions and RA for long ones (p for interaction = 0.042). Target lesion revascularization (TLR) was significantly less common with RA (12 vs. 3%, HR 0.28, 95% CI 0.08-0.98, p = 0.048). In a multivariate analysis, RA was independently protective against TLR (adj. HR 0.17, 95% CI 0.04-0.78, p = 0.022), while ostial lesions were associated with higher TLR independent of treatment strategy (adj. HR 11.3, 95% CI 2.98-42.6, p < 0.001). CONCLUSION: In patients with severely calcified coronary lesions, using MB or RA for lesion preparation followed by biodegradable polymer SES implantation was associated with comparable rates of TVF at 5 years. However, a significant reduction of TLR was observed after RA. PREPARE-CALC is the first randomized trial showing potential clinical advantages of RA over MB during long-term follow-up. CLINICAL TRIAL REGISTRATION: URL: https://www. CLINICALTRIALS: gov . Unique identifier: NCT02502851.

8.
Int J Cardiol ; 400: 131792, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38244892

ABSTRACT

BACKGROUND: ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice. AIM: We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV. METHODOLOGY: This is a retrospective multicentre analysis of 499 patients with severe aortic stenosis who underwent TAVI using Neo2. The comparison was done according to the performance or omission of BAV. Echocardiography and computed tomography were analysed by an independent Core Lab. Propensity score matching (PSM) was performed based on the annular diameter and AV calcium volume, which identified 84 matched pairs. RESULTS: Among the cohort included, 391 (78%) patients received BAV (BAV-yes) and 108 (22%) were not attempted (BAV-no or Direct TAVI). Patients in BAV-no cohort had smaller annular diameter (22.6 vs 23.4 mm; p < 0.001) and lower calcium volume (163 vs 581 mm3; p < 0.001) compared to BAV-yes cohort. In the matched cohort, VARC-3 device technical success was similar (95%) and all other outcome measures were statistically comparable between cohorts. CONCLUSION: Direct TAVI using ACURATEneo2 without pre-TAVI balloon aortic valvuloplasty in patients with mild or less valve calcifications might be feasible and associated with comparable early outcomes compared to patients with similar anatomical features undergoing systematic balloon valvuloplasty.


Subject(s)
Aortic Valve Stenosis , Balloon Valvuloplasty , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Balloon Valvuloplasty/methods , Calcium , Treatment Outcome , Retrospective Studies , Prosthesis Design
9.
Herz ; 49(2): 156-164, 2024 Mar.
Article in German | MEDLINE | ID: mdl-38240775

ABSTRACT

Aortic valve stenosis is one of the most frequent valvular heart diseases requiring treatment in industrialized countries. The symptom onset is associated with a significantly increased mortality, so that there is a clear indication for treatment in patients with severe, symptomatic aortic valve stenosis; however, data on the optimal treatment of patients with asymptomatic aortic valve stenosis are scarce. Smaller studies in the field of cardiac surgery suggest that early surgical valve replacement is superior to a conservative approach. For this reason, the results of additional adequately powered randomized trials are awaited with great interest. In this year numerous long-term results from randomized comparisons of the two available treatment options (surgical versus transcatheter aortic valve replacement) were published, which will further guide the heart team to find the best treatment approach for each individual.


Subject(s)
Aortic Valve Stenosis , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Heart Valve Diseases/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Heart Valve Prosthesis Implantation/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Treatment Outcome , Risk Factors
10.
JACC Cardiovasc Interv ; 17(1): 1-13, 2024 Jan 08.
Article in English | MEDLINE | ID: mdl-37902151

ABSTRACT

BACKGROUND: Treatment of patients with recurrence of in-stent restenosis (ISR) remains particularly challenging, with data and guideline recommendations for repeat percutaneous coronary intervention being scant. OBJECTIVES: The aim of this study was to investigate the long-term incidence of recurrent revascularization events after percutaneous treatment of drug-eluting stent (DES) ISR. METHODS: In this post hoc analysis, 402 patients (500 lesions) assigned to plain balloon (PB), drug-coated balloon (DCB), or DES treatment in the randomized ISAR-DESIRE 3 (Efficacy Study of Paclitaxel-Eluting Balloon, -Stent vs. Plain Angioplasty for Drug-Eluting Stent Restenosis) trial were followed up over a median of 10.3 years. The primary endpoint was total repeat target lesion revascularization (R-TLR) including all, first and recurrent, events. RESULTS: At the end of follow-up, first R-TLR was required in 204 lesions, 82 in the PB group, 70 in the DCB group, and 52 in the DES group. The total number of R-TLRs was 373: 162 in the PB group, 124 in the DCB group, and 87 in the DES group. During the first year of follow-up, the risk for total R-TLR was reduced by DCB (HR: 0.36; 95% CI: 0.24-0.54) and DES (HR: 0.23; 95% CI: 0.14-0.38) treatment compared with PB treatment. After 1 year, the risk for total R-TLR was nonsignificantly reduced by DCB treatment (HR: 0.77; 95% CI: 0.51-1.16) and significantly reduced by DES treatment (HR: 0.61; 95% CI: 0.39-0.95) compared with PB treatment. Risk in the DCB and DES groups was similar during (HR: 1.54; 95% CI: 0.89-2.69) and after (HR: 1.26; 95% CI: 0.82-1.92) 1 year. CONCLUSIONS: The total number of R-TLRs over 10 years after treatment of patients with DES ISR was high. DCBs and particularly DES were able to reduce the need for both first and recurrent revascularization compared with PB treatment.


Subject(s)
Coronary Restenosis , Drug-Eluting Stents , Humans , Angioplasty, Balloon, Coronary , Coated Materials, Biocompatible , Coronary Angiography , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/therapy , Drug-Eluting Stents/adverse effects , Paclitaxel , Percutaneous Coronary Intervention , Treatment Outcome , Randomized Controlled Trials as Topic
11.
Clin Res Cardiol ; 113(2): 276-287, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37870627

ABSTRACT

OBJECTIVES: Systemic inflammatory response syndrome (SIRS) is a common finding after cardiovascular interventions. Data on the incidence of SIRS and its impact on outcome in patients undergoing transcatheter edge-to-edge mitral valve repair (MV-TEER) for mitral regurgitation (MR) is lacking. METHODS: From January 2013 to December 2020, 373 patients with moderate or severe MR undergoing MV-TEER were included. SIRS was defined as at least two of the following criteria within 48 h after the procedure: leucocyte count > 12.0 or < 4.0 × 109/l, respiratory rate > 20 breaths per minute or PaCO2 ≤ 4.3 kPa/32 mmHg, heart rate > 90 bpm and temperature > 38.0 °C or < 36.0 °C. The primary endpoint was 3-years all-cause mortality. RESULTS: SIRS was observed in 49.6% (185/373) of patients. Patients who developed SIRS presented more frequently with NYHA III/IV at baseline [SIRS: 82.4% (149/185) vs. no SIRS: 79.0% (147/188); p = 0.029]. Patients who developed SIRS spent more days on ICU (p < 0.001) and overall length of stay was longer (p < 0.001). Relevant residual MR, defined as MR ≥ III in-hospital, was present more often in patients who developed SIRS [SIRS: 11.3% (20/177) vs. no SIRS: 3.93% (7/178), p = 0.036]. At 3 years, all-cause mortality in the entire population was 33.5% (125/373) with an increased all-cause mortality in patients with SIRS compared to patients without SIRS (HR 1.49, [CI 95% 1.04, 2.13]; p = 0.0264). In the multivariate analysis development of SIRS (HR 1.479 [CI 95% 1.016, 2.154]; p = 0.041) was identified as predictor for 3-years all-cause mortality. CONCLUSIONS: SIRS is a common finding after MV-TEER occurring in approximately half of patients. SIRS after MV-TEER was associated with a longer in-hospital stay. In addition, we observed an increased 3-years all-cause mortality in patients with SIRS.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Incidence , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Systemic Inflammatory Response Syndrome/diagnosis , Systemic Inflammatory Response Syndrome/epidemiology , Systemic Inflammatory Response Syndrome/etiology , Heart Rate , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/epidemiology , Mitral Valve Insufficiency/surgery , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects
12.
Clin Res Cardiol ; 113(1): 38-47, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37115228

ABSTRACT

BACKGROUND: New-generation self-expanding transcatheter aortic heart valves (THV) were designed to overcome technical constraints of their preceding generations. We sought to compare the efficacy and safety of the self-expanding ACURATE neo2 (Neo2) versus Evolut PRO (PRO) devices. METHODS: Seven hundred nine patients undergoing transfemoral transcatheter aortic valve implantation (TAVI) with either Neo2 (n = 496) or PRO (n = 213) were included. Propensity score matching (PSM) was performed to account for differences in baseline characteristics. In-hospital and 30-day clinical outcomes were evaluated according to Valve Academic Research Consortium-3 criteria. RESULTS: Baseline characteristics were comparable between both groups after PSM (Neo2: n = 155, Evolut Pro: n = 155). Technical success rates were high in both groups (Neo2: 94.8% vs PRO: 97.4%; p = 0.239). Need for permanent pacemaker implantation was less frequent with Neo2 compared with PRO (7.5% vs 20.6%; p = 0.002), whereas major vascular complications were more frequent with Neo2 (Neo2: 11.6% vs PRO: 4.5%; p = 0.022). Intended valve performance at discharge was high in both groups without relevant differences among groups (Neo2: 97.4% vs. 95.3%; p = 0.328). CONCLUSIONS: Short-term outcomes after TAVI using latest-generation self-expanding THV were excellent, with overall low rates of adverse events. However, Neo2 was associated with lower pacemaker rates and reduced the prevalence of moderate-severe paravalvular leakage. Transprosthetic gradients after TAVI were higher with Neo2 compared with PRO.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Prosthesis Design , Treatment Outcome
13.
Article in English | MEDLINE | ID: mdl-38065713

ABSTRACT

BACKGROUND: Data on systemic inflammatory response syndrome (SIRS) after transcatheter aortic valve implantation (TAVI) are scarce and limited to small cohorts. We aimed to investigate its incidence and mid-term impact in a large cohort of TAVI patients. METHODS: From January 2018 to December 2020, 717 patients with severe aortic valve stenosis undergoing TAVI were included. SIRS was defined as fulfilling at least two of the following criteria within 48 h from the procedure: leucocyte count >12.0 or <4.0 × 109/l, respiratory rate > 20 breaths per minute or PaCO2 ≤ 4.3 kPa/32 mmHg, heart rate > 90 beats per minute and temperature > 38.0 °C or <36.0 °C. Clinical endpoints were 1-year rehospitalization for chronic heart failure (CHF) and 2-years all-cause mortality. Event rates during follow-up were calculated as Kaplan-Meier estimates. RESULTS: SIRS developed in 56.3 % (404/717) of patients after TAVI. SIRS occurred more frequently in patients with post-dilatation (SIRS 34.7 % (140/404) vs. no SIRS 23.3 % (73/313); p < 0.001) and major vascular complications (SIRS 16.1 % (65/404) vs. no SIRS 8.6 % (27/313); p = 0.004). Further, ICU days were more in patients who developed SIRS (SIRS 1.56 ± 1.50 days vs. no SIRS 1.22 ± 1.02 days; p = 0.001). At 2-years, all-cause mortality in the entire population was 23.9 %. However, there was no difference in CHF at 1-year (5.9 % vs. 4.1 %; log-rank = 0.347) nor in all-cause mortality at 2-years (22.0 % vs. 26.2 %; log-rank = 0.690) between the groups. CONCLUSIONS: SIRS is a common finding after TAVI, which may prolong hospital stay but is without effect on mortality during 2-years follow-up.

14.
Clin Res Cardiol ; 2023 Dec 19.
Article in English | MEDLINE | ID: mdl-38112745

ABSTRACT

BACKGROUND: Modified balloon angioplasty (MB) using a cutting-/scoring balloon or intravascular lithotripsy (IVL) is used in patients with in-stent restenosis (ISR). However, IVL is an off-label use in this setting. The aim of this subgroup analysis of an all-comers registry was to compare IVL to MB angioplasty in patients with ISR. METHODS: The subgroup (n = 117) included all patients with an ISR treated by MB or IVL between 2019 and 2021. Primary endpoint was strategy success (< 20% residual stenosis). The secondary endpoint was cardiac death, acute myocardial infarction (AMI) and target lesion failure/revascularization (TVR). Quantitative coronary angiography was performed in all patients. RESULTS: A total of n = 36 patients were treated by IVL and n = 81 patients by MB. No significant differences in baseline characteristics were observed between the groups. The primary endpoint was reached in 99 patients (84.6%). Patients in the IVL group had less residual stenosis (2.8% vs. 21.0%; p = 0.012). Multivariate regression analysis revealed that IVL had a significant positive effect on reaching the primary end point (Estimate 2.857; standard error (SE) 1.166; p = 0.014). During the follow-up period (450 days) there were no significant differences in rates of cardiac death (IVL n = 2 (1.7%) vs. MB n = 3 (2.6%); p = 0.643), AMI (IVL n = 2 (1.7%) vs. MB n = 4 (3.4%); p = 0.999) and TVR (IVL n = 5 (4.3%) vs. MB n = 14 (12%); p = 0.851). CONCLUSION: IVL results in a significantly lower rate of residual stenosis than MB in patients with ISR. During the long-term follow-up, no differences in rates of cardiac death, AMI or TVR were observed.

15.
Clin Res Cardiol ; 2023 Nov 06.
Article in English | MEDLINE | ID: mdl-37930402

ABSTRACT

BACKGROUND: The performance of modified balloons (namely cutting or scoring balloons) to prepare severely calcified lesions in patients undergoing percutaneous coronary intervention (PCI) remains controversial. We investigated the clinical and imaging outcomes of patients undergoing PCI assigned to modified balloon therapy to prepare severely calcified coronary lesions before stent implantation. METHODS: In this meta-analysis, we aggregated the study-level data from trials enrolling invasively treated patients who were randomly assigned to modified balloon or control therapy to prepare severely calcified lesions before stenting. The primary outcome was major adverse cardiac events (MACE), including death, myocardial infarction (MI), and repeat revascularization. The secondary outcomes included the individual components of the primary outcome, coronary perforation and final minimal stent area (MSA) as measured by intracoronary imaging. RESULTS: A total of 648 participants in six trials were allocated to modified balloon therapy (n = 335) or control therapy (semi-compliant, non-compliant, or super high-pressure balloon, n = 313). The median follow-up was 11 months. Overall, MACE occurred in 8.96% of patients assigned to a modified balloon and 12.78% of patients assigned to control therapy [risk ratio = 0.70, 95% confidence interval (CI) 0.35-1.39; P = 0.24]. There was a significant treatment effect-by-modified balloon type interaction for the outcome MACE in patients assigned to cutting balloon compared with control therapy [RR = 0.40 (0.28-0.56), P for interaction (Pint) < 0.001]. Patients treated with a modified balloon compared with control therapy showed neither a significant difference for the other clinical outcomes nor for final MSA [standardized mean difference = 0.67 (- 0.71, 2.06); P = 0.26]. CONCLUSIONS: In patients treated with PCI for severely calcific coronary artery disease a strategy of lesion preparation with a modified balloon before stenting does not improve clinical or imaging outcomes compared with control therapy. The different performance of cutting and scoring balloons warrants further investigation.

16.
Catheter Cardiovasc Interv ; 102(7): 1301-1310, 2023 12.
Article in English | MEDLINE | ID: mdl-37877190

ABSTRACT

BACKGROUND: Permanent pacemaker implantation (PPI) remains a relevant complication after transcatheter aortic valve implantation (TAVI) and its impact on outcome remains controversial. AIMS: This study aimed to analyze the effects of implantation depth on PPI at 30 days and assess its impact on outcome with the balloon-expandable Sapien 3 (S3) prosthesis. METHODS: Between 2014 and 2018, 849 patients without previous pacemaker undergoing transfemoral TAVI with the S3 were included. Prosthesis implantation depth was measured and divided into Quintiles. An ordinal logistic regression was used to assess its association with PPI, while a multivariate logistic regression was performed to identify predictors of PPI. Survival analyses were performed with the Kaplan-Meier method and a multivariable Cox regression was performed to ascertain the impact of PPI on mortality. RESULTS: Overall, incidence of PPI at 30 days was 9.7%. Implantation depth decreased consistently from a median of 6.7 mm [5.55-8.00] in 2014 to 2.7 mm [2.30-3.50] in 2018 (p < 0.001). When considering Quintiles of implantation depth, incidence of PPI was significantly higher in upper Quintiles and risk for PPI was significantly lower for the 1. Quintile compared to the 5. Quintile (OR: 0.34, 95% CI: [0.16-0.73]; p = 0.003). In the adjusted multivariable logistic regression implantation depth persisted ad independent predictor of PPI at 30 days. Patients requiring PPI at 30 days displayed significantly higher mortality at 4 years compared to patients without PPI (49.5% vs. 40.0%; log-rank = 0.022). In a multivariate analysis, increased logistic EuroScore, diabetes mellitus, and history of atrial fibrillation, were independent predictors of all-cause mortality at 2 years. CONCLUSIONS: Higher prosthesis implantation relative to the virtual aortic annulus was significantly associated with reduced risk for PPI at 30 days. Patients with PPI at 30 days exhibited higher mortality during follow-up, however, only logistic EuroScore, diabetes mellitus, and history of atrial fibrillation were identified as independent predictors of mortality at 2 years.


Subject(s)
Aortic Valve Stenosis , Atrial Fibrillation , Diabetes Mellitus , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Atrial Fibrillation/etiology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Heart Valve Prosthesis/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Risk Factors
17.
EuroIntervention ; 19(7): 589-599, 2023 Sep 18.
Article in English | MEDLINE | ID: mdl-37436190

ABSTRACT

BACKGROUND: The optimal timing to perform percutaneous coronary interventions (PCI) in transcatheter aortic valve implantation (TAVI) patients remains unknown. AIMS: We sought to compare different PCI timing strategies in TAVI patients. METHODS: The REVASC-TAVI registry is an international registry including patients undergoing TAVI with significant, stable coronary artery disease (CAD) at preprocedural workup. In this analysis, patients scheduled to undergo PCI before, after or concomitantly with TAVI were included. The main endpoints were all-cause death and a composite of all-cause death, stroke, myocardial infarction (MI) or rehospitalisation for congestive heart failure (CHF) at 2 years. Outcomes were adjusted using the inverse probability treatment weighting (IPTW) method. RESULTS: A total of 1,603 patients were included. PCI was performed before, after or concomitantly with TAVI in 65.6% (n=1,052), 9.8% (n=157) or 24.6% (n=394), respectively. At 2 years, all-cause death was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (6.8% vs 20.1% vs 20.6%; p<0.001). Likewise, the composite endpoint was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (17.4% vs 30.4% vs 30.0%; p=0.003). Results were confirmed at landmark analyses considering events from 0 to 30 days and from 31 to 720 days. CONCLUSIONS: In patients with severe aortic stenosis and stable coronary artery disease scheduled for TAVI, performance of PCI after TAVI seems to be associated with improved 2-year clinical outcomes compared with other revascularisation timing strategies. These results need to be confirmed in randomised clinical trials.


Subject(s)
Aortic Valve Stenosis , Coronary Artery Disease , Myocardial Infarction , Percutaneous Coronary Intervention , Transcatheter Aortic Valve Replacement , Humans , Coronary Artery Disease/surgery , Coronary Artery Disease/complications , Percutaneous Coronary Intervention/methods , Aortic Valve Stenosis/therapy , Myocardial Infarction/complications , Treatment Outcome , Aortic Valve/surgery , Risk Factors
18.
Am Heart J ; 264: 114-122, 2023 10.
Article in English | MEDLINE | ID: mdl-37315878

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) was established as a standard treatment for high-operative risk patients with severe aortic stenosis (AS). Although coronary artery disease (CAD) often coexists with AS, clinical and angiographic evaluations of stenosis severity are unreliable in this specific setting. To provide precise risk stratification of coronary lesions, combined near-infrared spectroscopy and intravascular ultrasound (NIRS-IVUS) was developed to integrate morphological and molecular information on plaque composition. However, there is a lack of evidence on the association between NIRS-IVUS derived findings such as maximum 4mm lipid core burden index (maxLCBI4mm) and clinical outcomes in AS patients undergoing TAVI. This registry aims to assess feasibility and safety of NIRS-IVUS imaging in the setting of routine pre-TAVI coronary angiography to improve assessment of CAD severity. METHODS: The registry is designed as a non-randomized, prospective, observational, multicenter cohort registry. Patients referred for TAVI with angiographic evidence of CAD receive NIRS-IVUS imaging and are followed up to 24 months. Enrolled patients are classified as NIRS-IVUS positive and NIRS-IVUS negative, respectively, based on their maxLCBI4mm to compare their clinical outcomes. The primary endpoint of the registry is major adverse cardiovascular events over a 24-month follow-up period. CONCLUSIONS: Identification of patients likely or unlikely to benefit from revascularization prior to TAVI represents an important unmet clinical need. This registry is designed to investigate whether NIRS-IVUS-derived atherosclerotic plaque characteristics can identify patients and lesions at risk for future adverse cardiovascular events after TAVI, in order to refine interventional decision-making in this challenging patient population.


Subject(s)
Coronary Artery Disease , Plaque, Atherosclerotic , Transcatheter Aortic Valve Replacement , Humans , Coronary Artery Disease/diagnosis , Coronary Artery Disease/surgery , Spectroscopy, Near-Infrared/methods , Prospective Studies , Ultrasonography, Interventional/methods , Coronary Angiography , Registries
19.
Front Cardiovasc Med ; 10: 1185422, 2023.
Article in English | MEDLINE | ID: mdl-37255702

ABSTRACT

Background: The aim of this two-center, all-comers registry was to compare the effectiveness and safety of intravascular lithotripsy (IVL) to that of modified balloon angioplasty (MB). MB angioplasty using a cutting or scoring balloon is commonly used in patients with calcified coronary arteries. IVL is a new technology for lesion preparation. This is the first study to compare MB with IVL. Methods: The cohort included all patients treated by MB angioplasty or IVL between 2019 and 2021. The primary endpoint was strategy success (<20% residual stenosis). The secondary endpoint was long-term safety outcomes [cardiac death, acute myocardial infarction (AMI), target lesion failure/revascularization (TVR)]. Quantitative coronary angiography (QCA) was performed in all patients. Primary and secondary endpoints were compared using inverse probability of treatment weighting (IPTW) for treatment effect estimation. Results: A total of n = 86 patients were treated by IVL and n = 92 patients by MB angioplasty. The primary endpoint was reached in 152 patients (85.4%). Patients in the IVL group had less residual stenosis (5.8% vs. 22.8%; p = 0.001) in QCA. Weighted multivariable regression analysis revealed that IVL had a significant positive effect on reaching the primary endpoint of strategy success [odds ratio (OR) 24.58; 95% confidence interval (95% CI) 7.40-101.86; p = 0.001]. In addition, severe calcification was shown to result in a lower probability of achieving the primary endpoint (OR 0.08; 95% CI 0.02-0.24; p = 0.001). During the follow-up period (450 days) there was no difference in cardiovascular mortality rate [IVL (n = 5) 2.8% vs. MB (n = 3) 1.7%; p = 0.129]. Patients with unstable angina at the time of the index procedure had the highest probability of cardiovascular death [hazard ratio (HR) 7.136; 95% CI 1.248-40.802; p = 0.027]. No differences were found in long-term rates of AMI (IVL 1.7% vs. MB 2.8%; p = 0.399; IVL HR 2.73; 95% CI 0.4-17.0; p = 0.281) or TVR (IVL 5.6% vs. MB 9%; p = 0.186; IVL HR 0.78; 95% CI 0.277-2.166; p = 0.626). Conclusion: IVL leads to a significantly better angiographic intervention outcome compared to MB angioplasty in our cohort. During long-term follow-up, no differences in cardiovascular mortality, rate of acute myocardial infarction, or target lesion failure/revascularization were observed.

SELECTION OF CITATIONS
SEARCH DETAIL
...