Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Healthcare (Basel) ; 12(13)2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38998805

ABSTRACT

Traumatic peripheral nerve injuries (PNI), present with symptoms ranging from pain to loss of motor and sensory function. Difficulties in intraoperative visual assessment of nerve functional status necessitate intraoperative nerve conduction studies (INCSs) by neurosurgeons and neurologists to determine the presence of functioning axons in the zone of a PNI. This process, also referred to as nerve "inching", uses a set of stimulating and recording electrode hooks to lift the injured nerve from the surrounding surgical field and to determine whether an electrical stimulus can travel through the zone of injury. However, confounding electrical signal artifacts can arise from the current workflow and electrode design, particularly from the mandatory lifting of the nerve, complicating the definitive assessment of nerve function and neurosurgical treatment decision-making. The objective of this study is to describe the design process and verification testing of our group's newly designed stimulating and recording electrodes that do not require the lifting or displacement of the injured nerve during INCSs. Ergonomic in vivo analysis of the device within a porcine model demonstrated successful intraoperative manipulation of the device, while quantitative nerve action potential (NAP) signal analysis with an ex vivo simulated "inching" procedure on healthy non-human primate nerve tissue demonstrated excellent reproducible recorded NAP fidelity and the absence of NAP signal artifacts at all points of recording. Lastly, electrode pullout force testing determined maximum forces of 0.43 N, 1.57 N, and 3.61 N required to remove the device from 2 mm, 5 mm, and 1 cm nerve models, respectively, which are well within established thresholds for nerve safety. These results suggest that these new electrodes can safely and successfully perform accurate PNI assessment without the presence of artifacts, with the potential to improve the INCS standard of care while remaining compatible with currently used neurosurgical technology, infrastructure, and clinical workflows.

2.
J Vitreoretin Dis ; 7(3): 203-210, 2023.
Article in English | MEDLINE | ID: mdl-37188214

ABSTRACT

Purpose: To compare retrobulbar anesthesia injection (RAI) with hyaluronidase and without hyaluronidase in vitreoretinal surgery using clinical efficacy measures and orbital manometry (OM). Methods: This prospective randomized double-masked study enrolled patients who had surgery using an 8 mL RAI with or without hyaluronidase. Outcome measures were clinical block effectiveness (akinesia, pain scores, need for supplemental anesthetic or sedative medications) and orbital dynamics assessed by OM before and up to 5 minutes after RAI. Results: Twenty-two patients received RAI with hyaluronidase (Group H+), and 25 received RAI without hyaluronidase (Group H-). Baseline characteristics were well matched. No differences in clinical efficacy were found. OM showed no difference in preinjection orbital tension (4 ± 2 mm Hg in both groups) or calculated orbital compliance (0.6 ± 0.3 mL/mm Hg, Group H+; 0.5 ± 0.2 mL/mm Hg, Group H-) (P = .13). After RAI, the peak orbital tension was 23 ± 15 mm Hg in Group H+ and 24 ± 9 mm Hg in Group H- (P = .67); it declined more rapidly in Group H+. Orbital tension at 5 minutes was 6 ± 3 mm Hg in Group H+ and 11 ± 5 mm Hg in Group H- (P = .0008). Conclusions: OM showed faster resolution of post-RAI orbital tension elevation with hyaluronidase; however, there were no clinically evident differences between groups. Thus, 8 mL RAI with or without hyaluronidase is safe and can achieve excellent clinical results. Our data do not support the routine use of hyaluronidase with RAI.

SELECTION OF CITATIONS
SEARCH DETAIL
...