Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
Sensors (Basel) ; 24(3)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38339678

ABSTRACT

The integration of artificial intelligence (AI) with Digital Twins (DTs) has emerged as a promising approach to revolutionize healthcare, particularly in terms of diagnosis and management of thoracic disorders. This study proposes a comprehensive framework, named Lung-DT, which leverages IoT sensors and AI algorithms to establish the digital representation of a patient's respiratory health. Using the YOLOv8 neural network, the Lung-DT system accurately classifies chest X-rays into five distinct categories of lung diseases, including "normal", "covid", "lung_opacity", "pneumonia", and "tuberculosis". The performance of the system was evaluated employing a chest X-ray dataset available in the literature, demonstrating average accuracy of 96.8%, precision of 92%, recall of 97%, and F1-score of 94%. The proposed Lung-DT framework offers several advantages over conventional diagnostic methods. Firstly, it enables real-time monitoring of lung health through continuous data acquisition from IoT sensors, facilitating early diagnosis and intervention. Secondly, the AI-powered classification module provides automated and objective assessments of chest X-rays, reducing dependence on subjective human interpretation. Thirdly, the twin digital representation of the patient's respiratory health allows for comprehensive analysis and correlation of multiple data streams, providing valuable insights as to personalized treatment plans. The integration of IoT sensors, AI algorithms, and DT technology within the Lung-DT system demonstrates a significant step towards improving thoracic healthcare. By enabling continuous monitoring, automated diagnosis, and comprehensive data analysis, the Lung-DT framework has enormous potential to enhance patient outcomes, reduce healthcare costs, and optimize resource allocation.


Subject(s)
Artificial Intelligence , Thorax , Humans , Thorax/diagnostic imaging , Algorithms , Neural Networks, Computer , Lung/diagnostic imaging
2.
J Vasc Surg Cases Innov Tech ; 9(2): 101093, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37427041

ABSTRACT

An 80-year-old man with a chronic penetrating atherosclerotic ulcer was not a candidate for open surgical repair owing to the presence of diffuse vascular atherosclerosis and a deep ulcerative lesion originating at the level of the aortic arch concavity. No appropriate endovascular landing zone was present in arch zones 1 or 2. However, a totally endovascular branched arch repair involving transapical delivery of the three branches was successful.

3.
Article in English | MEDLINE | ID: mdl-37140560

ABSTRACT

Endoleaks represent a main issue of endovascular approach of thoracic aorta diseases and their treatment continue to be challenging. According to some authors, type II endoleaks sustained by intercostal arteries should not be treated because of the technical difficulties. However, the persistence of a pressurized aneurysmal may confer an ongoing risk of enlargement and/or aortic rupture. We describe the successful treatment of type II endoleak in 2 patients with an intercostal artery's access. In both cases, the endoleak was discovered during follow-up and was treated with its direct coil embolization under local anaesthesia.

4.
J Vasc Surg ; 77(2): 338-346, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36070846

ABSTRACT

BACKGROUND: Complex aortic pathology still represents an open issue in contemporary endovascular management, with continuous technological advancement being introduced in practice over time aiming to improve outcomes. Thus far, the dualism between the fenestrated and branched configuration for visceral artery revascularization is yet unsolved, with each approach having its own pros and cons. The inner branched technology for endovascular aneurysm repair (iBEVAR) aims to take the best out of both strategies, offering wide applicability and stable bridging stent sealing. The objective of this study was to evaluate the early outcomes obtained with a single manufacturer custom-made inner-branched endograft in a multicenter Italian experience. METHODS: All patients consecutively treated with E-xtra design devices in three Italian facilities were enrolled. Anatomic characteristics and perioperative data were analyzed. The main objective was to asses technical and clinical success after iBEVAR. Secondary end points were overall survival, aortic-related mortality, target visceral vessel (TVV) patency, and freedom from target vessel instability during follow-up. RESULTS: From 2016 to 2021, 45 patients were treated with an E-xtra design device revascularizing at least one visceral vessel through an inner branch. The mean age at the time of the procedure was 71.1 ± 9.3 years and 77.8% were males. The total number of target visceral arteries to be bridged with an inner branch was 159. The extent of aortic repair was thoracoabdominal in 91.1% of the cases. Technical success was achieved in 93.3% of the procedures (42/45) with all failures owing to a type I endoleak at final angiography. Each TVV was successfully connected to the graft's main body as planned without complications. Following their intervention, five patients developed spinal cord ischemia and in three of these cases symptoms persisted after discharge (6.7%). At 30 days clinical success was 93.3% (42/45). No death as well as no TVV thrombosis occurred within 30 days from the primary procedures. The mean follow-up was 22.8 ± 14.2 months. The Kaplan-Meier estimate of overall survival and TVV patency at 36 months were 83.9% and 95.9%, respectively. CONCLUSIONS: Inner branches seem to be a promising technology in the complex aortic repair landscape, with an applicability ranging from type II thoracoabdominal aneurysm to type I endoleak repair after infrarenal endografting. Whether iBEVAR could offer results comparable with those provided by fenestrated/branched endovascular aneurysm repair in terms of target vessel patency and stent stability is yet to be established and further studies are, therefore, needed.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Male , Humans , Female , Blood Vessel Prosthesis/adverse effects , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/complications , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/complications , Endoleak/surgery , Treatment Outcome , Risk Factors , Postoperative Complications , Time Factors , Prosthesis Design , Aortography/methods , Registries
5.
JTCVS Tech ; 6: 13-27, 2021 Apr.
Article in English | MEDLINE | ID: mdl-34318130

ABSTRACT

OBJECTIVE: To illustrate our experience and results in patients with diffuse aneurysmal disease treated with arch replacement using the Siena collared graft, a device designed in 2002 to improve the elephant trunk technique. Results of the first step surgical implant and the subsequent treatment strategies, with extensive use of endovascular techniques, are reported. METHODS: All aortic arch-replacement procedures using the Siena graft between February 2002 and January 2020 were retrospectively analyzed for early and late clinical outcomes. RESULTS: Of 146 patients (54 women, 36.9%) with a median age of 69.1 years (interquartile range 58.4-75.0 years), 55 (37.6%) had acute/chronic dissection with false lumen aneurysmal dilatation, 91 (62.3%) had degenerative aneurysms, 45 (30.8%) were redo operations, and 14 (9.5%) had connective tissue disease. First-stage outcomes: 10.9% 30-day mortality (n = 16); 5.4% stroke (n = 8, 6 disabling, 2 nondisabling; 3 fatal); and 0.6% paraplegia. Outcomes for 113 second-stage procedures (77.3%, n = 97 endovascular [66.4%], n = 16 surgical [10.9%]) were 5.3% and 8.8% 30-day and 180-day mortality; no stroke; 10.6% paraplegia. Median follow-up was 5.7 years (range: 0-18.02 years) median survival was 16.65 years (95% lower confidence limit, 10.06 years) with no significant difference between aneurysm and dissection patients. Freedom from further treatment was 87.0% (95% confidence interval, 79.9%-94.7%) at 5 years and 71.4% (95% confidence interval, 71.4%-84.7%) at 10 years; median time to reintervention was 2.59 years (interquartile range, 0.52-5.20 years) with no difference (P = .22) between dissection and aneurysm groups. CONCLUSIONS: Siena collared graft represents a reliable platform for the treatment of diffuse aneurysmal disease. This device offers the flexibility required in the treatment of extended aortic lesions and guarantees the choice of the most appropriate approach for treatment completion. In this context, the availability of hybrid grafts has not modified the role of this device in arch surgery.

6.
Radiol Med ; 126(8): 1129-1137, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34057667

ABSTRACT

PURPOSE: To identify the risk factors associated with patency loss after bailout stenting with third-generation hybrid heparin-bonded nitinol stent of the femoropopliteal segment. METHODS: Prospective, multicenter, single-arm registry including 156 patients (50 females, mean age 72 ± 11 years) subjected, from February 2017 to December 2018, to provisional stenting with Gore Tigris vascular stent of the distal superficial femoral artery, with or without involvement of the popliteal artery, in 9 different centers. The 194 lesions, with Rutherford score ≥ 3, were stented in case of recoil, dissection or residual stenosis not responding to percutaneous trans-luminal angioplasty (PTA). The follow-up (FU) was performed with clinical evaluation and duplex ultrasound (DUS) at 1, 6 and 12 months. RESULTS: The primary patency rate was 99(95%CI 98-100)% at 1 month, 86(80-92)% at 6 months and 81(74-88)% at-12 months. After patency loss, 13/23 (56.5%) patients were re-treated, yielding a primary assisted patency of 91(86-96)% at 6 months and 88(82-94)% at 12 months and a secondary patency of 94(90-98)% at 6 months and 90(84-95)% at 12 months. Rutherford score ≥ 4 (p = 0.03) and previous severe treatments (p = 0.01) were identified as risk factors for early patency loss during FU. The involvement of the popliteal artery was not an independent risk factor for loss of patency. CONCLUSIONS: The bailout stenting of the femoropopliteal segment with third-generation nitinol stents is a safe and effective option in case of recoil, dissection or residual stenosis not responding to PTA. Critical limb ischemia and history of previous major treatment at the same level are significant prognostic factors for patency loss during FU.


Subject(s)
Arterial Occlusive Diseases/epidemiology , Femoral Artery/surgery , Popliteal Artery/surgery , Postoperative Complications/epidemiology , Stents , Aged , Aged, 80 and over , Female , Humans , Italy , Male , Prognosis , Prospective Studies , Prosthesis Design , Registries , Risk Factors , Vascular Patency
8.
Cardiovasc Intervent Radiol ; 41(8): 1174-1183, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29725810

ABSTRACT

AIMS: To report a series of patients treated with the Jotec custom-made endograft for thoraco-abdominal aneurysms and dissections and identify predictive factors for re-intervention. METHODS: We retrospectively analysed 49 patients unsuitable for surgery, treated between 2011 and 2017 (71.3 ± 9.5 years; 15 females). Indications included Crawford type 4 aneurysm in 25 patients, type 3 in 13, type 2 in 4, type 1 in 2 and chronic aneurysmal dilatation of the false lumen following dissection in 5 cases. Mean aneurysm diameter was 58.7 ± 8.4 mm. The study aims were to assess procedural success, complications rate, mortality and long-term follow-up. We also analysed factors that predicted the need for re-intervention. RESULTS: The endograft was successfully deployed in all patients, catheterization of the fenestration and/or branches was achieved in 152/156 (97.4%) vessels. Early complications occurred in 10 patients (3 paraplegia, 3 haemorrhages, pancreatitis, aortic rupture, iliac artery rupture, 2 strokes). Thirty-day mortality was 10.2% and 180-day mortality 14.3%; two non procedure related deaths occurred. Mean follow-up was 23.6 ± 29.9 months [range 1-80]. No patients needed surgical explantation or developed significant renal impairment. Endoleak rate was 34.6% and re-intervention rate 9.7%. The aneurysm sac reduced or was stable in 36/49, and enlarged in 9/49 patients prompting re-intervention. Primary, primary-assisted and secondary patency of fenestrations/branches at 80 months was 90, 96 and 100%. Re-intervention was required more frequently in braches than in fenestrations, most commonly the external type branches. CONCLUSIONS: The results of the Jotec endograft are comparable to other devices, with acceptable complication and re-intervention rates. Fenestration and inner-branch should be preferred due to lower re-intervention rates.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/instrumentation , Endovascular Procedures/methods , Aged , Aortic Dissection/diagnostic imaging , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Blood Vessel Prosthesis , Computed Tomography Angiography/methods , Female , Humans , Male , Retrospective Studies , Time Factors , Treatment Outcome
9.
J Vis Surg ; 4: 82, 2018.
Article in English | MEDLINE | ID: mdl-29780728

ABSTRACT

BACKGROUND: Residual false channel is common after repair of type A acute aortic dissection (TAAAD). Starting from our recent series of TAAAD patients we carried out a retrospective analysis, regarding the failure of primary exclusion at the time of the initial operation. We classified the location of the principal entry tears perfusing the residual false channel. The proposed technique represents our attempt to correct the mechanism of false channel perfusion during primary repair. We describe a new technique designed to address some limitations of standard hemiarch aortic replacement. Its goal are: (I) to reinforce the intimal layer at the arch level; (II) to eliminate inter-luminal communications at the arch level using suture lines around the arch vessels; (III) to provide an elephant trunk configuration for further interventions. METHODS: Between August 2016 and January 2018, 11 patients underwent emergency surgery using this technique; 7 were men; the median age was 74 years. All patients were treated using systemic circulatory arrest under moderate hypothermia (26 °C) and selective cerebral perfusion. All patients had supra-coronary repair; 1 patient had aortic valve replacement + CABG. In the first two patients a manual suture around supra-aortic trunks was used; the subsequent seven patients were treated with a mechanical suture bladeless device. CT scan follow up was performed in all survivors with controls before discharge 3 months and 1 year after operation. RESULTS: No patient died in the operating room and no neurologic deficit was observed in this initial experience. One patient died in POD 5th for low cardiac output syndrome. Median ICU stay was 3 days (IQR, 2-6 days). Hospital mean length of stay was 15.2±8 days. Median cardiopulmonary bypass time was 130 min (IQR, 110-141 min); median arrest time for re-layering was 17 min (IQR, 16-20 min); median total arrest was 36 min (IQR, 29-39 min). Distal aortic anastomosis was performed in zone 0 in 4 patients, zone 1, with innominate replacement, in 5 patients, in zone 2, with branches to innominate and left common carotid arteries, in 2 patients. Median follow up (closing date 06/01/2018) was 443 days (IQR, 262-557 days); no late deaths occurred. No dehiscence at the level of stapler or manual sutures was observed. Proximal 1/3 of the thoracic aorta false channel was obliterated in all cases but one; in 3 cases complete exclusion of the false channel was obtained after operation. In one case stent graft completion was required. CONCLUSIONS: This technique combines the advantages of arch replacement to the simplicity of anterior hemiarch repair. This study demonstrates the safety of the procedure and the possibility to induce aortic remodeling without complex arch replacement.

10.
Cardiovasc Intervent Radiol ; 41(9): 1333-1339, 2018 Sep.
Article in English | MEDLINE | ID: mdl-29671058

ABSTRACT

PURPOSE: To investigate the outcomes of transcatheter arterial embolization (TAE) for the treatment of peptic ulcer bleeding (PUB). MATERIALS AND METHODS: This is a retrospective, multicenter study, which investigated all patients who underwent TAE for the treatment of severe upper gastrointestinal hemorrhage from peptic ulcers in five European centers, between January 1, 2012 and May 1, 2017. All patients had undergone failed endoscopic hemostasis. Forty-four patients (male; mean age 74.0 ± 11.1 years, range 49-94), with bleeding from duodenum (36/44; 81.8%) or gastric ulcer (8/44; 18.2%) were followed up to 3.5 years (range 2-1354 days). In 42/44 cases, bleeding was confirmed by pre-procedural CT angiography. In 50% of the cases, coils were deployed, while in the remaining glue, microparticles, gel foam and combinations of the above were used. The study's outcome measures were 30-day survival technical success (occlusion of feeding vessel and/or no extravasation at completion DSA), overall survival, bleeding relapse and complication rates. RESULTS: The technical success was 100%. The 30-day survival rate was 79.5% (35/44 cases). No patients died due to ongoing or recurrent hemorrhage. Re-bleeding occurred in 2/44 cases (4.5%) and was successfully managed with repeat TAE (one) or surgery (one). The rate of major complications was 4.5% (2/44; one acute pancreatitis and one partial pancreatic ischemia), successfully managed conservatively. According to Kaplan-Meier analysis survival was 71.9% at 3.5 years. CONCLUSIONS: TAE for the treatment of PUB was technically successful in all cases and resulted in high clinical success rate. Minimal re-bleeding rates further highlight the utility of TAE as the second line treatment of choice, after failed endoscopy.


Subject(s)
Embolization, Therapeutic/methods , Peptic Ulcer Hemorrhage/therapy , Peptic Ulcer/therapy , Aged , Aged, 80 and over , Europe , Female , Follow-Up Studies , Humans , Male , Middle Aged , Peptic Ulcer/complications , Peptic Ulcer Hemorrhage/complications , Retrospective Studies , Survival Rate , Treatment Outcome
11.
J Vasc Interv Radiol ; 29(5): 614-622, 2018 05.
Article in English | MEDLINE | ID: mdl-29452721

ABSTRACT

PURPOSE: To prospectively evaluate the safety and efficacy of using the Tigris vascular stent (Gore, Flagstaff, Arizona) alone or in combination with the Viabahn stent (Gore) for revascularizing femoropopliteal Trans-Atlantic Intersociety Consensus (TASC) type B-D lesions with varying degrees of calcification. MATERIALS AND METHODS: Patients with Rutherford stage ≥ 3 and TASC type ≥ B were included in the study. From January 2015 to April 2017, 31 segments in 31 patients (21 men, ovarall mean age 73.3 ± 9.2 years) were treated. The breakdown by TASC type and Rutherford stage were TASC B (n = 12), C (n = 6), and D (n = 13), and Rutherford 3 (n = 28) and 4 (n = 3). The lesions were located in the common femoral artery (n = 1), superficial femoral artery (SFA; n = 20), distal SFA to P1 (n = 3), popliteal P1 (n = 1), popliteal P1-3 (n = 3), popliteal P2-3 (n = 2), and 1 femoropopliteal bypass. There were 18 occlusions (58.1%) and 13 stenoses (41.9%). The mean diseased segment length was 15.5 ± 9.9 cm with 80.6% of moderate/severe calcification. The follow-up consisted of color Doppler ultrasound and clinical assessment at 1, 3, 6, 9, 12, and 15 months. RESULTS: Technical success was 100%. There were no periprocedural or postprocedural complications. The mean stented lesion length was 17.2 ± 10.5 cm with a mean follow-up of 13.1 ± 6.9 months. Primary patency rates at 6, 9, 12, and 15 months were, respectively, 100% (24/31 patients), 90.5% (21/31 patients), 88.9% (20/31 patients), and 80% (15/31 patients). The median postprocedural Rutherford stage was 1. Three occlusions occurred at 7, 9, and 14 months, leading to a target lesion revascularization of 9.7% and a secondary patency of 100% at 15 months. Logistic analysis results demonstrated that lesion length (P = .003) was associated with reocclusion. Amputation-free survival at 15 months was 100%. Intrastent restenosis was observed in four cases (12.9%) but none were associated with worsening of symptoms. No stent fractures were observed. CONCLUSIONS: The Tigris stent used alone or in combination with a Viabahn stent for femoropopliteal TASC B-D lesions demonstrated acceptable 12-month primary patency with a low reintervention rate.


Subject(s)
Femoral Artery , Peripheral Arterial Disease/surgery , Popliteal Artery , Stents , Aged , Female , Humans , Male , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/pathology , Prospective Studies , Treatment Outcome , Ultrasonography, Doppler
12.
J Vasc Surg ; 67(4): 1005-1016, 2018 04.
Article in English | MEDLINE | ID: mdl-29097044

ABSTRACT

OBJECTIVE: The objective of this study was to assess immediate and midterm outcomes for urgent/emergent and elective patients with thoracoabdominal aortic aneurysms (TAAAs) treated with the first commercially available "off-the-shelf" multibranched endograft for endovascular aneurysm repair, with a single-step or a staged surgical approach. METHODS: A multicenter, nonrandomized, retrospective study was conducted of TAAA patients grouped by urgent/emergent and elective treatment with multibranched endograft for endovascular aneurysm repair at 13 Italian centers from November 2012 to August 2016. Urgent/emergent repair was classified as rupture in 16%, impending rupture in 9%, pain in 53%, or a maximum TAAA diameter ≥80 mm in 22%. Study end points were technical success, mortality, spinal cord ischemia, target visceral vessel (TVV) patency, and procedure-related reinterventions at 30 days and at follow-up. RESULTS: Seventy-three patients (274 TVVs) were enrolled. Treatment was performed in elective (n = 41 [56%]) or urgent/emergent (n = 32 [44%]) settings, according to a single-step (n = 30 [41%]) or staged (n = 43 [59%]) approach. Technical success was 92%. Mortality within 30 days was 4% (n = 3 urgent/emergent patients) due to myocardial infarction. Spinal cord ischemia was recorded in two patients (3%; elective group). The primary patency of TVVs was 99% (three renal branch occlusions). Procedure-related reinterventions were required in five cases (7%). At least one adverse event from any cause ≤30 days was registered in 42% (n = 31). At a median follow-up of 18 months (range, 1-43 months), eight (11%) deaths (elective vs urgent/emergent, 2% vs 22%; P = .018), three (1%) cases of branch occlusion or stenosis, and five (7%) reinterventions were recorded. A survival of 88% (standard error [SE], 4%), 86% (SE, 4%), and 82% (SE, 5%) was evidenced at 12, 24, and 36 months, respectively. Urgent/emergent repair and female gender were identified as independent risk factors for all-cause mortality (P < .001 and P = .015, respectively), and the staged approach was identified as protective (P = .026). Freedom from reintervention was 86% (SE, 4%) and 83% (SE, 5%) at 12 and 24 months. CONCLUSIONS: The first off-the-shelf multibranched endograft seems safe in both urgent/emergent and elective settings. The staged surgical approach appears to positively influence overall survival. This unique device and its operators will usher in a new treatment paradigm for TAAA repair.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Aged , Aged, 80 and over , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Aortic Aneurysm, Thoracic/physiopathology , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Computed Tomography Angiography , Elective Surgical Procedures , Emergencies , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Humans , Italy , Kaplan-Meier Estimate , Male , Middle Aged , Postoperative Complications/etiology , Prosthesis Design , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome , Vascular Patency
13.
J Vasc Interv Radiol ; 28(7): 978-986, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28495451

ABSTRACT

PURPOSE: To compare image quality and diagnostic performance of cone-beam computed tomography (CT) and multidetector CT in the detection of hypervascular hepatocellular carcinoma (HCC) in patients with cirrhosis undergoing transarterial chemoembolization with drug-eluting embolic agents. MATERIALS AND METHODS: Fifty-five consecutive patients referred for chemoembolization of hypervascular HCC were prospectively enrolled. Imaging included preprocedural multidetector CT within 1 month before planned treatment, intraprocedural cone-beam CT, and 1-month follow-up multidetector CT. Analysis of image quality was performed with calculations of lesion-to-liver contrast-to-noise ratio (LLCNR) and lesion-to-liver signal-to-noise-ratio (LLSNR). One-month follow-up multidetector CT was considered the reference standard for the detection of HCC nodules. RESULTS: Median LLCNR values were 3.94 (95% confidence interval [CI], 3.06-5.05) for preprocedural multidetector CT and 6.90 (95% CI, 5.17-7.77) for intraprocedural cone-beam CT (P < .0001). Median LLSNR values were 11.53 (95% CI, 9.51-12.44) for preprocedural multidetector CT and 9.36 (95% CI, 8.12-10.39) for intraprocedural cone-beam CT (P < .0104). Preprocedural multidetector CT detected 115 hypervascular nodules with typical HCC behavior, and cone-beam CT detected 15 additional hypervascular nodules that were also visible on 1-month follow-up multidetector CT. CONCLUSIONS: Cone-beam CT has a significantly higher diagnostic performance compared with preprocedural multidetector CT in the detection of HCCs and can influence management of patients with cirrhosis by identifying particularly aggressive tumors.


Subject(s)
Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/therapy , Chemoembolization, Therapeutic/methods , Cone-Beam Computed Tomography/methods , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/therapy , Multidetector Computed Tomography/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Prospective Studies , Signal-To-Noise Ratio
14.
Radiology ; 283(1): 308-309, 2017 04.
Article in English | MEDLINE | ID: mdl-28318442

Subject(s)
Jaundice , Humans
15.
Ann Vasc Surg ; 41: 282.e11-282.e13, 2017 May.
Article in English | MEDLINE | ID: mdl-28192160

ABSTRACT

True and false aneurysms of veins are very rare conditions and only few cases have been described in the literature. We present a case of a 56-year-old female with personal history of primary arterial hypertension and connective tissue disease. Ultrasound of the neck showed a saccular, compressible, hypoechoic structure that appeared to have a direct communication with the left external jugular vein lumen. The venous aneurysm was removed and the histopathology of the mass showed a grossly dilated vein, with continuous aspects of the entire 3 layer of the venous wall, classifying it as a venous aneurysm.


Subject(s)
Aneurysm/diagnostic imaging , Aneurysm/surgery , Jugular Veins/surgery , Ultrasonography, Doppler, Color , Dilatation, Pathologic , Female , Humans , Jugular Veins/diagnostic imaging , Jugular Veins/pathology , Middle Aged , Treatment Outcome
17.
Cardiovasc Intervent Radiol ; 35(5): 1195-200, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22484703

ABSTRACT

PURPOSE: Abdominal aortic aneurysm (AAA) accompanied by common iliac artery (CIA) aneurysms requires a more demanding procedure owing to the difficulties in obtaining an adequate distal landing zone for the stent-graft limb(s), a potential site of endoleak. The "sandwich technique" is a procedure to increase EVAR feasibility in the setting of adverse or challenging CIA anatomy. Its main advantages include no restrictions in terms of CIA diameter or length or internal iliac artery (IIA) diameter, no need to wait for a specific stent-graft. Our purpose is to describe our single-center experience and one year follow-up results of this new procedure. MATERIALS AND METHODS: From April 2009 to June 2010, the sandwich technique was performed in our institution in 7 patients treated for AAA and unilateral CIA aneurysms (n. 5) or bilateral CIA aneurysms (n. 2). Inclusion criteria were the presence of unilateral or bilateral CIA aneurysm (independently from its diameter), IIA artery measuring up to 9 mm in its maximum diameter, not dilatation of IIA and EIA. RESULTS: The mean follow-up length was 15 months (range: 14-20 months). All stent-implanted iliac branches remained patent on 1 year follow-up and IIA flow was preserved. None of the patients had symptoms of pelvic ischemia. CT scan follow-up showed aneurysm shrinkage in five patients, without any sign of endoleaks in all cases. CONCLUSIONS: In selected cases, the "sandwich technique" showed good outcomes confirming to be a safe and easy to perform way to overcome anatomical constraints and expanding the limits of EVAR.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/methods , Iliac Aneurysm/surgery , Stents , Aged , Aged, 80 and over , Angiography , Aortic Aneurysm, Abdominal/diagnostic imaging , Endoleak/prevention & control , Feasibility Studies , Female , Follow-Up Studies , Humans , Iliac Aneurysm/diagnostic imaging , Male , Middle Aged , Treatment Outcome , Vascular Patency
18.
Urologia ; 79(1): 36-43, 2012.
Article in Italian | MEDLINE | ID: mdl-22307531

ABSTRACT

INTRODUCTION: Iatrogenic ureteral lesions are well-known complications of abdominal and pelvic surgery. A combined radiologic-urologic approach might be necessary to repair these lesions. MATERIALS AND METHODS: A 69-year-old woman underwent bilateral hysteroannessectomy for endometrial cancer. She then became anuric. A CT scan showed multiple urinomas caused by bilateral ureteral lesions. The continuity of the two urinary tracts was restored using ureteral stents in a combined urologic and radiologic procedure. RESULTS: The patient improved clinically and the renal function returned within normal limits. CONCLUSIONS: The combined antegrade-retrograde approach is an effective technique to solve iatrogenic ureteral lesions.


Subject(s)
Anuria/etiology , Intraoperative Complications/surgery , Nephrostomy, Percutaneous/methods , Postoperative Complications/surgery , Radiography, Interventional , Stents , Surgery, Computer-Assisted , Ureter/injuries , Urinoma/surgery , Urologic Surgical Procedures/methods , Aged , Endometrial Neoplasms/surgery , Female , Humans , Hydronephrosis/etiology , Hydronephrosis/surgery , Hysterectomy , Iatrogenic Disease , Lymph Node Excision , Postoperative Complications/etiology , Salpingectomy , Tomography, X-Ray Computed , Ureter/surgery , Urinoma/etiology
19.
Cardiovasc Intervent Radiol ; 35(1): 176-9, 2012 Feb.
Article in English | MEDLINE | ID: mdl-21901580

ABSTRACT

An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided in two parts by an intimal flap. The proximal landing zone was suitable to place a thoracic stent graft. The distal landing zone was created by cutting the intimal flap in the distal third of the descending thoracic aorta with a radiofrequency guide wire and intravascular ultrasound catheter.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Catheter Ablation/instrumentation , Stents , Aortic Dissection/diagnostic imaging , Angiography , Aortic Aneurysm, Thoracic/diagnostic imaging , Fluoroscopy , Humans , Middle Aged , Radio Waves , Tomography, X-Ray Computed
20.
Ann Thorac Surg ; 90(6): e88-90, 2010 Dec.
Article in English | MEDLINE | ID: mdl-21095293

ABSTRACT

We report the successful treatment of a life-threatening thoracoabdominal aneurysm in a young patient affected by type I Loeys-Dietz syndrome. To overcome anatomic and surgical difficulties, we used an original strategy and a specially designed surgical tool. The clinical and technical aspects of this approach are presented.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Loeys-Dietz Syndrome/complications , Adult , Aortic Aneurysm, Thoracic/complications , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortography , Follow-Up Studies , Humans , Male , Prosthesis Design , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...