1.
PLoS One ; 15(12): e0244963, 2020.
Article in English | MEDLINE | ID: mdl-33378363

ABSTRACT

The COVID-19 pandemic disrupted the world in 2020 by spreading at unprecedented rates and causing tens of thousands of fatalities within a few months. The number of deaths dramatically increased in regions where the number of patients in need of hospital care exceeded the availability of care. Many COVID-19 patients experience Acute Respiratory Distress Syndrome (ARDS), a condition that can be treated with mechanical ventilation. In response to the need for mechanical ventilators, designed and tested an emergency ventilator (EV) that can control a patient's peak inspiratory pressure (PIP) and breathing rate, while keeping a positive end expiratory pressure (PEEP). This article describes the rapid design, prototyping, and testing of the EV. The development process was enabled by rapid design iterations using additive manufacturing (AM). In the initial design phase, iterations between design, AM, and testing enabled a working prototype within one week. The designs of the 16 different components of the ventilator were locked by additively manufacturing and testing a total of 283 parts having parametrically varied dimensions. In the second stage, AM was used to produce 75 functional prototypes to support engineering evaluation and animal testing. The devices were tested over more than two million cycles. We also developed an electronic monitoring system and with automatic alarm to provide for safe operation, along with training materials and user guides. The final designs are available online under a free license. The designs have been transferred to more than 70 organizations in 15 countries. This project demonstrates the potential for ultra-fast product design, engineering, and testing of medical devices needed for COVID-19 emergency response.


Subject(s)
COVID-19/therapy , Equipment Design/methods , Respiration, Artificial/instrumentation , Ventilators, Mechanical/adverse effects , Animals , COVID-19/pathology , Humans , Respiration, Artificial/methods , Respiratory Mechanics/physiology , Respiratory Rate/physiology , SARS-CoV-2 , Swine
2.
IEEE Trans Biomed Circuits Syst ; 14(5): 1088-1096, 2020 10.
Article in English | MEDLINE | ID: mdl-32870799

ABSTRACT

In response to anticipated shortages of ventilators caused by the COVID-19 pandemic, many organizations have designed low-cost emergency ventilators. Many of these devices are pressure-cycled pneumatic ventilators, which are easy to produce but often do not include the sensing or alarm features found on commercial ventilators. This work reports a low-cost, easy-to-produce electronic sensor and alarm system for pressure-cycled ventilators that estimates clinically useful metrics such as pressure and respiratory rate and sounds an alarm when the ventilator malfunctions. A low-complexity signal processing algorithm uses a pair of nonlinear recursive envelope trackers to monitor the signal from an electronic pressure sensor connected to the patient airway. The algorithm, inspired by those used in hearing aids, requires little memory and performs only a few calculations on each sample so that it can run on nearly any microcontroller.


Subject(s)
Clinical Alarms , Coronavirus Infections/therapy , Monitoring, Physiologic/instrumentation , Pneumonia, Viral/therapy , Respiration, Artificial/instrumentation , Signal Processing, Computer-Assisted , Ventilators, Mechanical , Algorithms , COVID-19 , Electronics , Equipment Design , Humans , Pandemics , Respiration , Software
3.
Ultrasound Med Biol ; 32(11): 1763-70, 2006 Nov.
Article in English | MEDLINE | ID: mdl-17112962

ABSTRACT

Thermal injury, a potential mechanism of ultrasound-induced lung hemorrhage, was studied by comparing lesions induced by an infrared laser (a tissue-heating source) with those induced by pulsed ultrasound. A 600-mW continuous-wave CO2 laser (wavelength approximately 10.6 microm) was focused (680-microm beamwidth) on the surface of the lungs of rats for a duration between 10 to 40 s; ultrasound beamwidths were between 310 and 930 microm. After exposure, lungs were examined grossly and then processed for microscopic evaluation. Grossly, lesions induced by laser were somewhat similar to those induced by ultrasound; however, microscopically, they were dissimilar. Grossly, lesions were oval, red to dark red and extended into subjacent tissue to form a cone. The surface was elevated, but the center of the laser-induced lesions was often depressed. Microscopically, the laser-induced injury consisted of coagulation of tissue, cells and fluids, whereas injury induced by ultrasound consisted solely of alveolar hemorrhage. These results suggest that ultrasound-induced lung injury is most likely not caused by a thermal mechanism.


Subject(s)
Hemorrhage/etiology , Lung Diseases/etiology , Ultrasonic Therapy/adverse effects , Animals , Hemorrhage/pathology , Hot Temperature/adverse effects , Lasers/adverse effects , Lung Diseases/pathology , Necrosis/etiology , Pleura/pathology , Rats , Rats, Sprague-Dawley