1.
Luminescence ; 24(1): 10-4, 2009.
Article in English | MEDLINE | ID: mdl-18780326

ABSTRACT

In this study, a straightforward and automated pulsed flow-based procedure was developed for the chemiluminometric determination of gabapentin [1-(aminomethyl)cyclo-hexaneacetic acid], a new generation antiepileptic drug, in different formulated dosage forms. The software-controlled time-based injection method capitalizes on the decrease of the background chemiluminescence (CL) readout of the luminol-hypochlorite reaction in the presence of gabapentin. In short, gabapentin works as a hypochlorite scavenger. The analytical procedure was implemented in a multi-pumping flow network furnished with a suite of microdispensing solenoid-actuated pumps. The diaphragm-type micropumps might be configured to operate as fluid propellers, commutation units and metering injectors. A dynamic linear working range for gabapentin concentrations in the range 60-350 micromol/L was obtained, with an estimated detection limit of 40 micromol/L. The flow analyser handles about 41 injections/h and yields precise results (RSD < 2%). The miniaturized flow analyser thus has potential to be exploited for in-line monitoring of drug manufacturing within the quality assurance framework of modern pharmaceutical companies.


Subject(s)
Amines/analysis , Amines/chemistry , Cyclohexanecarboxylic Acids/analysis , Cyclohexanecarboxylic Acids/chemistry , Luminescent Measurements/instrumentation , Luminescent Measurements/methods , Pharmaceutical Preparations/chemistry , gamma-Aminobutyric Acid/analysis , gamma-Aminobutyric Acid/chemistry , Calibration , Gabapentin , Hydrogen-Ion Concentration , Time Factors
2.
Anal Chim Acta ; 600(1-2): 14-20, 2007 Sep 26.
Article in English | MEDLINE | ID: mdl-17903459

ABSTRACT

Solutions propelling devices are fundamental components of a flow-based analytical manifold. In this work different manifold configurations were implemented to evaluate the performance of multiple piezoelectric micro-pumps used as solutions insertion and propulsion devices. The micro-pumps are piezo-actuated micro-diaphragm pumps with passive check valves characterised by a small compact size and low power demands, and are able to produce reproducible flow rates of up to 4 mL min(-1). The flow rate is controlled by the frequency of the piezoelectric actuator (up to 20 Hz). As an additional feature, piezoelectric micro-pumps actuation generates a pulsed flowing stream that ensures a faster sample/reagent mixing contributing to improved reaction development. The developed flow approach was assessed in the spectrophotometric determination of gabapentin in pharmaceutical preparations upon reaction with 1,2-naphthoquinone-4-sulfonate in alkaline medium. Distinct flow manifold configurations were designed for achievement of different solutions management. Linear calibrations plots for gabapentin concentrations of up to 150 mg L(-1), with relative standard deviations of less than 1.50% (n=10) and a sample throughput of about 28 determinations per hour, were obtained.


Subject(s)
Amines/analysis , Cyclohexanecarboxylic Acids/analysis , Electronics/instrumentation , Electronics/methods , Flow Injection Analysis/methods , Spectrophotometry/methods , gamma-Aminobutyric Acid/analysis , Flow Injection Analysis/instrumentation , Gabapentin , Pharmaceutical Preparations/analysis , Spectrophotometry/instrumentation
3.
Anal Chim Acta ; 600(1-2): 21-8, 2007 Sep 26.
Article in English | MEDLINE | ID: mdl-17903460

ABSTRACT

Nowadays, the trend towards more compact, smarter and simpler devices is generally recognized as one of the most challenging aspects in the development of analytical instrumentation. Modern flow-based procedures do not escape this tendency. The level of integration and automation and the operational functionality of Multi-pumping flow systems (MPFS) would, in most of the situations, meet this requirement. The essential elements of MPFS are multiple solenoid actuated micro-pumps strategically positioned in the flow manifold, which are accountable for solutions insertion, propelling and commutation, conditioning the establishment and subsequent detection of the reaction zone. Being the only active components of the flow manifold they provide a great operational simplicity and assure a straightforward run-time control of important analytical variables. Moreover, the reduction of active components minimizes the probability of occurrence of equipment failures, malfunctions or errors. The low size and low cost of solenoid micro-pumps make them ideal tools to build up compact environmentally friendly analytical systems, which are characterized by low solutions consumptions and the minimisation of hazardous waste generation. Furthermore, the reproducible pulsed flowing stream produced by micro-pumps actuation has proven to be a valuable feature regarding sample/reagent mixing and reaction zone homogenisation.


Subject(s)
Flow Injection Analysis/instrumentation , Flow Injection Analysis/methods
4.
J Biomol Screen ; 12(6): 875-80, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17848640

ABSTRACT

Peroxynitrite anion is a reactive nitrogen species formed in vivo by the rapid, controlled diffusion reaction between nitric oxide and superoxide radicals. By reacting with several biological molecules, peroxynitrite may cause important cellular and tissue deleterious effects, which have been associated with many diseases. In this work, an automated flow-based procedure for the in vitro generation of peroxynitrite and subsequent screening of the scavenging activity of selected compounds is developed. This procedure involves a multipumping flow system (MPFS) and exploits the ability of compounds such as lipoic acid, dihydrolipoic acid, cysteine, reduced glutathione, oxidized glutathione, sulindac, and sulindac sulfone to inhibit the chemiluminescent reaction of luminol with peroxynitrite under physiological simulated conditions. Peroxynitrite was generated in the MPFS by the online reaction of acidified hydrogen peroxide with nitrite, followed by a subsequent stabilization by merging with a sodium hydroxide solution to rapidly quench the developing reaction. The pulsed flow and the timed synchronized insertion of sample and reagent solutions provided by the MPFS ensure the establishment of the reaction zone only inside the flow cell, thus allowing maximum chemiluminescence emission detection. The results obtained for the assayed compounds show that, with the exception of oxidized glutathione, all are highly potent scavengers of peroxynitrite at the studied concentrations.


Subject(s)
Drug Evaluation, Preclinical/methods , Flow Injection Analysis/methods , Free Radical Scavengers/analysis , Free Radical Scavengers/pharmacology , Peroxynitrous Acid/chemistry , Peroxynitrous Acid/metabolism , Flow Injection Analysis/instrumentation , Luminescent Measurements , Models, Biological , Pulsatile Flow , Specimen Handling
5.
Anal Bioanal Chem ; 384(4): 1019-24, 2006 Feb.
Article in English | MEDLINE | ID: mdl-16408216

ABSTRACT

A novel strategy for utilization of solid reagents in flow analysis is proposed. Establishment of diffuse and reproducible geometry enables the solid particles to be maintained in constant floating, reflux, and circulating motion inside a mini-chamber. This is efficiently accomplished with pulsed flows, a characteristic of multi-pumping flow systems. Drawbacks inherent in solid-phase packed columns, for example backpressure, preferential pathways, swelling, etc., and some limitations inherent in immobilized reagents are minimised. Spectrophotometric determination of zinc in plants was selected as an application of the technique. Dowex 1-X8 anionic resin was kept freely inside a mini-chamber. Zinc chloro-complexes were adsorbed on the moving particles and derivatization with zincon was performed after elution. Analytical figures of merit and the potential and limitations of the approach are discussed.


Subject(s)
Chromatography, Ion Exchange/instrumentation , Plants/chemistry , Spectrum Analysis/methods , Zinc/analysis
6.
Talanta ; 68(2): 351-8, 2005 Dec 15.
Article in English | MEDLINE | ID: mdl-18970329

ABSTRACT

The dual or multiple reaction interface concept, commonly associated to the distinct flow techniques, was replaced by a single interface concept, which do not no rely on the utilisation of a well-defined and compelling sample volume but only on mutual penetration of sample and reagent zones at a single reaction interface where both sample and reagent met together prior to detection. In the proposed approach basic principles of flow analysis, such as controlled dispersion and reaction zone formation, are not influenced by sample and reagent volumes but determined exclusively by the extension of the overlap of two adjoining quasi-infinite zones enhanced by multiple flow reversals and the pulsed nature of the flowing streams. The detector is positioned at the core of the flow manifold (not in the conventional terminal position), and repetitive flow reversals enable interface manipulations, including multi-detection of the entire reaction interface or the monitoring of the evolution of a pre-selected interface zone by using suitable reversal cycle times. The implementation of the developed approach was facilitated due to the configuration simplicity and operational versatility of multi-pumping flow systems. Its performance was evaluated by monitoring processes involving two or four-solution reaction interfaces.

7.
Talanta ; 64(5): 1091-8, 2004 Dec 15.
Article in English | MEDLINE | ID: mdl-18969716

ABSTRACT

Multi-pumping flow systems (MPFS) are one of the most recent developments in terms of the design, conception and implementation of continuous flow methodologies, for sample and reagent handling and for the automation of analytical procedures. Based on the utilisation of multiple solenoid micro-pumps they enable the configuring of fully automated and easily controlled and operated analytical systems since all the fundamental operations involved in carrying out a sample analysis, including sample insertion, reagent addition and signal measurement could be carried out by the same manifold component, reducing the number of system parts and minimising its control or the occurrence of mal-functions. On the other hand, micro-pumps actuation produce a pulsed flow characterised by a chaotic movement of the solutions, which contributes to a fast sample/reagent homogenisation with low axial dispersion yielding improved analytical signals. The combination of such advantageous features resulted in simple, compact, versatile, fast, low-cost analytical procedures, exhibiting low reagent and low sample consumption, reducing the production of undesirable wastes and minimising operator intervention.