Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Radiat Isot ; 211: 111407, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38897113

ABSTRACT

Terbium-157 was radiochemically extracted from an irradiated tantalum target. Since the resulting material contained a significant impurity of 158Tb, 157Tb was isotopically purified using laser resonance ionization at the RISIKO mass separator in Mainz and then implanted on an aluminum (Al) foil. The implanted 157Tb was measured by two different calibrated gamma-ray spectrometers to determine photon emission rates. After dissolving the Al foil, a high purity 157Tb solution was obtained. The corresponding activity concentration was determined with a low relative uncertainty of 0.52% through a combination of liquid scintillation counting using the TDCR method and 4π(X,e)(LS)-(X,γ)(CeBr3) coincidence counting. By combining the results from all measurement techniques, emission intensities for K X-rays and gamma-rays were derived and found to be 16.05(31)% and 0.0064(2)%, respectively. The probability for K electron capture of the first forbidden non-unique transition to the ground state was determined to be 17.16(35)%. The probabilities for the electron-capture branch to the excited level and the ground state were found to be 0.084(4)% and 99.916(4)%, respectively. A Q+ value of 60.23(18) keV was estimated based on simplified BetaShape calculations, assuming an allowed transition.

2.
Polymers (Basel) ; 14(9)2022 Apr 28.
Article in English | MEDLINE | ID: mdl-35566971

ABSTRACT

Previously we characterized radiophotoluminescent (RPL) detectors for measuring both fast and thermal neutrons for personal monitoring. The linear response and angular dependence, which satisfies the ISO 21909 standard makes their application possible in neutron dosimetry. The polymer CR-39 track detectors remain one of the most used dosimeters where neutron radiations are to be measured, but the visualization process is time consuming. The difference between results obtained by RPL and CR-39 has been discussed mainly for fast neutrons. The present study has also looked at thermal neutron dosimetry, where we found few results in the literature for CR-39. Our measurements demonstrate that RPL detectors can be advantageously incorporated into a dosimeter to measure thermal neutrons.

SELECTION OF CITATIONS
SEARCH DETAIL
...