Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
Add more filters










Publication year range
1.
Neuromodulation ; 25(8): 1259-1267, 2022 Dec.
Article in English | MEDLINE | ID: mdl-33501705

ABSTRACT

OBJECTIVES: Polymers have emerged as constituent materials for the creation of microscale neural interfaces; however, limitations regarding water permeability, delamination, and material degradation impact polymeric device robustness. Liquid crystal polymers (LCPs) have molecular order like a solid but with the fluidity of a liquid, resulting in a unique material, with properties including low water permeability, chemical inertness, and mechanical toughness. The objective of this article is to review the state-of-the-art regarding the use of LCPs in neural interface applications and discuss challenges and opportunities where this class of materials can advance the field of neural interfaces. MATERIALS AND METHODS: This review article focuses on studies that leverage LCP materials to interface with the nervous system in vivo. A comprehensive literature search was performed using PubMed, Web of Science (Clarivate Analytics), and Google Scholar. RESULTS: There have been recent efforts to create neural interfaces that leverage the material advantages of LCPs. The literature offers examples of LCP as a basis for implantable medical devices and neural interfaces in the form of planar electrode arrays for retinal prosthetic, electrocorticography applications, and cuff-like structures for interfacing the peripheral nerve. In addition, there have been efforts to create penetrating intracortical devices capable of microstimulation and resolution of biopotentials. Recent work with a subclass of LCPs, namely liquid crystal elastomers, demonstrates that it is possible to create devices with features that deploy away from a central implantation site to interface with a volume of tissue while offering the possibility of minimizing tissue damage. CONCLUSION: We envision the creation of novel microscale neural interfaces that leverage the physical properties of LCPs and have the capability of deploying within neural tissue for enhanced integration and performance.


Subject(s)
Peripheral Nerves , Polymers , Humans , Polymers/chemistry , Electrodes , Water , Electrodes, Implanted
2.
Biomaterials ; 277: 121073, 2021 10.
Article in English | MEDLINE | ID: mdl-34419732

ABSTRACT

Polymer toughness is preserved at chronic timepoints in a new class of modulus-changing bioelectronics, which hold promise for commercial chronic implant components such as spinal cord stimulation leads. The underlying ester-free chemical network of the polymer substrate enables device rigidity during implantation, soft, compliant, conforming structures during acute phases in vivo, and gradual stabilization of materials properties chronically, maintaining materials toughness as device stiffness changes. In the past, bioelectronics device designs generally avoided modulus-changing and materials due to the difficulty in demonstrating consistent, predictable performance over time in the body. Here, the acute, and chronic mechanical and chemical properties of a new class of ester-free bioelectronic substrates are described and characterized via accelerated aging at elevated temperatures, with an assessment of their underlying cytotoxicity. Furthermore, spinal cord stimulation leads consisting of photolithographically-defined gold traces and titanium nitride (TiN) electrodes are fabricated on ester-free polymer substrates. Electrochemical properties of the fabricated devices are determined in vitro before implantation in the cervical spinal cord of rat models and subsequent quantification of device stimulation capabilities. Preliminary in vivo evidence demonstrates that this new generation of ester-free, softening bioelectronics holds promise to realize stable, scalable, chronically viable components for bioelectronic medicines of the future.


Subject(s)
Spinal Cord Stimulation , Animals , Electrodes , Esters , Polymers , Prostheses and Implants , Rats , Spinal Cord
3.
Acta Biomater ; 111: 54-64, 2020 07 15.
Article in English | MEDLINE | ID: mdl-32428679

ABSTRACT

Intracortical microelectrode arrays (MEAs) are currently limited in their chronic functionality due partially to the foreign body response (FBR) that develops in regions immediately surrounding the implant (typically within 50-100 µm). Mechanically flexible, polymer-based substrates have recently been explored for MEAs as a way of minimizing the FBR caused by the chronic implantation. Nonetheless, the FBR degrades the ability of the device to record neural activity. We are motivated to develop approaches to deploy multiple recording sites away from the initial site of implantation into regions of tissue outside the FBR zone. Liquid Crystal Elastomers (LCEs) are responsive materials capable of programmable and reversible shape change. These hydrophobic materials are also non-cytotoxic and compatible with photolithography. As such, these responsive materials may be well suited to serve as substrates for smart, implantable electronics. This study explores the feasibility of LCE-based deployable intracortical MEAs. LCE intracortical probes are fabricated on a planar substrate and adopt a 3D shape after being released from the substrate. The LCE probes are then fixed in a planar configuration using polyethylene glycol (PEG). The PEG layer dissolves in physiological conditions, allowing the LCE probe to deploy post-implantation. Critically, we show that LCE intracortical probes will deploy within a brain-like agarose tissue phantom. We also show that deployment distance increases with MEA width. A finite element model was then developed to predict the deformed shape of the deployed probe when embedded in an elastic medium. Finally, LCE-based deployable intracortical MEAs were capable of maintaining electrochemical stability, recording extracellular signals from cortical neurons in vivo, and deploying recording sites greater than 100 µm from the insertion site in vivo. Taken together, these results suggest the feasibility of using LCEs to develop deployable intracortical MEAs. STATEMENT OF SIGNIFICANCE: Deployable MEAs are a recently developed class of neural interfaces that aim to shift the recording sites away from the region of insertion to minimize the negative effects of FBR on the recording performance of MEAs. In this study, we explore LCEs as a potential substrate for deployable MEAs. The novelty of this study lies in the systematic and programmable deployment offered by LCE-based intracortical MEAs. These results illustrate the feasibility and potential application of LCEs as a substrate for deployable intracortical MEAs.


Subject(s)
Elastomers , Liquid Crystals , Electrodes, Implanted , Microelectrodes , Polymers
4.
J Mater Chem B ; 8(29): 6286-6295, 2020 08 07.
Article in English | MEDLINE | ID: mdl-32315020

ABSTRACT

New device architectures favorable for interaction with the soft and dynamic biological tissue are critical for the design of indwelling biosensors and neural interfaces. For the long-term use of such devices within the body, it is also critical that the component materials resist the physiological harsh mechanical and chemical conditions. Here, we describe the design and fabrication of mechanically and chemically robust 3D implantable electronics. This is achieved by using traditional photolithography to pattern electronics on liquid crystal elastomers (LCEs), a class of shape programmable materials. The chemical durability of LCE is evaluated under accelerated in vitro conditions simulating the physiological environment; for example, LCE exhibits less than 1% mass change under a hydrolytic medium simulating >1 year in vivo. By employing twisted nematic LCEs as dynamic substrates, we demonstrate electronics that are fabricated on planar substrates but upon release morph into programmed 3D shapes. These shapes are designed to enable intrinsically low failure strain materials to be extrinsically stretchable. For example, helical multichannel cables for electrode arrays withstand cyclic stretching and buckling over 10 000 cycles at 60% strain while being soaked in phosphate-buffered saline. We envision that these LCE-based electronics can be used for applications in implantable neural interfaces and biosensors.


Subject(s)
Elastomers/chemistry , Electrical Equipment and Supplies , Liquid Crystals/chemistry , Prostheses and Implants , Biosensing Techniques/instrumentation , Equipment Design
5.
J Biomed Mater Res B Appl Biomater ; 108(3): 880-891, 2020 04.
Article in English | MEDLINE | ID: mdl-31353822

ABSTRACT

The deposition and properties of sputtered iridium oxide films (SIROFs) using water vapor as a reactive gas constituent are investigated for their potential as high-charge-capacity neural stimulation electrodes. Systematic investigation through a series of optical and electrochemical measurements reveals that the incorporation of water vapor as a reactive gas constituent, along with oxygen, alters the reduction-oxidation (redox) state of the plasma as well as its morphology and the electrochemical characteristics, including the cathodal charge-storage capacity (CSCc ) and charge-injection capacity (CIC), of the SIROF. An apparent optimal O2 :H2 O gas ratio of 1:3 produced SIROF with a CSCc of 182.0 mC cm-2 µm-1 (median, Q1 = 172.5, Q3 = 193.4, n = 15) and a CIC of 3.57 mC cm-2 (median, Q1 = 2.97, Q3 = 4.58, n = 12) for 300-nm-thick films. These values are higher than those obtained with SIROFs deposited using no water vapor by a factor of 2.3 and 1.7 for the CSCc and CIC, respectively. Additionally, the SIROF showed minimal changes in electrochemical characteristics over 109 pulses of constant current stimulation and showed no indication of cytotoxicity toward primary cortical neurons in a cell viability assay. These results warrant investigation of the chronic recording and stimulation capabilities of the SIROF for implantable microelectrode arrays.


Subject(s)
Electric Stimulation , Electrodes , Iridium/chemistry , Neurons/drug effects , Neurons/metabolism , Animals , Cell Survival , Cells, Cultured , Electrochemistry , Electrodes, Implanted , Electrolytes , Gases , Mass Spectrometry , Materials Testing , Mice , Microelectrodes , Oxidation-Reduction , Oxygen/chemistry , Water
6.
Acta Biomater ; 101: 565-574, 2020 01 01.
Article in English | MEDLINE | ID: mdl-31678740

ABSTRACT

We have characterized the in vitro and in vivo extracellular neural recording and stimulation properties of ruthenium oxide (RuOx) based microelectrodes. Cytotoxicity and functional neurotoxicity assays were carried out to confirm the in vitro biocompatibility of RuOx. Material extract assays, in accordance to ISO protocol "10993-5: Biological evaluation of medical devices", revealed no significant effect on neuronal cell viability or the functional activity of cortical networks. In vitro microelectrode arrays (MEAs), with indium tin oxide (ITO) sites modified with sputtered iridium oxide (IrOx) and RuOx in a single array, were developed for a direct comparison of electrochemical and recording performance of RuOx to ITO and IrOx deposited microelectrode sites. The impedance of the RuOx-coated electrodes measured by electrochemical impedance spectroscopy was notably lower than that of ITO electrodes, resulting in robust extracellular recordings from cortical networks in vitro. We found comparable signal-to-noise ratios (SNRs) for RuOx and IrOx, both significantly higher than the SNR for ITO. RuOx-based MEAs were also fabricated and implanted in the rat motor cortex to demonstrate manufacturability of the RuOx processing and acute recording capabilities in vivo. We observed single-unit extracellular action potentials with a SNR >22, representing a first step for neurophysiological recordings in vivo with RuOx based microelectrodes. STATEMENT OF SIGNIFICANCE: A critical challenge in neural interface technology is the development of microelectrodes that have recording and electrical stimulation capabilities suitable for bidirectional communication between the external electronic device and the nervous system. The present study explores the feasibility and functional capabilities of ruthenium oxide microelectrodes as a neural interface. Significant improvement in electrochemical properties and neuronal recordings are reported when compared to commercially available indium tin oxide and was similar to that of iridium oxide electrodes. The data demonstrate the potential for future development of chronic neural interfaces using ruthenium oxide based microelectrodes for recording and stimulation.


Subject(s)
Brain/physiology , Oxides/pharmacology , Ruthenium/pharmacology , Animals , Cells, Cultured , Cerebral Cortex/embryology , Electric Stimulation , Electrochemical Techniques , Embryo, Mammalian/cytology , Female , Mice, Inbred ICR , Microelectrodes , Neurons/drug effects , Neurotoxins/toxicity , Rats, Long-Evans
7.
ACS Appl Mater Interfaces ; 11(21): 19506-19513, 2019 May 29.
Article in English | MEDLINE | ID: mdl-31070344

ABSTRACT

Traditional electronic devices are rigid, planar, and mechanically static. The combination of traditional electronic materials and responsive polymer substrates is of significant interest to provide opportunities to replace conventional electronic devices with stretchable, 3D, and responsive electronics. Liquid crystal elastomers (LCEs) are well suited to function as such dynamic substrates because of their large strain, reversible stimulus response that can be controlled through directed self-assembly of molecular order. Here, we discuss using LCEs as substrates for electronic devices that are flat during processing but then morph into controlled 3D structures. We design and demonstrate processes for a variety of electronic devices on LCEs including deformation-tolerant conducting traces and capacitors and cold temperature-responsive antennas. For example, patterning twisted nematic orientation within the substrate can be used to create helical electronic devices that stretch up to 100% with less than 2% change in resistance or capacitance. Moreover, we discuss self-morphing LCE antennas which can dynamically change the operating frequency from 2.7 GHz (room temperature) to 3.3 GHz (-65 °C). We envision applications for these 3D, responsive devices in wearable or implantable electronics and in cold-chain monitoring radio frequency identification sensors.

8.
J Neural Eng ; 16(4): 046006, 2019 08.
Article in English | MEDLINE | ID: mdl-31013489

ABSTRACT

OBJECTIVE: Clinical applications of implantable microelectrode arrays are currently limited by device failure due to, in part, mechanical and electrochemical failure modes. To overcome this challenge, there is significant research interest in the exploration of novel array architectures and encapsulation materials. Amorphous silicon carbide (a-SiC) is biocompatible and corrosion resistant, and has recently been employed as a coating on biomedical devices including planar microelectrode arrays. However, to date, the three-dimensional Utah electrode array (UEA) is the only array architecture which has been approved by the food and drug administration (FDA) for long-term human trials. APPROACH: Here, we demonstrate, for the first time, that UEAs can be fabricated with a-SiC encapsulation and sputtered iridium oxide film (SIROF) electrode coatings, and that such arrays are capable of single-unit recordings over a 30 week implantation period in rat motor cortex. Over the same period, we carried out electrochemical measurements, including voltage transients, cyclic voltammetry, and electrochemical impedance spectroscopy (EIS), to evaluate potential failure modes. Furthermore, we evaluated chronic foreign body response via fluorescence immunohistochemistry following device explantation. MAIN RESULTS: During the indwelling period, we observed a reduction in active electrode yield percentage from 94.6 ± 5.4 (week 1) to 16.4 ± 11.5% (week 30). While the average active electrode yield showed a steady reduction, it is noteworthy that 3 out of 8 UEAs recorded greater than 60% active electrode yield at all times through 24 weeks and 1 out of 8 UEAs recorded greater than 60% active electrode yield at all times through the whole implantation period. SIGNIFICANCE: In total, these findings further suggest that a-SiC may serve as a mechanically and electrochemically stable device encapsulation alternative to polymeric coatings such as Parylene-C.


Subject(s)
Carbon Compounds, Inorganic , Coated Materials, Biocompatible , Electrodes, Implanted , Motor Cortex/physiology , Silicon Compounds , Animals , Electrochemical Techniques/instrumentation , Electrochemical Techniques/methods , Extracellular Fluid/physiology , Microelectrodes , Rats , Rats, Long-Evans
9.
Micromachines (Basel) ; 9(8)2018 Aug 20.
Article in English | MEDLINE | ID: mdl-30424349

ABSTRACT

Polymer-based biomedical electronics provide a tunable platform to interact with nervous tissue both in vitro and in vivo. Ultimately, the ability to control functional properties of neural interfaces may provide important advantages to study the nervous system or to restore function in patients with neurodegenerative disorders. Liquid crystal elastomers (LCEs) are a class of smart materials that reversibly change shape when exposed to a variety of stimuli. Our interest in LCEs is based on leveraging this shape change to deploy electrode sites beyond the tissue regions exhibiting inflammation associated with chronic implantation. As a first step, we demonstrate that LCEs are cellular compatible materials that can be used as substrates for fabricating microelectrode arrays (MEAs) capable of recording single unit activity in vitro. Extracts from LCEs are non-cytotoxic (>70% normalized percent viability), as determined in accordance to ISO protocol 10993-5 using fibroblasts and primary murine cortical neurons. LCEs are also not functionally neurotoxic as determined by exposing cortical neurons cultured on conventional microelectrode arrays to LCE extract for 48 h. Microelectrode arrays fabricated on LCEs are stable, as determined by electrochemical impedance spectroscopy. Examination of the impedance and phase at 1 kHz, a frequency associated with single unit recording, showed results well within range of electrophysiological recordings over 30 days of monitoring in phosphate-buffered saline (PBS). Moreover, the LCE arrays are shown to support viable cortical neuronal cultures over 27 days in vitro and to enable recording of prominent extracellular biopotentials comparable to those achieved with conventional commercially-available microelectrode arrays.

10.
J Biomed Mater Res A ; 106(11): 2891-2898, 2018 11.
Article in English | MEDLINE | ID: mdl-30371968

ABSTRACT

Shape memory polymers (SMPs) based on thiol-ene/acrylate formulations are an emerging class of materials with potential applications as structural and/or dielectric coatings for implantable neural interfaces. Here, we report in vitro compatibility studies of three novel thiol-ene/acrylate-based SMP formulations. In vivo cytotoxicity assays were carried out in accordance with International Organization for Standards (ISO) protocol 10993-5, using NCTC clone 929 fibroblasts as well as embryonic cortical cultures. All three SMP formulations passed standardized cytotoxicity assays (>70% normalized cell viability) using both cell types. Functional neurotoxicity assays were carried out using primary cortical networks cultured on substrate-integrated microelectrode arrays (MEAs). We observed significant reduction in cortical network activity in the case of positive control material, but no significant alterations in activity following incubation with SMP material extracts, indicating functional cytocompatibility. Finally, we assessed cell reactivity at the tissue-material interface by performing an in vitro glial scarring assay. Through immunostaining, we observed similar astrocyte-associated (GFAP) mean intensity ratios near nonsoftening SMP-coated and uncoated stainless steel microwires (1.10 ± 0.06 vs. 1.19 ± 0.10), suggesting similar glial cell reactivity. However, we observed decreased mean intensity ratios in the presence of fully softening SMP-coated microwires (1.02 ± 0.04) suggesting reduced glial cell reactivity. Overall, these results indicate that the thiol-ene/acrylate SMP formulations presented here are neither cytotoxic nor neurotoxic, and suggest that fully softening SMP may reduce foreign body response in terms of glial cell reactivity. These findings support further consideration of this class of materials as backbone or insulating materials for implantable neural stimulating/recording devices. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 2891-2898, 2018.


Subject(s)
Acrylates/chemistry , Biocompatible Materials/chemistry , Neurons/cytology , Sulfhydryl Compounds/chemistry , Acrylates/toxicity , Animals , Biocompatible Materials/toxicity , Cell Survival/drug effects , Fibroblasts/cytology , Materials Testing , Mice , Microelectrodes , Prostheses and Implants , Sulfhydryl Compounds/toxicity
11.
J Neurophysiol ; 120(4): 2083-2090, 2018 10 01.
Article in English | MEDLINE | ID: mdl-30020844

ABSTRACT

Multisite implantable electrode arrays serve as a tool to understand cortical network connectivity and plasticity. Furthermore, they enable electrical stimulation to drive plasticity, study motor/sensory mapping, or provide network input for controlling brain-computer interfaces. Neurobehavioral rodent models are prevalent in studies of motor cortex injury and recovery as well as restoration of auditory/visual cues due to their relatively low cost and ease of training. Therefore, it is important to understand the chronic performance of relevant electrode arrays in rodent models. In this report, we evaluate the chronic recording and electrochemical performance of 16-channel Utah electrode arrays, the current state-of-the-art in pre-/clinical cortical recording and stimulation, in rat motor cortex over a period of 6 mo. The single-unit active electrode yield decreased from 52.8 ± 10.0 ( week 1) to 13.4 ± 5.1% ( week 24). Similarly, the total number of single units recorded on all electrodes across all arrays decreased from 106 to 15 over the same time period. Parallel measurements of electrochemical impedance spectra and cathodic charge storage capacity exhibited significant changes in electrochemical characteristics consistent with development of electrolyte leakage pathways over time. Additionally, measurements of maximum cathodal potential excursion indicated that only a relatively small fraction of electrodes (10-35% at 1 and 24 wk postimplantation) were capable of delivering relevant currents (20 µA at 4 nC/ph) without exceeding negative or positive electrochemical potential limits. In total, our findings suggest mainly abiotic failure modes, including mechanical wire breakage as well as degradation of conducting and insulating substrates. NEW & NOTEWORTHY Multisite implantable electrode arrays serve as a tool to record cortical network activity and enable electrical stimulation to drive plasticity or provide network feedback. The use of rodent models in these fields is prevalent. We evaluated chronic recording and electrochemical performance of 16-channel Utah electrode arrays in rat motor cortex over a period of 6 mo. We primarily observed abiotic failure modes suggestive of mechanical wire breakage and/or degradation of insulation.


Subject(s)
Electroencephalography/methods , Motor Cortex/physiology , Animals , Electrochemical Techniques/instrumentation , Electrochemical Techniques/methods , Electrodes, Implanted/standards , Electroencephalography/instrumentation , Male , Microelectrodes/standards , Rats , Signal-To-Noise Ratio
12.
Biomed Microdevices ; 20(2): 48, 2018 06 16.
Article in English | MEDLINE | ID: mdl-29909439

ABSTRACT

Substrate-integrated microelectrode arrays (MEAs) are non-invasive platforms for recording supra-threshold signals, i.e. action potentials or spikes, from a variety of cultured electrically active cells, and are useful for pharmacological and toxicological studies. However, the MEA substrate, which is often fabricated using semiconductor processing technology, presents some challenges to the user. Specifically, the electrode encapsulation, which may consist of a variety of inorganic and organic materials, requires a specific substrate preparation protocol to optimize cell adhesion to the surface. Often, these protocols differ from and are more complex than traditional protocols for in vitro cell culture in polystyrene petri dishes. Here, we describe the fabrication of an MEA with indium tin oxide microelectrodes and a patterned polystyrene electrode encapsulation. We demonstrate the electrochemical stability of the electrodes and encapsulation, and show viable cell culture and in vitro recordings.


Subject(s)
Electrophysiology/instrumentation , Microelectrodes , Neurons/cytology , Polystyrenes , Animals , Female , Mice , Pregnancy , Surface Properties
13.
Neuromodulation ; 20(8): 745-752, 2017 Dec.
Article in English | MEDLINE | ID: mdl-29076214

ABSTRACT

OBJECTIVES: Neural stimulation is well-accepted as an effective therapy for a wide range of neurological disorders. While the scale of clinical devices is relatively large, translational, and pilot clinical applications are underway for microelectrode-based systems. Microelectrodes have the advantage of stimulating a relatively small tissue volume which may improve selectivity of therapeutic stimuli. Current microelectrode technology is associated with chronic tissue response which limits utility of these devices for neural recording and stimulation. One approach for addressing the tissue response problem may be to reduce physical dimensions of the device. "Thinking small" is a trend for the electronics industry, and for implantable neural interfaces, the result may be a device that can evade the foreign body response. MATERIALS AND METHODS: This review paper surveys our current understanding pertaining to the relationship between implant size and tissue response and the state-of-the-art in ultrasmall microelectrodes. A comprehensive literature search was performed using PubMed, Web of Science (Clarivate Analytics), and Google Scholar. RESULTS: The literature review shows recent efforts to create microelectrodes that are extremely thin appear to reduce or even eliminate the chronic tissue response. With high charge capacity coatings, ultramicroelectrodes fabricated from emerging polymers, and amorphous silicon carbide appear promising for neurostimulation applications. CONCLUSION: We envision the emergence of robust and manufacturable ultramicroelectrodes that leverage advanced materials where the small cross-sectional geometry enables compliance within tissue. Nevertheless, future testing under in vivo conditions is particularly important for assessing the stability of thin film devices under chronic stimulation.


Subject(s)
Electrodes, Implanted/trends , Equipment Design/trends , Microelectrodes/trends , Neurons/physiology , Animals , Electrodes, Implanted/standards , Equipment Design/standards , Humans , Microelectrodes/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...