Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Med Biol Eng Comput ; 58(5): 1069-1078, 2020 May.
Article in English | MEDLINE | ID: mdl-32157593

ABSTRACT

Holter recordings are widely used to detect cardiac events that occur transiently, such as ischemic events. Much effort has been made to detect early ischemia, thus preventing myocardial infarction. However, after detection, classification of ischemia has still not been fully solved. The main difficulty relies on the false positives produced because of non-ischemic events, such as changes in the heart rate, the intraventricular conduction or the cardiac electrical axis. In this work, the classification of ischemic and non-ischemic events from the long-term ST database has been improved, using novel spectral parameters based on the continuous wavelet transform (CWT) together with temporal parameters (such as ST level and slope, T wave width and peak, R wave peak, QRS complex width). This was achieved by using a nearest neighbour classifier of six neighbours. Results indicated a sensitivity and specificity of 84.1% and 92.9% between ischemic and non-ischemic events, respectively, resulting a 10% increase of the sensitivity found in the literature. Extracted features based on the CWT applied on the ECG in the frequency band 0.5-4 Hz provided a substantial improvement in classifying ischemic and non-ischemic events, when comparing with the same classifier using only temporal parameters. Graphical Abstract In this work it is improved the classification of ischemic and non-ischemic events. The main difficulty of ischemic detectors relies on the false positives produced because of non-ischemic events. After a preprocessing stage, temporal and spectral parameters are extracted from events of the Long Term ST Database. The novel parameters proposed in this work are extracted from the Continuous Wavelet Transform. A nearest Neighbor Classifier is used, obtaining a sensitivity and specificity of 84.1% and 92.9%, respectively.


Subject(s)
Electrocardiography, Ambulatory , Myocardial Ischemia , Wavelet Analysis , Adult , Aged , Electrocardiography, Ambulatory/classification , Electrocardiography, Ambulatory/methods , Female , Heart Rate/physiology , Humans , Male , Middle Aged , Myocardial Ischemia/diagnosis , Myocardial Ischemia/physiopathology
2.
J Appl Physiol (1985) ; 124(3): 646-652, 2018 03 01.
Article in English | MEDLINE | ID: mdl-28935830

ABSTRACT

Heart rate variability (HRV) analysis is widely used to investigate the autonomic regulation of the cardiovascular system. HRV is often analyzed using RR time series, which can be affected by different types of artifacts. Although there are several artifact correction methods, there is no study that compares their performances in actual experimental contexts. This work aimed to evaluate the impact of different artifact correction methods on several HRV parameters. Initially, 36 ECG recordings of control rats or rats with heart failure or hypertension were analyzed to characterize artifact occurrence rates and distributions, to be mimicked in simulations. After a rigorous analysis, only 16 recordings ( n = 16) with artifact-free segments of at least 10,000 beats were selected. RR interval losses were then simulated in the artifact-free (reference) time series according to real observations. Correction methods applied to simulated series were deletion, linear interpolation, cubic spline interpolation, modified moving average window, and nonlinear predictive interpolation. Linear (time- and frequency-domain) and nonlinear HRV parameters were calculated from corrupted-corrected time series, as well as for reference series to evaluate the accuracy of each correction method. Results show that NPI provides the overall best performance. However, several correction approaches, for example the simple deletion procedure, can provide good performance in some situations, depending on the HRV parameters under consideration. NEW & NOTEWORTHY This work analyzes the performance of some correction techniques commonly applied to the missing beats problem in RR time series. From artifact-free RR series, spurious values were inserted based on actual data of experimental settings. We intend our work to be a guide to show how artifacts should be corrected to preserve as much as possible the original heart rate variability properties.


Subject(s)
Artifacts , Electrocardiography , Heart Rate , Animals , Male , Rats, Wistar
SELECTION OF CITATIONS