Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Minim Invasive Surg ; 24(1): 5-7, 2021 Mar 15.
Article in English | MEDLINE | ID: mdl-35601279

ABSTRACT

Laparoscopic surgery is rapidly evolving with technological advances, but there are several drawbacks. An articulating device, with freedom of a perfect 360°, is attractive as a solution to overcome the restriction of instrument movement caused by straight tools. Its usefulness or efficacy should be supported by relevant scientific evidence. However, it is sometimes difficult to prove it because the factors influencing the surgical outcomes are complex and closely related to each other.

2.
Surg Endosc ; 32(10): 4344-4350, 2018 10.
Article in English | MEDLINE | ID: mdl-29785459

ABSTRACT

BACKGROUND: Gastroduodenostomy is preferred as a method of reconstruction following distal subtotal gastrectomy. However, in initial reports on reduced-port gastrectomy, gastroduodenostomy has rarely been performed therein because of technical difficulties. The present study describes a novel intracorporeal gastroduodenostomy technique applicable during reduced-port robotic distal subtotal gastrectomy. METHODS: Data were retrospectively reviewed for cases of reduced-port (three-port) robotic distal subtotal gastrectomy with intracorporeal delta-shaped gastroduodenostomy performed from February 2016 to December 2016. The reduced-port approach used a Single-Site™ port via a 25-mm infraumbilical incision and two additional ports. We performed intracorporeal gastroduodenostomy using a 45-mm robotic or laparoscopic endolinear stapler. All staplers were inserted via a port on the left lower abdomen. RESULTS: In our initial experience with intracorporeal gastroduodenostomy, 28 consecutive patients underwent successful surgery with the technique without needing to convert to open, laparoscopic, or conventional five-port robotic surgery. Mean operation time was 201.1 min (110-282 min), and no major complications, including anastomosis-related problems, were recorded. CONCLUSIONS: Intracorporeal delta-shaped gastroduodenostomy was safely and feasibly applied during reduced-port robotic gastrectomy with acceptable operative outcomes and no major complications. Intracorporeal gastroduodenostomy should be considered during reduced-port distal subtotal gastrectomy.


Subject(s)
Duodenostomy/methods , Gastrectomy/methods , Gastroenterostomy/methods , Robotic Surgical Procedures/methods , Stomach Neoplasms/surgery , Adult , Aged , Aged, 80 and over , Anastomosis, Surgical , Conversion to Open Surgery , Duodenostomy/adverse effects , Female , Gastrectomy/adverse effects , Gastroenterostomy/adverse effects , Humans , Laparoscopy/adverse effects , Laparoscopy/methods , Male , Middle Aged , Operative Time , Postoperative Complications , Retrospective Studies , Robotic Surgical Procedures/adverse effects , Surgical Stapling
SELECTION OF CITATIONS
SEARCH DETAIL
...