Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Diagnostics (Basel) ; 12(8)2022 Aug 04.
Article in English | MEDLINE | ID: mdl-36010241

ABSTRACT

The objective of this study was to investigate subtraction images from different polychromatic and virtual monochromatic reconstructions of dual-energy computed tomography (CT) for the detection of inflammation (synovitis/tenosynovitis or peritendonitis) in patients with hand arthritis. In this IRB-approved prospective study, 35 patients with acute hand arthritis underwent contrast-enhanced dual-energy CT and musculoskeletal ultrasound (MSUS) of the clinically dominant hand. CT subtractions (CT-S) were calculated from 80 and 135 kVp source data and monochromatic 50 and 70 keV images. CT-S and MSUS were scored for synovitis and tenosynovitis/peritendonitis. Specificity, sensitivity and diagnostic accuracy were assessed by using MSUS as a reference. Parameters of objective image quality were measured. Thirty-three patients were analyzed. MSUS was positive for synovitis and/or tenosynovitis/peritendonitis in 28 patients. The 70 keV images had the highest diagnostic accuracy, with 88% (vs. 50 keV, 82%; 80 kVp, 85%; and 135 kVp, 82%), and superior sensitivity, with 96% (vs. 50 keV: 86%, 80 kVp: 93% and 135 kVp: 79%). The 80 kVp images showed the highest signal- and contrast-to-noise ratio, while the 50 keV images provided the lowest image quality. While all subtraction methods of contrast-enhanced dual-energy CT proved to be able to detect inflammation with sufficient diagnostic accuracy, virtual monochromatic images with low keV showed no significant improvement over conventional subtraction techniques and lead to a loss of image quality.

2.
Eur Radiol ; 32(9): 6376-6383, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35359165

ABSTRACT

OBJECTIVES: To investigate the performance of dual-energy CT (DECT)-generated iodine maps (iMap) and CT subtraction (CT-S) in the detection of synovitis, tenosynovitis, and peritendonitis/paratenonitis compared to magnetic resonance imaging (MRI) using musculoskeletal ultrasound (MSUS) as standard of reference. METHODS: This IRB-approved prospective study consecutively investigated patients with undifferentiated arthritis. All patients underwent MSUS, MRI and contrast-enhanced DECT of the hand; from the latter conventional CT-S, image-based iMap (iMap-I) and raw data-based iMap (iMap-RD) were reconstructed. CT and MRI datasets were scored for synovitis and tenosynovitis/paratenonitis applying the modified Rheumatoid Arthritis MRI Score (RAMRIS). Sensitivity, specificity, and diagnostic accuracy were calculated. Non-inferiority was tested using the one-tailed McNemar test. Correlation of sum scores was assessed using Pearson's test. Interreader reliability was assessed using Cohen's kappa. RESULTS: Overall, 33 patients were included. MSUS was positive for synovitis and tenosynovitis/paratenonitis in 28 patients with a sum score of 6.91. Excellent correlation with MSUS was shown for CT-S (sum score 6.38; r = 0.91), iMap-RD (sum score 9.74; r = 0.82), MRI (sum score 12.70; r = 0.85), and iMap-I (sum score 6.94; r = 0.50). CT-S had the highest diagnostic accuracy of 83%, followed by iMap-I (78%), MRI (75%), and iMap-RD (74%). All modalities showed non-inferiority. Reader agreement was good for CT-S and MRI (κ = 0.62; 0.64) and fair for iMap-RD and iMap-I (κ = 0.31; 0.37). CONCLUSION: CT-S and iMap allow highly standardized arthritis imaging and are suitable for clinical practice. MSUS still has the highest availability for arthritis imaging and served as gold standard for this study. KEY POINTS: • CT subtraction, iodine map with dual-energy CT, and MRI showed non-inferiority to musculoskeletal ultrasound. • MRI was the most sensitive but least specific imaging technique compared with CT subtraction and dual-energy CT. • CT subtraction showed the best correlation with musculoskeletal ultrasound.


Subject(s)
Arthritis, Rheumatoid , Iodine , Synovitis , Tenosynovitis , Humans , Magnetic Resonance Imaging/methods , Prospective Studies , Reproducibility of Results , Synovitis/diagnostic imaging , Synovitis/pathology , Tomography, X-Ray Computed/methods
3.
RMD Open ; 8(1)2022 02.
Article in English | MEDLINE | ID: mdl-35177555

ABSTRACT

OBJECTIVE: To compare the diagnostic accuracy of susceptibility-weighted imaging (SWI), standard T1-weighted (T1w) images and high-resolution 3D-gradient echo sequences (volumetric interpolated breath-hold examination (VIBE)) for detection of erosions in patients with peripheral arthritis using CT as standard of reference. MATERIALS AND METHODS: A total of 36 patients were included in the study. All patients underwent CT and MRI, including SWI, VIBE and T1w sequences of the clinically more affected hand. Two trained readers scored all imaging datasets separately for erosions in a blinded fashion. Specificity, sensitivity and diagnostic accuracy of MRI sequences were calculated on a per-patient level. RESULTS: CT was positive for erosion in 16 patients and 77 bones (Rheumatoid Arthritis MRI Score >0), T1w in 28 patients, VIBE in 25 patients and SWI in 17 patients. All MRI sequences performed with comparably high sensitivities (T1w 100%, VIBE 94% and SWI 94%). SWI had the highest specificity of 90%, followed by VIBE (50%) and T1w (40%). Both T1w and VIBE produced significantly higher sum scores than CT (341 and 331 vs 148, p<0.0001), while the sum score for SWI did not differ from CT (119 vs 148; p=0.411). CONCLUSION: Specificity for erosion detection remains a challenge for MRI when conventional and high-resolution sequences are used but can be improved by direct bone depiction with SWI. Both T1w and VIBE tend to overestimate erosions, when CT is used as the standard of reference.


Subject(s)
Arthritis , Magnetic Resonance Imaging , Breath Holding , Hand , Humans , Magnetic Resonance Imaging/methods , Tomography, X-Ray Computed
5.
Skeletal Radiol ; 50(2): 417-423, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32803375

ABSTRACT

OBJECTIVES: To evaluate differences in collagen density as detected by dual-energy computed tomography (DECT) of wrist ligaments between patients with calcium pyrophosphate-dihydrate deposition disease (CPPD) and a control group in order to gain insight into changes of the extracellular matrix in response to crystal deposition. MATERIALS AND METHODS: This retrospective study included 28 patients (18 with CPPD, 10 controls) who underwent DECT of the wrist. Collagen density maps were reconstructed from the DECT datasets and used to measure densities in regions of interest (ROIs) placed in the scapholunate (SL) ligament (dorsal, palmar, proximal), lunotriquetral (LT) ligament, and extensor carpi radialis (ECR) tendon, (n = 260 measurements). The presence of calcifications on standard CT images in these regions was assessed by a blinded reader. Densities were compared with nonparametric tests, and linear regression analysis was performed to investigate the impact of age, sex, and CT- detected calcium deposition on collagen density. RESULTS: Collagen density in the SL ligament was significantly higher in CPPD patients than in controls (overall mean: 265.4 ± 32.1 HU vs. 196.3 ± 33.8 HU; p < 0.001). In the ECR tendon, collagen densities did not differ significantly (p = 0.672): 161.3 ± 20.1 HU in CPPD vs. 163.6 ± 12.0 HU in controls. Regression analysis showed that diagnosis, but not age or calcification, had a significant impact on collagen density. CONCLUSION: Collagen density of the SL ligament is significantly higher in CPPD patients than in control patients. Further research is needed to understand these changes in the extracellular matrix of ligaments in CPPD.


Subject(s)
Chondrocalcinosis , Wrist , Collagen , Humans , Retrospective Studies , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...