Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
F1000Res ; 12: 533, 2023.
Article in English | MEDLINE | ID: mdl-37965585

ABSTRACT

Background: Successful root canal treatment is influenced by the apical extent of root canal preparation and the eventual root canal filling. Achieving the full working length until the apical constriction, which is usually 0.5 - 1 mm shorter than the anatomical apex, is crucial. Electronic apex locators were used to detect the working length more accurately. There are six generations of electronic apex locators in the market. The selection of the appropriate irrigation with each apex locator for accurate working length determination is not fully investigated. Methods: The actual working lengths of 120 freshly extracted human single-rooted teeth were measured and compared with their working lengths using 3 rd generation (Root ZX) followed by 6 th generation (Raypex 6) apex locators in dry medium, presence of 5.25% sodium hypochlorite, and 2% chlorhexidine, without coronal pre-flaring and after coronal pre-flaring using the same irrigating media. Data were collected, tabulated, and afterward analyzed using one-way ANOVA with post-hoc to evaluate the significant difference in average working length between actual working length, Root ZX, and Raypex 6 apex locator working lengths accuracy. Results: The significant results were shown in roots that were coronally pre-flared and their working lengths were measured in a dry medium using Raypex 6 apex locator. While using the Root ZX apex locator, the most accurate results were shown in roots that were coronally pre-flared and their working lengths were measured while using a chlorhexidine irrigating solution. Conclusions: It is concluded that it is very important to know the specific irrigating medium to be used with each specific electronic apex locator to achieve the most accurate working length results.


Subject(s)
Chlorhexidine , Tooth Apex , Humans , Dental Pulp Cavity , Odontometry , Electronics
2.
Eur J Dent ; 17(1): 76-81, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35196723

ABSTRACT

OBJECTIVE: The current study was designed to assess the bonding strength of EndoSeal MTA and AH Plus sealers after using three irrigation protocols as follows: (1) 17% Ethylenediamine tetraacetic acid, (2) 7% maleic acid, and (3) 37% phosphoric acid. MATERIALS AND METHODS: Push-out bond strength was evaluated for 60 middle root slices of 1-mm thickness each. They were horizontally cut from freshly extracted single-rooted human teeth. A hole in the root canal was made using a carbide round bur of 1.1 mm in diameter in a middle third root slice. Specimens were dipped in 2.5% NaOCl, and then they were grouped into three groups; G1: 17% EDTA, G2: 7% maleic acid, and G3: 37% phosphoric acid as a final irrigant for 3 minutes. Each group was subdivided into two subgroups, according to the type of sealer, either EndoSeal MTA or AH Plus. STATISTICAL ANALYSIS: After the full set of the sealer, the bond strength was evaluated with the push-out test by applying a force to each slice using a plunger with a 1-mm diameter. The one-way Tukey's post hoc test, analysis of variance (ANOVA) test, and Student's t-test were utilized to gather data and statistically evaluate it. RESULTS: The irrigation protocol used exhibited significant influence on the bond strength of EndoSeal MTA and AH Plus sealers. AH Plus sealer subgroups showed the highest bond strength with 7% maleic acid, followed by 37% phosphoric acid, and 17% EDTA. While in the EndoSeal MTA sealer subgroups, the highest bond strength was shown with the 17% EDTA followed by 7% maleic acid and 37% phosphoric acid, respectively. CONCLUSION: The present study revealed that the type of the final irrigant significantly impacts the bond strength of the sealer used. The AH Plus sealer bond strength was improved by using the 7% maleic acid as a final irrigant. In contrast, the EndoSeal MTA sealer showed the best results with the 17% EDTA as a final irrigant.

SELECTION OF CITATIONS
SEARCH DETAIL
...