Appl Radiat Isot ; 89: 176-85, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24657473

ABSTRACT

(127)Xe has a longer half-life than (131m)Xe, it can be easily purely produced and it is present in the environment at very low level. For these reasons, (127)Xe is supposed to be a convenient quality control radionuclide for remote noble gas stations of the International Monitoring System (IMS) network. As CEA/DAM has recently developed two new photon/electron setups for low-level detection of (131m)Xe, (133m)Xe, (133)Xe and (135)Xe, we took the opportunity to test these setups for the measurement of a (127)Xe standard. The results and a detailed description of these measurements are presented in this paper. They illustrate the complexity of (127)Xe decay, emitting simultaneously several γ, X-rays, conversion electrons and Auger electrons; this results in highly summated coincidence spectra. The measurements performed provide precise electron energy calibration of the setups. The count rate of electrons in coincidence with iodine Kα X-rays was found to be surprisingly low, leading to the study of electron-gated photon spectrum. Finally, a comparison of three photon/electron coincidence spectra obtained with three different setups is given. The use of (127)Xe as a standard for energy calibration of IMS noble gas station is possible, but it appears to be quite complicated for efficiency check of noble gas station equipped with ß/γ detectors.

2.
Appl Radiat Isot ; 87: 48-52, 2014 May.
Article in English | MEDLINE | ID: mdl-24332879

ABSTRACT

The ability to quantify isotopic ratios of 135, 133 m, 133 and 131 m radioxenon is essential for the verification of the Comprehensive Nuclear-Test Ban Treaty (CTBT). In order to improve detection limits, CEA has developed a new on-site setup using photon/electron coincidence (Le Petit et al., 2013. J. Radioanal. Nucl. Chem., DOI : 10.1007/s 10697-013-2525-8.). Alternatively, the electron detection cell equipped with large silicon chips (PIPS) can be used with HPGe detector for laboratory analysis purpose. This setup allows the measurement of ß/γ coincidences for the detection of (133)Xe and (135)Xe; and K-shell Conversion Electrons (K-CE)/X-ray coincidences for the detection of (131m)Xe, (133m)Xe and (133)Xe as well. Good energy resolution of 11 keV at 130 keV and low energy threshold of 29 keV for the electron detection were obtained. This provides direct discrimination between K-CE from (133)Xe, (133m)Xe and (131m)Xe. Estimation of Minimum Detectable Activity (MDA) for (131m)Xe is in the order of 1mBq over a 4 day measurement. An analysis of an environmental radioxenon sample using this method is shown.

SELECTION OF CITATIONS
SEARCH DETAIL
...