Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Intensive Care Med ; 27(2): 119-27, 2012.
Article in English | MEDLINE | ID: mdl-21220269

ABSTRACT

OBJECTIVE: To investigate the effectiveness of the constant-flow, pressure-volume curve (PVC) to prescribe positive end-expiratory pressure (PEEP) in acute lung injury (ALI) and risk of cardiopulmonary deterioration during the PVC process. DESIGN: A retrospective, cohort study. SETTING: A surgical intensive care unit (ICU) of a tertiary, university hospital. PATIENTS: Fifty consecutive ventilated patients diagnosed with ALI undergoing the PVC maneuver from 1999 to 2003. INTERVENTIONS: Titration of PEEP based on the lower inflection point of the constant-flow, pressure-volume curve. MEASUREMENTS AND MAIN RESULTS: Patients were divided into 2 groups based on PVC-guided PEEP changes of <3 cm H2O (PVC-NC or "no change") or ≥3 cm H2O (PVC-CHG or "change") from the initial empiric prescription. There was a greater increase in partial pressure of arterial oxygen (PaO2)/fractional concentration of inspired oxygen (FiO2) in the PVC-CHG group, with a mean change of 80 ± 50 (95% confidence interval [CI] 61, 98) versus 42 ± 54 (95% CI 17, 67) in the PVC-NC group. Eighty-two percent of patients (41/50) showed an increase in ratio of partial pressure of arterial oxygen to fraction of inspired oxygen (PaO2/FiO2) by 20% within 6 to 24 hours after the PVC test-greater in the PVC-CHG group (OR 1.44, 95% CI 1.02, 2.01). Thirteen percent (4/30) within the PVC-CHG group and none within the PVC-NC group (0/20) required a 25% increase in vasoactive infusion rates (P = .089) in relation to the procedure. Univariate logistic regression showed that PVC-CHG was significantly associated with a 20% change in PaO2/FiO2 (OR 7.54, 95% CI 1.37, 41.41). Multivariate logistic modeling showed that PVC-guided PEEP changes of ≥3 cm H2O, age ≤65 years, and pre-PVC FiO2 ≥ .85 were significantly associated with a 20% increase in PaO2/FiO2 (receiver operator area under the curve = .86). CONCLUSIONS: In the setting of acute lung injury, use of the constant-flow, pressure-volume curve to prescribe PEEP appears associated with improvement in oxygenation with limited risk of acute, process-related, cardiopulmonary deterioration.


Subject(s)
Acute Lung Injury/complications , Hypertension, Pulmonary/etiology , Hypertension, Pulmonary/prevention & control , Hypoxia/therapy , Intermittent Positive-Pressure Ventilation/methods , Acute Lung Injury/therapy , Blood Volume Determination , Cohort Studies , Confidence Intervals , Female , Humans , Hypoxia/etiology , Intensive Care Units , Male , Middle Aged , Positive-Pressure Respiration
SELECTION OF CITATIONS
SEARCH DETAIL
...