Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Publication year range
1.
Medicina (B Aires) ; 77(5): 353-357, 2017.
Article in Spanish | MEDLINE | ID: mdl-29044009

ABSTRACT

Candid#1 is the first live attenuated vaccine produced and registered in Argentina. Produced since 2003 at the INEVH to prevent Argentine hemorrhagic fever, it is obtained by harvesting supernatants of diploid cells infected with an attenuated strain of Junin virus and subsequent lyophilization. The stability of this vaccine is crucial to ensure its effectiveness. This study was aimed to evaluate the stability of Candid#1 by exposing it to different time and temperature conditions. Three vaccine batches produced in 2003 were analysed according to the following storage scheme: (a) reconstituted vaccine at 2 °C to 8 °C for 8 days; (b) lyophilized vaccine at 2 °C to 8 °C for 6 months; (c) lyophilized vaccine at -18 °C to -20 °C for 10 years. The potency was assessed in Vero cell monolayers under agar. The results were: (a) reconstituted vaccine was stable between 2 °C and 8 °C for 8 days, (b) lyophilized vaccine was stable between 2 °C and 8 °C for 2 months, and (c) lyophilized vaccine was stable 9 years between -18 °C and -20 °C, keeping all its properties. These results allowed us to establish the following storage conditions and expiration times for Candid#1: (a) reconstituted: 12 hours between 2 °C and 8 °C, (b) lyophilized: 30 days between 2 °C and 8 °C and (c) lyophilized: 9 years between -18 °C and -20 °C. Based on our results, favorable changes were made in the conditions of transport, storage and distribution of the vaccine. Domestic freezers in strategically located centers were installed, allowing the preservation of vaccine stocks for distribution to secondary vaccination centers.


Subject(s)
Antibodies, Viral/immunology , Arenaviruses, New World/immunology , Drug Storage/methods , Hemorrhagic Fever, American/prevention & control , Viral Vaccines/immunology , Argentina , Drug Stability , Humans , Vaccines, Attenuated/immunology
2.
Medicina (B.Aires) ; 77(5): 353-357, oct. 2017. tab
Article in Spanish | LILACS | ID: biblio-894499

ABSTRACT

Candid#1 es la primera vacuna a virus vivo atenuado producida y registrada en Argentina. Se produce en el INEVH desde 2003 para prevenir la fiebre hemorrágica argentina y se obtiene mediante cosecha de sobrenadantes de cultivos de células diploides infectadas con una cepa atenuada del virus Junín, formulación y posterior liofilización. Su estabilidad es crucial para asegurar su efectividad. El objetivo de este trabajo fue evaluar la estabilidad de Candid#1 exponiéndola a distintas condiciones de temperatura y tiempo. Tres lotes producidos en 2003 fueron sometidos al siguiente esquema de almacenamiento: (a) vacuna reconstituida conservada entre 2 °C y 8 °C durante 8 días, (b) vacuna liofilizada conservada entre 2 °C y 8 °C durante 6 meses, y (c) vacuna liofilizada conservada entre -18 °C y -20 °C durante 10 años. La potencia fue evaluada en monocapa de células Vero bajo agar. Los resultados fueron: (a) Candid#1 reconstituida fue estable 8 días entre 2 °C y 8 °C, (b) Candid#1 liofilizada fue estable 2 meses entre 2 °C y 8 °C y (c) Candid#1 liofilizada fue estable 9 años entre -18 °C y -20 °C manteniendo todos sus atributos. Estos resultados permitieron establecer las siguientes condiciones de almacenamiento: reconstituida 12 horas entre 2 °C y 8 °C, liofilizada 30 días entre 2 °C y 8 °C y 9 años entre -18 °C y -20 °C. A la luz de estos resultados, se generaron cambios favorables en las condiciones de transporte, almacenamiento y distribución de la vacuna. Se implementó la instalación de freezers domésticos en centros estratégicamente distribuidos, permitiendo preservar stocks de vacuna y distribuir las dosis necesarias a vacunatorios.


Candid#1 is the first live attenuated vaccine produced and registered in Argentina. Produced since 2003 at the INEVH to prevent Argentine hemorrhagic fever, it is obtained by harvesting supernatants of diploid cells infected with an attenuated strain of Junin virus and subsequent lyophilization. The stability of this vaccine is crucial to ensure its effectiveness. This study was aimed to evaluate the stability of Candid#1 by exposing it to different time and temperature conditions. Three vaccine batches produced in 2003 were analysed according to the following storage scheme: (a) reconstituted vaccine at 2 °C to 8°C for 8 days; (b) lyophilized vaccine at 2 °C to 8 °C for 6 months; (c) lyophilized vaccine at -18 °C to -20 °C for 10 years. The potency was assessed in Vero cell monolayers under agar. The results were: (a) reconstituted vaccine was stable between 2 °C and 8 °C for 8 days, (b) lyophilized vaccine was stable between 2 °C and 8 °C for 2 months, and (c) lyophilized vaccine was stable 9 years between -18 °C and -20 °C, keeping all its properties. These results allowed us to establish the following storage conditions and expiration times for Candid#1: (a) reconstituted: 12 hours between 2 °C and 8 °C, (b) lyophilized: 30 days between 2 °C and 8 °C and (c) lyophilized: 9 years between -18 °C and -20 °C. Based on our results, favorable changes were made in the conditions of transport, storage and distribution of the vaccine. Domestic freezers in strategically located centers were installed, allowing the preservation of vaccine stocks for distribution to secondary vaccination centers.


Subject(s)
Humans , Viral Vaccines/immunology , Arenaviruses, New World/immunology , Drug Storage/methods , Hemorrhagic Fever, American/prevention & control , Antibodies, Viral/immunology , Argentina , Vaccines, Attenuated/immunology , Drug Stability
3.
Viral Immunol ; 19(2): 196-201, 2006.
Article in English | MEDLINE | ID: mdl-16817762

ABSTRACT

Neutralizing antibody (NT Ab) titers to Candid #1 (C#1) vaccine against Argentine hemorrhagic fever were studied for 2 years post-vaccination in 330 volunteers, to assess whether the kinetics and/or magnitude of this immune response is modified by previous infection with the arena viruses Junin (JUN) and lymphocytic choriomeningitis (LCM). A total of 160 volunteers received C#1, distributed as follows: without detectable pre-infection with arenaviruses (n = 54); with pre-existing antibodies to JUN (n = 55); with pre-existing antibodies to LCM (n = 51). The remaining 170 individuals received placebo. Levels of anti-JUN NT Ab displayed a trend in which titers increased with the virulence of the infecting strain, from C#1 (X = 49), through subclinical JUN infection (X = 229), vaccination following subclinical infection (X = 367) to JUN clinical infection (X =773). It was also found that the mean titer of NT Ab to C#1 did not vary significantly during 2 years of study and was: a) significantly lower than that elicited by wild strains of JUN, both clinical and subclinical infections (p < 0.01); b) significantly increased the titers of pre-existing anti-JUN Ab (p < 0.01); and c) was not modified by pre-existing anti-LCM Ab (p > 0.05). These data indicate that the immune response to C#1 boosts pre-existing immunity to JUN virus and is not changed by previous experience with LCM virus.


Subject(s)
Antibodies, Viral/blood , Arenaviridae Infections/immunology , Arenaviruses, New World/immunology , Hemorrhagic Fever, American/prevention & control , Lymphocytic Choriomeningitis/immunology , Viral Vaccines/administration & dosage , Viral Vaccines/immunology , Adolescent , Adult , Aged , Arenaviridae Infections/virology , Hemorrhagic Fever, American/immunology , Hemorrhagic Fever, American/virology , Humans , Junin virus/immunology , Lymphocytic Choriomeningitis/virology , Lymphocytic choriomeningitis virus/immunology , Male , Middle Aged , Neutralization Tests , Treatment Outcome , Vaccination
4.
Medicina (B Aires) ; 65(4): 329-32, 2005.
Article in Spanish | MEDLINE | ID: mdl-16193711

ABSTRACT

Candid #1 vaccine against Argentine Hemorrhagic Fever produced in USA versus lots of the same vaccine made in Argentina were compared in guinea pigs regarding safety, immunogenicity and protective efficacy against a challenge with pathogenic Junin virus. Lots No Exp 3, 7A and 8A of Argentine origin as well as lot TSI 5-1-92 from USA were inoculated in guinea pigs of 250-400 g in two consecutive assays. Ten animals inoculated with saline performed as normal controls in each experiment. Parameters studied were: a) temperature; b) body weight; c) neutralizing antibodies to Junin virus; d) response to viral challenge. Animals gained weight and remained normothermic up to the challenge. Guinea pigs that received Candid #1 from any manufacturer elicited neutralizing antibodies to Junin virus (titles from 40 to 81920) and survived to challenge whilst 8/10 animals died in each control group. Data presented demonstrated that Candid #1 vaccines from USA or Argentine manufacturers were equally safe, immunogenic and protective in guinea pigs.


Subject(s)
Hemorrhagic Fever, American/prevention & control , Junin virus/immunology , Viral Vaccines/immunology , Animals , Argentina , Disease Models, Animal , Drug Evaluation, Preclinical , Guinea Pigs , Hemorrhagic Fever, American/immunology , Vaccines, Attenuated/immunology
5.
Medicina [B Aires] ; 65(4): 329-32, 2005.
Article in Spanish | BINACIS | ID: bin-38261

ABSTRACT

Candid #1 vaccine against Argentine Hemorrhagic Fever produced in USA versus lots of the same vaccine made in Argentina were compared in guinea pigs regarding safety, immunogenicity and protective efficacy against a challenge with pathogenic Junin virus. Lots No Exp 3, 7A and 8A of Argentine origin as well as lot TSI 5-1-92 from USA were inoculated in guinea pigs of 250-400 g in two consecutive assays. Ten animals inoculated with saline performed as normal controls in each experiment. Parameters studied were: a) temperature; b) body weight; c) neutralizing antibodies to Junin virus; d) response to viral challenge. Animals gained weight and remained normothermic up to the challenge. Guinea pigs that received Candid #1 from any manufacturer elicited neutralizing antibodies to Junin virus (titles from 40 to 81920) and survived to challenge whilst 8/10 animals died in each control group. Data presented demonstrated that Candid #1 vaccines from USA or Argentine manufacturers were equally safe, immunogenic and protective in guinea pigs.

6.
J Virol Methods ; 103(1): 57-66, 2002 May.
Article in English | MEDLINE | ID: mdl-11906733

ABSTRACT

Junin virus is the etiological agent of Argentine hemorrhagic fever, a serious rodent-borne disease. An enzyme-linked immunosorbent assay (ELISA) to detect Junin virus IgG antibodies in rodents was evaluated using sera from 27 Calomys musculinus and five Calomys laucha, inoculated experimentally with a live attenuated strain of this arenavirus. The test performance was compared against an indirect immunofluorescence assay (IFA). The ELISA had a sensitivity and specificity of 100% and a reproducibility of 87.9% for samples with titers above the selected cut-off value. IFA had lower sensitivity (53%) with the same specificity. The ELISA results were similar, whether carried out on whole blood or serum samples, thus eliminating the need for serum separation. A high correlation (K=0.86) between ELISA and IFA results was obtained from 1011 wild sigmodontine and murine rodents collected within and outside of the Argentine hemorrhagic fever endemic area. These results indicate that Junin virus IgG ELISA is the most suitable assay for detection of Junin virus antibodies in rodent samples.


Subject(s)
Antibodies, Viral/blood , Arenaviridae Infections/immunology , Arenaviridae Infections/veterinary , Enzyme-Linked Immunosorbent Assay , Immunoglobulin G/blood , Junin virus/immunology , Muridae/blood , Rodent Diseases/immunology , Animals , Animals, Wild/virology , Arenaviridae Infections/blood , Chlorocebus aethiops , Disease Reservoirs , Fluorescent Antibody Technique, Indirect , Junin virus/growth & development , Muridae/virology , Reproducibility of Results , Rodent Diseases/blood , Rodent Diseases/virology , Sensitivity and Specificity , Vero Cells/virology
SELECTION OF CITATIONS
SEARCH DETAIL