Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Molecules ; 27(7)2022 Mar 23.
Article in English | MEDLINE | ID: mdl-35408472

ABSTRACT

A flow-based method for the spectrophotometric determination of chromium (VI) in recreational waters with different salinities was developed. Chromium can occur in the environment in different oxidation states with different related physiological properties. With regard to chromium, the speciation is particularly important, as the hexavalent chromium is considered to be carcinogenic. To achieve that purpose, the use of the diphenylcarbazide (DPC) selective colored reaction with the hexavalent chromium was the chosen strategy. The main objective was to develop a direct and simple spectrophotometric method that could cope with the analysis of different types of environmental waters, within different salinity ranges (fresh to marine waters). The potential interference of metal ions, that can usually be present in environmental waters, was assessed and no significant interferences were observed (<10%). For a complete Cr(VI) determination (three replicas) cycle, the corresponding reagents consumption was 75 µg of DPC, 9 mg of ethanol and 54 mg of sulfuric acid. Each cycle takes about 5 min, including the system clean-up. The limit of detection was 6.9 and 12.2 µg L−1 for waters with low and high salt content, respectively. The method was applied for the quantification of chromium (VI) in both fresh and marine water, and the results were in agreement with the reference procedure.


Subject(s)
Chromium , Water , Chromium/analysis , Diphenylcarbazide , Spectrophotometry/methods
2.
Molecules ; 25(21)2020 Oct 31.
Article in English | MEDLINE | ID: mdl-33142737

ABSTRACT

A bi-parametric sequential injection method for the determination of copper(II) and zinc(II) when present together in aqueous samples was developed. This was achieved by using a non-specific colorimetric reagent (4-(2-pyridylazo)resorcinol, PAR) together with two ion-exchange polymeric materials to discriminate between the two metal ions. A polymer inclusion membrane (PIM) and a chelating resin (Chelex 100) were the chosen materials to retain zinc(II) and copper(II), respectively. The influence of the flow system parameters, such as composition of the reagent solutions, flow rates and standard/sample volume, on the method sensitivity were studied. The interference of several common metal ions was assessed, and no significant interferences were observed (<10% signal deviation). The limits of detection were 3.1 and 5.6 µg L-1 for copper(II) and zinc(II), respectively; the dynamic working range was from 10 to 40 µg L-1 for both analytes. The newly developed sequential injection analysis (SIA) system was applied to natural waters and soil leachates, and the results were in agreement with those obtained with the reference procedure.


Subject(s)
Coloring Agents/chemistry , Copper/analysis , Polymers/chemistry , Resorcinols/chemistry , Zinc/analysis , Chelating Agents/chemistry , Colorimetry , Flow Injection Analysis , Iron/analysis , Limit of Detection , Resins, Synthetic/chemistry , Soil/chemistry , Spectrometry, Fluorescence , Water/chemistry
3.
Talanta ; 216: 120925, 2020 Aug 15.
Article in English | MEDLINE | ID: mdl-32456899

ABSTRACT

A flow-based method for the spectrophotometric determination of iron in recreational waters, both fresh and marine (variable salinity content), was developed. For that purpose, 3-hydroxy-4-pyrydinone ligand functionalized with an ether function was synthetized and used as chromogenic chelator (1-(3'-methoxypropyl)-2-methyl-3-benzyloxy-4-(1H)pyridinone - MRB13) for iron quantification. This water-soluble reagent was previously reported as a greener alternative to quantify iron, due to its low toxicity and a more environmental friendly synthesis. Furthermore, it also displayed a high affinity and specificity for iron. With the main objective of quantifying iron in a variety of water types (different matrices and iron content), two strategies were developed, one of them including on-line solid-phase extraction (SPE), and the other without resorting to a SPE process. Water matrix clean-up and iron enrichment was achieved using a nitrilotriacetic acid resin column. The potential interference of metal ions usually present in water samples was assessed and no significant interference (<10%) was observed. The limits of detection were 11 and 2.9 µg L-1 without and with SPE, respectively. For one determination (three replicates), the corresponding consumption of MRB13 is 90 µg, sodium hydroxide is 1.4 mg, and boric acid is 5.6 mg. The method was applied to certified water samples and the results were in agreement with certified values. The developed method was also applied to fresh and marine water, and recovery ratios of 103 ± 4 and 101 ± 7 without and with SPE, respectively, were achieved.

SELECTION OF CITATIONS
SEARCH DETAIL
...