Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Knee Surg Sports Traumatol Arthrosc ; 25(6): 1712-1719, 2017 Jun.
Article in English | MEDLINE | ID: mdl-26499998

ABSTRACT

PURPOSE: The purpose of our study was to compare the accuracy of the rotational position of the femoral component in total knee arthroplasty aligned with patient individualized jigs (PSJ) to a gap balancing technique (GBT). METHODS: A consecutive series of 21 osteoarthritic patients were treated with 22 cruciate-retaining total knee prostheses. During surgery, the rotation of the femoral component pinholes was recorded for all knees using PSJ and GBT and transferred to computer tomograms (CT). The rotational differences between PSJ and GBT relative to the transepicondylar axis were analysed. RESULTS: The medium rotation of the femoral component pinholes was 1.3° ± 5.1° (min = -6.3°; max = 14.4°) for PSJ and 0.1 ± 1.4° (min = -1.6°; max = 3.4°) for GBT. Outliers of more than 3° were found more frequently with PSJ in 12 cases but only in one for GBT. CONCLUSION: Based on our study, we would not recommend relying intra-operatively solely on the CT-based PSJ without the option to adjust or control femoral rotation. LEVEL OF EVIDENCE: II.


Subject(s)
Arthroplasty, Replacement, Knee , Femur/surgery , Aged , Anatomic Landmarks/surgery , Arthroplasty, Replacement, Knee/methods , Female , Femur/diagnostic imaging , Femur/physiopathology , Humans , Knee Prosthesis , Male , Range of Motion, Articular , Rotation , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...