1.
Early Hum Dev ; 166: 105537, 2022 03.
Article in English | MEDLINE | ID: mdl-35091162

ABSTRACT

BACKGROUND: The diagnostic value of ST analysis of the fetal electrocardiogram (fECG) during labor is uncertain. False alarms (ST events) may be explained by physiological variation of the fetal electrical heart axis. Adjusted ST events, based on a relative rather than an absolute rise from baseline, correct for this variation and may improve the diagnostic accuracy of ST analysis. AIMS: Determine the optimal cut-off for relative ST events in fECG to detect fetal metabolic acidosis. STUDY DESIGN: Post-hoc analysis on fECG tracings from the Dutch STAN trial (STAN+CTG branch). SUBJECTS: 1328 term singleton fetuses with scalp ECG tracing during labor, including 10 cases of metabolic acidosis. OUTCOME MEASURES: Cut-off value for relative ST events at the point closest to (0,1) in the receiver operating characteristic (ROC) curve with corresponding sensitivity and specificity. RESULTS: Relative baseline ST events had an optimal cut-off at an increment of 85% from baseline. Relative ST events had a sensitivity of 90% and specificity of 80%. CONCLUSIONS: Adjusting the current definition of ST events may improve ST analysis, making it independent of CTG interpretation.


Subject(s)
Acidosis , Labor, Obstetric , Acidosis/diagnosis , Cardiotocography , Electrocardiography , Female , Fetal Heart , Fetal Monitoring , Heart Rate, Fetal , Humans , Pregnancy
2.
Ultrasound Obstet Gynecol ; 57(2): 292-297, 2021 02.
Article in English | MEDLINE | ID: mdl-32939850

ABSTRACT

OBJECTIVE: To evaluate the rate of preterm birth (PTB) in a subsequent pregnancy in women who had undergone term induction using a Foley catheter compared with prostaglandins. METHODS: This was a follow-up study of two large randomized controlled trials (PROBAAT-1 and PROBAAT-2). In the original trials, women with a term singleton pregnancy with the fetus in cephalic presentation and with an indication for labor induction were randomized to receive either a 30-mL Foley catheter or prostaglandins (vaginal prostaglandin E2 in PROBAAT-1 and oral misoprostol in PROBAAT-2). Data on subsequent ongoing pregnancies > 16 weeks' gestation were collected from hospital charts from clinics participating in this follow-up study. The main outcome measure was preterm birth < 37 weeks' gestation in a subsequent pregnancy. RESULTS: Fourteen hospitals agreed to participate in this follow-up study. Of the 1142 eligible women, 572 had been allocated to induction of labor using a Foley catheter and 570 to induction of labor using prostaglandins. Of these, 162 (14%) were lost to follow-up. In total, 251 and 258 women had a known subsequent pregnancy > 16 weeks' gestation in the Foley catheter and prostaglandin groups, respectively. There were no differences in baseline characteristics between the groups. The overall rate of PTB in a subsequent pregnancy was 9/251 (3.6%) in the Foley catheter group vs 10/258 (3.9%) in the prostaglandin group (relative risk (RR), 0.93; 95% CI, 0.38-2.24), and the rate of spontaneous PTB was 5/251 (2.0%) vs 5/258 (1.9%) (RR, 1.03; 95% CI, 0.30-3.51). CONCLUSION: In women with term singleton pregnancy, induction of labor using a 30-mL Foley catheter is not associated with an increased risk of PTB in a subsequent pregnancy, as compared to induction of labor using prostaglandins. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Subject(s)
Catheters/adverse effects , Labor, Induced , Premature Birth/etiology , Female , Follow-Up Studies , Humans , Netherlands , Pregnancy , Randomized Controlled Trials as Topic , Risk Factors , Urinary Catheterization/adverse effects
3.
BMC Pregnancy Childbirth ; 19(1): 85, 2019 Mar 04.
Article in English | MEDLINE | ID: mdl-30832681

ABSTRACT

BACKGROUND: Double-layer compared to single-layer closure of the uterus after a caesarean section (CS) leads to a thicker myometrial layer at the site of the CS scar, also called residual myometrium thickness (RMT). It possibly decreases the development of a niche, which is an interruption of the myometrium at the site of the uterine scar. Thin RMT and a niche are associated with gynaecological symptoms, obstetric complications in a subsequent pregnancy and delivery and possibly with subfertility. METHODS: Women undergoing a first CS regardless of the gestational age will be asked to participate in this multicentre, double blinded randomised controlled trial (RCT). They will be randomised to single-layer closure or double-layer closure of the uterine incision. Single-layer closure (control group) is performed with a continuous running, unlocked suture, with or without endometrial saving technique. Double-layer closure (intervention group) is performed with the first layer in a continuous unlocked suture including the endometrial layer and the second layer is also continuous unlocked and imbricates the first. The primary outcome is the reported number of days with postmenstrual spotting during one menstrual cycle nine months after CS. Secondary outcomes include surgical data, ultrasound evaluation at three months, menstrual pattern, dysmenorrhea, quality of life, and sexual function at nine months. Structured transvaginal ultrasound (TVUS) evaluation is performed to assess the uterine scar and if necessary saline infusion sonohysterography (SIS) or gel instillation sonohysterography (GIS) will be added to the examination. Women and ultrasound examiners will be blinded for allocation. Reproductive outcomes at three years follow-up including fertility, mode of delivery and complications in subsequent deliveries will be studied as well. Analyses will be performed by intention to treat. 2290 women have to be randomised to show a reduction of 15% in the mean number of spotting days. Additionally, a cost-effectiveness analysis will be performed from a societal perspective. DISCUSSION: This RCT will provide insight in the outcomes of single- compared to double-layer closure technique after CS, including postmenstrual spotting and subfertility in relation to niche development measured by ultrasound. TRIAL REGISTRATION: Dutch Trial Register ( NTR5480 ). Registered 29 October 2015.


Subject(s)
Cesarean Section/methods , Metrorrhagia/etiology , Suture Techniques/adverse effects , Uterus/surgery , Cicatrix/diagnostic imaging , Cicatrix/etiology , Double-Blind Method , Dysmenorrhea/etiology , Endosonography , Female , Fertility , Humans , Menstruation , Obstetric Labor Complications/etiology , Pregnancy , Quality of Life , Randomized Controlled Trials as Topic , Sexuality , Uterus/diagnostic imaging
4.
BJOG ; 121(8): 1005-14, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24405687

ABSTRACT

OBJECTIVE: To assess the effect of red blood cell (RBC) transfusion on quality of life in acutely anaemic women after postpartum haemorrhage. DESIGN: Randomised non-inferiority trial. SETTING: Thirty-seven Dutch university and general hospitals. POPULATION: Women with acute anaemia (haemoglobin 4.8-7.9 g/dl [3.0-4.9 mmol/l] 12-24 hours postpartum) without severe anaemic symptoms or severe comorbidities. METHODS: Women were allocated to RBC transfusion or non-intervention. MAIN OUTCOME MEASURES: Primary outcome was physical fatigue 3 days postpartum (Multidimensional Fatigue Inventory, scale 4-20; 20 represents maximal fatigue). Non-inferiority was demonstrated if the physical fatigue difference between study arms was maximal 1.3. Secondary outcomes were health-related quality of life and physical complications. Health-related quality of life questionnaires were completed at five time-points until 6 weeks postpartum. RESULTS: In all, 521 women were randomised to non-intervention (n = 262) or RBC transfusion (n = 259). Mean physical fatigue score at day 3 postpartum, adjusted for baseline and mode of delivery, was 0.8 lower in the RBC transfusion arm (95% confidence interval: 0.1-1.5, P = 0.02) and at 1 week postpartum was 1.06 lower (95% confidence interval: 0.3-1.8, P = 0.01). A median of two RBC units was transfused in the RBC transfusion arm. In the non-intervention arm, 33 women received RBC transfusion, mainly because of anaemic symptoms. Physical complications were comparable. CONCLUSIONS: Statistically, non-inferiority could not be demonstrated as the confidence interval crossed the non-inferiority boundary. Nevertheless, with only a small difference in physical fatigue and no differences in secondary outcomes, implementation of restrictive management seems clinically justified.


Subject(s)
Anemia/therapy , Erythrocyte Transfusion/standards , Fatigue/therapy , Maternal Welfare , Postpartum Hemorrhage/therapy , Adult , Anemia/etiology , Fatigue/etiology , Female , Follow-Up Studies , Hospitals, General , Hospitals, University , Humans , Netherlands , Practice Guidelines as Topic , Quality of Life , Risk Assessment , Severity of Illness Index , Treatment Outcome
5.
BJOG ; 120(8): 987-95, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23530729

ABSTRACT

OBJECTIVE: To assess the economic consequences of labour induction with Foley catheter compared to prostaglandin E2 gel. DESIGN: Economic evaluation alongside a randomised controlled trial. SETTING: Obstetric departments of one university and 11 teaching hospitals in the Netherlands. POPULATION: Women scheduled for labour induction with a singleton pregnancy in cephalic presentation at term, intact membranes and an unfavourable cervix; and without previous caesarean section. METHODS: Cost-effectiveness analysis from a hospital perspective. MAIN OUTCOME MEASURES: We estimated direct medical costs associated with healthcare utilisation from randomisation to 6 weeks postpartum. For caesarean section rate, and maternal and neonatal morbidity we calculated the incremental cost-effectiveness ratios, which represent the costs to prevent one of these adverse outcomes. RESULTS: Mean costs per woman in the Foley catheter group (n = 411) and in the prostaglandin E2 gel group (n = 408), were €3297 versus €3075, respectively, with an average difference of €222 (95% confidence interval -€157 to €633). In the Foley catheter group we observed higher costs due to longer labour ward occupation and less cost related to induction material and neonatal admissions. Foley catheter induction showed a comparable caesarean section rate compared with prostaglandin induction, therefore the incremental cost-effectiveness ratio was not informative. Foley induction resulted in fewer neonatal admissions (incremental cost-effectiveness ratio €2708) and asphyxia/postpartum haemorrhage (incremental cost-effectiveness ratios €5257) compared with prostaglandin induction. CONCLUSIONS: Foley catheter and prostaglandin E2 labour induction generate comparable costs.


Subject(s)
Catheters/statistics & numerical data , Cesarean Section/statistics & numerical data , Dinoprostone/administration & dosage , Dinoprostone/economics , Labor, Induced/methods , Urinary Catheterization/economics , Administration, Intravaginal , Adult , Catheters/economics , Cesarean Section/economics , Cost-Benefit Analysis , Female , Humans , Labor, Induced/economics , Netherlands , Pregnancy , Vaginal Creams, Foams, and Jellies/administration & dosage
6.
BJOG ; 119(11): 1410-6, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22827811

ABSTRACT

OBJECTIVE: To investigate the association between maternal intrapartum fever and ST-waveform changes of the fetal electrocardiogram. DESIGN: Retrospective cohort study. SETTING: Three academic and six non-academic teaching hospitals in the Netherlands. POPULATION: Labouring women with a high-risk singleton pregnancy in cephalic position beyond 36 weeks of gestation. METHODS: We studied 142 women with fever (≥38.0°C) during labour and 141 women with normal temperature who had been included in two previous studies. In both groups, we counted the number and type of ST-events and classified them as significant (intervention needed) or not significant, based on STAN(®) clinical guidelines. MAIN OUTCOME MEASURES: Number and type of ST-events. RESULTS: Both univariable and multivariable regression analysis showed no association between the presence of maternal intrapartum fever and the number or type of ST-events. CONCLUSIONS: Maternal intrapartum fever is not associated with ST-segment changes of the fetal electrocardiogram. Interpretation of ST-changes in labouring women with fever should therefore not differ from other situations.


Subject(s)
Arrhythmias, Cardiac/etiology , Electrocardiography/methods , Fetal Diseases/etiology , Fetal Monitoring/methods , Fever/complications , Pregnancy Complications , Arrhythmias, Cardiac/diagnosis , Cohort Studies , Female , Fetal Diseases/physiopathology , Heart Rate, Fetal , Humans , Labor, Obstetric , Logistic Models , Netherlands , Pregnancy , Pregnancy Complications/diagnosis , Pregnancy, High-Risk , Retrospective Studies , Risk Factors
7.
BJOG ; 118(10): 1239-46, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21668767

ABSTRACT

OBJECTIVES: To evaluate the recommendations for additional fetal blood sampling (FBS) when using ST-analysis of the fetal electrocardiogram. DESIGN: Prospective cohort study. SETTING: Three academic and six non-academic teaching hospitals in the Netherlands. POPULATION: Labouring women with a high-risk singleton pregnancy in cephalic position beyond 36 weeks of gestation. METHODS: In labouring women allocated to the STAN® arm of a previously published randomised controlled trial who underwent one or more FBS during delivery, we assessed whether FBS was performed according to the trial protocol and how fetal acidosis, defined as an FBS pH < 7.20, was related to ST-waveform analysis. MAIN OUTCOME MEASURES: The number of FBS showing fetal acidosis, related to the different STAN® criteria where additional FBS is recommended. RESULTS: Among 2827 women monitored with STAN®, 297 underwent FBS, of whom 171 (57.6%) were performed according to the predefined criteria and 126 were performed in absence of these criteria. In the first group, rates of fetal acidosis (pH < 7.20) were two of 18, none of nine, 12 of 111 and three of 33 when FBS was taken for abnormal cardiotocogram (CTG) at the start, intermediary CTG at the start, abnormal CTG >60 minutes, and poor electrocardiogram quality, respectively. When the predefined criteria were not met and ST-analysis showed no ST-events, only two incidents of fetal acidosis were seen. CONCLUSIONS: The performance of FBS is valuable in the advised STAN® criteria. When these criteria are not met, performance of FBS does not seem helpful in the detection of fetal acidosis.


Subject(s)
Acidosis/diagnosis , Electrocardiography , Fetal Blood/chemistry , Fetal Diseases/diagnosis , Fetal Heart/physiology , Fetal Monitoring/methods , Cohort Studies , Female , Humans , Labor, Obstetric , Pregnancy , Prospective Studies
8.
Acta Neurol Scand ; 123(6): 430-3, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21492099

ABSTRACT

BACKGROUND: In current literature, no data on safety in pregnancy for new drugs in the treatment of multiple sclerosis (MS) like natalizumab (Tysabri®), a humanized monoclonal antibody against α4 integrins, are yet available. In the management of MS, natalizumab is the first monoclonal antibody approved to the market. METHODS: We describe the pregnancy and outcome in two women with MS using natalizumab. The first patient used it in the periconceptional period, and the second patient used it in both the periconceptional period and throughout gestation. RESULTS: The antenatal course of the first patient was complicated by an exacerbation of MS. The second patient did not experience MS relapses during pregnancy, while still using natalizumab. The newborns did not show any abnormalities postnatal and at 6 weeks' follow-up. CONCLUSIONS: This is the first detailed report on pregnancy and delivery of two babies after maternal treatment of MS with natalizumab. From the small number of cases on the usage of natalizumab during pregnancy in literature, we cannot conclude whether the use of natalizumab is safe, and long-term effects are not known. Further research is needed to establish the exact effects on pregnancy and intrauterine development as well as the long-term effects. Prenatal counseling with thorough explanation of the risks and careful decision making is advisable.


Subject(s)
Antibodies, Monoclonal, Humanized/administration & dosage , Antibodies, Monoclonal, Humanized/adverse effects , Immunologic Factors/administration & dosage , Immunologic Factors/adverse effects , Multiple Sclerosis/drug therapy , Adult , Apgar Score , Female , Humans , Infant, Newborn , Integrin alpha4/immunology , Multiple Sclerosis/immunology , Natalizumab , Pregnancy , Prenatal Exposure Delayed Effects , Secondary Prevention , Treatment Outcome
9.
Ned Tijdschr Geneeskd ; 152(34): 1876-81, 2008 Aug 23.
Article in Dutch | MEDLINE | ID: mdl-18788679

ABSTRACT

OBJECTIVE: To evaluate the diagnostic additional value of routine alpha-foetoprotein (AFP) assessment in amniotic fluid for the detection of neural tube defects (NTDs), compared with week 20 ultrasonographic examination. DESIGN: Retrospective. METHOD: We retrospectively determined AFP concentrations in amniotic fluid obtained from 7981 women who had undergone amniocentesis for karyotyping and AFP assessment. An AFP concentration greater than 2.5 times the median was considered abnormal. Women were categorised into 4 groups based on the indication for invasive prenatal diagnostic assessment: advanced maternal age (group I; n = 6179), increased risk of foetal NTDs (group II; n = 258), ultrasonographically confirmed foetal NTDs (group III; n = 55) or other indications (group IV; n = 1489). RESULTS: In group I, 18 of 6179 samples had increased AFP levels (0.3%), 2 of which were associated with NTDs. In group II, 2 of 258 samples had increased AFP levels (0.8%); both were associated with NTDs. Increased AFP levels were found in 44 of 55 samples from group III (80%), and 223 of 1489 samples from group IV (15.0%). CONCLUSION: Routine assessment of AFP in amniotic fluid based on advanced maternal age provides little additional value in the detection of NTDs beyond that of week 20 ultrasound.

10.
Prenat Diagn ; 23(13): 1042-4, 2003 Dec 30.
Article in English | MEDLINE | ID: mdl-14691988

ABSTRACT

OBJECTIVES: To evaluate at what gestational age fetal DNA can reliably be detected at the earliest in maternal plasma. METHODS: We performed consecutive blood sampling in the first trimester of pregnancy in 17 women who were pregnant after in vitro fertilization (IVF) or intrauterine insemination (IUI). DNA was isolated and the Y-chromosome specific SRY was amplified by real-time polymerase chain reaction (PCR). We likewise studied 31 women prior to invasive prenatal diagnosis procedures for test validation purposes. All test results were compared to cytogenetic sex or sex at birth. RESULTS: The earliest SRY detection was at a gestational age of 5 weeks and 2 days. In none of 4 pregnancies ending in a miscarriage was SRY detected. We detected SRY in maternal plasma in 1 of 2 patients (50%) carrying a male fetus at a gestational age of 5 weeks, in 4 of 5 (80%) at a gestational age of 7 weeks, in 4 of 4 (100%) at a gestational age of 9 weeks. In all 7 women pregnant with a male fetus, the correct fetal sex was detected by 10 weeks. In none of the 6 patients who delivered a girl was SRY detected. In the validation group, SRY was detected in 13 of the 13 male, and none of the 18 female fetuses. CONCLUSIONS: We conclude that real-time PCR of the SRY gene promises to be a reliable technique for early fetal sexing in maternal plasma.


Subject(s)
DNA/analysis , Genes, sry/genetics , Gestational Age , Sex Determination Analysis/methods , DNA/blood , Female , Humans , Male , Polymerase Chain Reaction/methods , Pregnancy , Pregnancy Trimester, First/blood , Reproducibility of Results
11.
J Matern Fetal Neonatal Med ; 11(2): 80-3, 2002 Feb.
Article in English | MEDLINE | ID: mdl-12375547

ABSTRACT

OBJECTIVES: Fetal pulse oximetry was performed during labor in high-risk cases for fetal distress to determine the diagnostic value of this method. METHODS: The fetal SpO2 values were blinded from the obstetrician so that these values did not influence clinical decisions. Mean and lowest SpO2 measurements for the last 30 min prior to either fetal scalp blood sampling or delivery were correlated with scalp pH or pH from the umbilical artery. RESULTS: No significant correlation was found between pH and mean fetal oxygen saturation (correlation coefficient -0.02, p = 0.9). There was no significant correlation between pH and lowest fetal oxygen saturation (correlation coefficient 0.04, p = 0.84). Concerning the feasibility of the method, we found that only 23 of 65 included patients were suitable for analysis; in 20% of cases, we were not able to perform a SpO2 measurement. CONCLUSIONS: None of three cases with pH below 7.05 would have been detected using mean SpO2 over the last 30 min prior to fetal scalp blood sampling or delivery. Only one case would have been detected using the lowest SpO2 measurement over this period. We conclude that fetal SpO2 measurements during labor are of poor diagnostic value, with a disappointing feasibility and therefore are not ready for implementing into daily clinical practice.


Subject(s)
Fetal Blood/chemistry , Fetal Monitoring , Oximetry , Oxygen/blood , Bradycardia/blood , Female , Fetal Distress/blood , Gestational Age , Heart Rate, Fetal , Humans , Hydrogen-Ion Concentration , Labor, Obstetric , Male , Netherlands , Pre-Eclampsia/blood , Pregnancy , Pregnancy, Prolonged/blood , Scalp/blood supply , Umbilical Arteries
SELECTION OF CITATIONS