Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
J Imaging Inform Med ; 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38864947

ABSTRACT

Life-threatening acute aortic dissection (AD) demands timely diagnosis for effective intervention. To streamline intrahospital workflows, automated detection of AD in abdominal computed tomography (CT) scans seems useful to assist humans. We aimed at creating a robust convolutional neural network (CNN)-based pipeline capable of real-time screening for signs of abdominal AD in CT. In this retrospective study, abdominal CT data from AD patients presenting with AD and from non-AD patients were collected (n 195, AD cases 94, mean age 65.9 years, female ratio 35.8%). A CNN-based algorithm was developed with the goal of enabling a robust, automated, and highly sensitive detection of abdominal AD. Two sets from internal (n = 32, AD cases 16) and external sources (n = 1189, AD cases 100) were procured for validation. The abdominal region was extracted, followed by the automatic isolation of the aorta region of interest (ROI) and highlighting of the membrane via edge extraction, followed by classification of the aortic ROI as dissected/healthy. A fivefold cross-validation was employed on the internal set, and an ensemble of the 5 trained models was used to predict the internal and external validation set. Evaluation metrics included receiver operating characteristic curve (AUC) and balanced accuracy. The AUC, balanced accuracy, and sensitivity scores of the internal dataset were 0.932 (CI 0.891-0.963), 0.860, and 0.885, respectively. For the internal validation dataset, the AUC, balanced accuracy, and sensitivity scores were 0.887 (CI 0.732-0.988), 0.781, and 0.875, respectively. Furthermore, for the external validation dataset, AUC, balanced accuracy, and sensitivity scores were 0.993 (CI 0.918-0.994), 0.933, and 1.000, respectively. The proposed automated pipeline could assist humans in expediting acute aortic dissection management when integrated into clinical workflows.

2.
Diagnostics (Basel) ; 14(11)2024 May 29.
Article in English | MEDLINE | ID: mdl-38893656

ABSTRACT

The clinical use of photon-counting CT (PCCT) allows for the generation of virtual non-contrast (VNC) series from contrast-enhanced images. In routine clinical practice, specific issues such as ruling out acute bleeding require non-contrast images. The aim of this study is to evaluate the use of PCCT-derived VNC reconstructions in abdominal imaging. PCCT scans of 17 patients including early arterial, portal venous and native sequences were enrolled. VNC reconstructions have been calculated. In every sequence and VNC reconstruction, 10 ROIs were measured (portal vein, descending aorta, inferior vena cava, liver parenchyma, spleen parenchyma, erector spinae muscle, subcutaneous adipose tissue, first lumbar vertebral body, air, and psoas muscle) and density values were compared. The VNC reconstructions show significant changes in density compared to the contrast-enhanced images. However, there were no significant differences present between the true non-contrast (TNC) and any VNC reconstructions in the observed organs and vessels. Significant differences (p < 0.05) between the measured mean density values in the TNC versus VNC reconstructions were found in fat and bone tissue. The PCCT-derived VNC reconstructions seemed to be comparable to the TNC images, despite some deviations shown in the adipose tissue and bone structures. However, the further benefits in terms of specific clinical issues need to be evaluated.

3.
J Vasc Interv Radiol ; 2024 May 14.
Article in English | MEDLINE | ID: mdl-38754759

ABSTRACT

PURPOSE: To characterize the relationship between ablation zone volume (AZV) and microwave ablation (MWA) energy in an in vivo porcine liver model following arterial embolization. MATERIALS AND METHODS: With Institutional Animal Care and Use Committee (IACUC) approval, 11 female swine underwent either right (n = 5) or left (n = 6) hepatic artery embolization under fluoroscopic guidance. Subsequently, ultrasound (US)-guided MWA was performed in each liver segment (left lateral, left medial, right medial, and right lateral) at either 30 W (n = 4 lobes), 60 W (n = 4), 65 W (n = 20), 90 W (n = 8), 120 W (n = 4), or 140 W (n = 4) continuously for 5 minutes. Postprocedural volumetric segmentation was performed on standardized multiphase T1 magnetic resonance (MR) imaging sequences. RESULTS: Mean AZVs in embolized lobes (15.8 mL ± SD 10.6) were significantly larger than those in nonembolized lobes (11.2 mL ± SD 6.5, P < .01). MWA energy demonstrated significant positive linear correlation with both embolized (R2 = 0.66, P < .01) and nonembolized (R2 = 0.64, P < .01) lobes. The slope of the linear models corresponded to a 0.95 mL/kJ (SD ± 0.16) and 0.54 mL/kJ (SD ± 0.09) increase in ablation volume per applied kilojoule of energy (E) in embolized and nonembolized lobes, respectively. In the multivariate model, embolization status significantly modified the relationship between E and AZV as described by the following interaction term: 0.42∗E∗(embolization status) (P = .031). CONCLUSIONS: Linear models demonstrated a near 1.8-fold increase in ratio of AZV per unit E, R(AZV:E), when applied to embolized lobes relative to nonembolized lobes. Absolute AZV differences between embolized and nonembolized lobes were greater at higher-power MWA.

4.
Front Neurol ; 15: 1358145, 2024.
Article in English | MEDLINE | ID: mdl-38487327

ABSTRACT

Background and purpose: Mobile stroke units (MSU) have been demonstrated to improve prehospital stroke care in metropolitan and rural regions. Due to geographical, social and structural idiosyncrasies of the German city of Mannheim, concepts of established MSU services are not directly applicable to the Mannheim initiative. The aim of the present analysis was to identify major determinants that need to be considered when initially setting up a local MSU service. Methods: Local stroke statistics from 2015 to 2021 were analyzed and circadian distribution of strokes and local incidence rates were calculated. MSU patient numbers and total program costs were estimated for varying operating modes, daytime coverage models, staffing configurations which included several resource sharing models with the hospital. Additional case-number simulations for expanded catchment areas were performed. Results: Median time of symptom onset of ischemic stroke patients was 1:00 p.m. 54.3% of all stroke patients were admitted during a 10-h time window on weekdays. Assuming that MSU is able to reach 53% of stroke patients, the average expected number of ischemic stroke patients admitted to MSU would be 0.64 in a 10-h shift each day, which could potentially be increased by expanding the MSU catchment area. Total estimated MSU costs amounted to € 815,087 per annum. Teleneurological assessment reduced overall costs by 11.7%. Conclusion: This analysis provides a framework of determinants and considerations to be addressed during the design process of a novel MSU program in order to balance stroke care improvements with the sustainable use of scarce resources.

5.
JAMA Netw Open ; 6(12): e2346113, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38055279

ABSTRACT

Importance: Postpancreatectomy hemorrhage (PPH) due to postoperative pancreatic fistula (POPF) is a life-threatening complication after pancreatoduodenectomy. However, there is no prediction tool for early identification of patients at high risk of late PPH. Objective: To develop and validate a prediction model for PPH. Design, Setting, and Participants: This retrospective prognostic study included consecutive patients with clinically relevant POPF who underwent pancreatoduodenectomy from January 1, 2009, to May 20, 2023, at the University Hospital Mannheim (derivation cohort), and from January 1, 2012, to May 31, 2022, at the University Hospital Dresden (validation cohort). Data analysis was performed from May 30 to July 29, 2023. Exposure: Clinical and radiologic features of PPH. Main Outcomes and Measures: Accuracy of a predictive risk score of PPH. A multivariate prediction model-the hemorrhage risk score (HRS)-was established in the derivation cohort (n = 139) and validated in the validation cohort (n = 154). Results: A total of 293 patients (187 [64%] men; median age, 69 [IQR, 60-76] years) were included. The HRS comprised 4 variables with associations: sentinel bleeding (odds ratio [OR], 35.10; 95% CI, 5.58-221.00; P < .001), drain fluid culture positive for Candida species (OR, 14.40; 95% CI, 2.24-92.20; P < .001), and radiologic proof of rim enhancement of (OR, 12.00; 95% CI, 2.08-69.50; P = .006) or gas within (OR, 12.10; 95% CI, 2.22-65.50; P = .004) a peripancreatic fluid collection. Two risk categories were identified with patients at low risk (0-1 points) and high risk (≥2 points) to develop PPH. Patients with PPH were predicted accurately in the derivation cohort (C index, 0.97) and validation cohort (C index 0.83). The need for more invasive PPH management (74% vs 34%; P < .001) and severe complications (49% vs 23%; P < .001) were more frequent in high-risk patients compared with low-risk patients. Conclusions and Relevance: In this retrospective prognostic study, a robust prediction model for PPH was developed and validated. This tool may facilitate early identification of patients at high risk for PPH.


Subject(s)
Candida , Data Analysis , Male , Humans , Aged , Female , Retrospective Studies , Risk Factors , Hospitals, University , Postoperative Complications/epidemiology , Postoperative Complications/etiology
6.
Eur Radiol ; 33(11): 7840-7848, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37338555

ABSTRACT

OBJECTIVES: To investigate the effect of a device-assisted suction against resistance Mueller maneuver (MM) on transient interruption of contrast (TIC) in the aorta and pulmonary trunk (PT) on computed tomography pulmonary angiogram (CTPA). METHODS: In this prospective single-center study, 150 patients with suspected pulmonary artery embolism were assigned randomly with two different breathing maneuvers (Mueller maneuver (MM) or standard end-inspiratory breath-hold command (SBC)) during routine CTPA. The MM was performed using a patented prototype (Contrast Booster™) which allows both the patient by means of visual feedback and the medical staff in the CT scanning room to monitor whether the patient is sucking sufficiently or not. Mean Hounsfield attenuation in descending aorta and PT was measured and compared. RESULTS: Overall, patients with MM showed an attenuation of 338.24 HU in the pulmonary trunk, compared to 313.71 HU in SBC (p = 0.157). In the aorta, the values for MM were lower compared to SBC (134.42 HU vs. 177.83 HU, p = 0.001). The TP-aortic ratio was significantly higher in the MM group at 3.86 compared to the SBC group at 2.26, p = 0.001. TIC phenomenon was absent in the MM group, whereas it was present in 9 patients (12.3%) in the SBC group (p = 0.005). Overall contrast was better on all levels for MM (p < 0.001). The presence of breathing artifacts was higher in the MM group (48.1% vs. 30.1%, p = 0.038), without clinical consequence. CONCLUSIONS: Performing the MM with the application of the prototype is an effective way of preventing the TIC phenomenon during i.v. contrast-enhanced CTPA scanning compared to the standard end-inspiratory breathing command. CLINICAL RELEVANCE: Compared to standard end-inspiratory breathing command, the device-assisted Mueller maneuver (MM) improves contrast enhancement and prevents the transient interruption of contrast (TIC) phenomenon in CTPA. Therefore, it may offer optimized diagnostic workup and timely treatment for patients with pulmonary embolism. KEY POINTS: • Transient interruption of contrast (TIC) may impair image quality in CTPA. • Mueller Maneuver using a device prototype could lower the rate of TIC. • Device application in clinical routine may increase diagnostic accuracy.


Subject(s)
Pulmonary Embolism , Tomography, X-Ray Computed , Humans , Suction , Prospective Studies , Tomography, X-Ray Computed/methods , Pulmonary Artery/diagnostic imaging , Pulmonary Embolism/diagnostic imaging , Lung/diagnostic imaging , Contrast Media
7.
J Vasc Interv Radiol ; 34(2): 253-260, 2023 02.
Article in English | MEDLINE | ID: mdl-36368517

ABSTRACT

PURPOSE: The objectives of this study were to assess the utility of dynamic contrast-enhanced magnetic resonance (MR) imaging in quantifying parenchymal perfusional changes after embolization and to characterize the association between pharmacokinetic (PK) parameters and final microwave ablation volume. MATERIALS AND METHODS: PK parameters from dynamic contrast-enhanced MR imaging were used to quantify perfusional changes in the liver after transarterial embolization of the right or left lobe in a swine liver model (n = 5). Each animal subject subsequently underwent microwave ablation (60 W for 5 minutes) of the embolized and nonembolized liver lobes. Changes in PK parameters from dynamic contrast-enhanced MR imaging were correlated with their respective final microwave ablation volumes in each liver lobe. RESULTS: Microwave ablation volumes of embolized liver lobes were significantly larger than those of nonembolized liver lobes (28.0 mL ± 6.2 vs 15.1 mL ± 5.2, P < .001). PK perfusion parameters were significantly lower in embolized liver lobes than in nonembolized liver lobes (Ktrans = 0.69 min-1 ± 0.15 vs 1.52 min-1 ± 0.37, P < .001; kep = 0.69 min-1 ± 0.19 vs 1.54 min-1 ± 0.42, P < .001). There was a moderate but significant correlation between normalized kep and ablation volume, with each unit increase in normalized kep corresponding to a 9.8-mL decrease in ablation volume (P = .035). CONCLUSIONS: PK-derived parameters from dynamic contrast-enhanced MR imaging can be used to quantify perfusional changes after transarterial embolization and are directly inversely correlated with final ablation volume.


Subject(s)
Embolization, Therapeutic , Liver , Swine , Animals , Liver/diagnostic imaging , Liver/surgery , Liver/pathology , Magnetic Resonance Imaging/methods , Perfusion , Embolization, Therapeutic/adverse effects
8.
J Telemed Telecare ; : 1357633X221140951, 2022 Dec 09.
Article in English | MEDLINE | ID: mdl-36484406

ABSTRACT

BACKGROUND AND PURPOSE: To simulate patient-level costs, analyze the economic potential of telemedicine-based mobile stroke units for acute prehospital stroke care, and identify major determinants of cost-effectiveness, based on two recent prospective trials from the United States and Germany. METHODS: A Markov decision model was developed to simulate lifetime costs and outcomes of mobile stroke unit. The model compares diagnostic and therapeutic pathways of ischemic stroke, hemorrhagic stroke, and stroke mimic patients by conventional care or by mobile stroke units. The treatment outcomes were derived from the B_PROUD and the BEST-mobile stroke unit trials and further input parameters were derived from recent literature. Uncertainty was addressed by deterministic and probabilistic sensitivity analyses. A lifetime horizon based on the US healthcare system was adopted to evaluate different cost thresholds for mobile stroke unit and the resulting cost-effectiveness. Willingness-to-pay thresholds were set at 1x and 3x gross domestic product per capita, as recommended by the World Health Organization. RESULTS: In the base case scenario, mobile stroke unit care yielded an incremental gain of 0.591 quality-adjusted life years per dispatch. Mobile stroke unit was highly cost-effective up to a maximum average cost of 43,067 US dollars per patient. Sensitivity analyses revealed that MSU cost-effectiveness is mainly affected by reduction of long-term disability costs. Also, among other parameters, the rate of stroke mimics patients diagnosed by MSU plays an important role. CONCLUSION: This study demonstrated that mobile stroke unit can possibly be operated on an excellent level of cost-effectiveness in urban areas in North America with number of stroke mimic patients and long-term stroke survivor costs as major determinants of lifetime cost-effectiveness.

9.
J Am Coll Radiol ; 19(6): 733-743, 2022 06.
Article in English | MEDLINE | ID: mdl-35476943

ABSTRACT

PURPOSE: The aim of this study was to investigate whether prostatic artery embolization (PAE) can be considered a long-term cost-effective treatment option in patients with lower urinary tract symptoms secondary to benign prostatic hyperplasia in comparison to transurethral resection of the prostate (TURP). METHODS: The in-hospital costs of PAE and TURP in the United States were obtained from a recent cost analysis. Clinical outcomes including nature and rate of adverse events for TURP and PAE along with rates of retreatment because of complications or clinical failure were obtained from peer-reviewed literature. A decision tree-based Markov model was created, analyzing long-term cost-effectiveness for TURP and PAE from a US health care sector perspective. Cost-effectiveness over a time frame of 5 years was estimated while assuming a willingness to pay of $50,000 per quality-adjusted life-year (QALY). The primary outcome was incremental cost-effectiveness ratio. RESULTS: PAE resulted in overall cost of $6,464.92 and an expected outcome of 4.566 QALYs. In comparison, TURP cost $9,221.09 and resulted in expected outcome of 4.577 QALYs per treatment. The incremental cost-effectiveness ratio for TURP was $247,732.65 per QALY. On the basis of the willingness-to-pay threshold, PAE is cost effective compared with TURP. CONCLUSIONS: On the basis of our model, PAE in comparison with TURP can be regarded as a cost-effective treatment option for patients with lower urinary tract symptoms within the US health care system.


Subject(s)
Embolization, Therapeutic , Lower Urinary Tract Symptoms , Prostatic Hyperplasia , Transurethral Resection of Prostate , Arteries , Cost-Benefit Analysis , Humans , Lower Urinary Tract Symptoms/etiology , Lower Urinary Tract Symptoms/therapy , Male , Prostate/blood supply , Prostate/surgery , Prostatic Hyperplasia/complications , Prostatic Hyperplasia/therapy , Transurethral Resection of Prostate/adverse effects , Transurethral Resection of Prostate/methods , Treatment Outcome
10.
Diagnostics (Basel) ; 11(11)2021 Nov 17.
Article in English | MEDLINE | ID: mdl-34829478

ABSTRACT

Abdominal aortic aneurysms (AAA) may remain clinically silent until they enlarge and patients present with a potentially lethal rupture. This necessitates early detection and elective treatment. The goal of this study was to develop an easy-to-train algorithm which is capable of automated AAA screening in CT scans and can be applied to an intra-hospital environment. Three deep convolutional neural networks (ResNet, VGG-16 and AlexNet) were adapted for 3D classification and applied to a dataset consisting of 187 heterogenous CT scans. The 3D ResNet outperformed both other networks. Across the five folds of the first training dataset it achieved an accuracy of 0.856 and an area under the curve (AUC) of 0.926. Subsequently, the algorithms performance was verified on a second data set containing 106 scans, where it ran fully automated and resulted in an accuracy of 0.953 and an AUC of 0.971. A layer-wise relevance propagation (LRP) made the decision process interpretable and showed that the network correctly focused on the aortic lumen. In conclusion, the deep learning-based screening proved to be robust and showed high performance even on a heterogeneous multi-center data set. Integration into hospital workflow and its effect on aneurysm management would be an exciting topic of future research.

11.
Cancers (Basel) ; 13(6)2021 Mar 18.
Article in English | MEDLINE | ID: mdl-33803522

ABSTRACT

Accurate detection of malignant transformation and risk-stratification of intraductal papillary mucinous neoplasms (IPMN) has remained a diagnostic challenge. Preliminary findings have indicated a promising role of positron emission tomography combined with computed tomography and 18F-fluorodeoxyglucose (18F-FDG-PET/CT) in detecting malignant IPMN. Therefore, the aim of this model-based economic evaluation was to analyze whether supplemental FDG-PET/CT could be cost-effective in patients with IPMN. Decision analysis and Markov modeling were applied to simulate patients' health states across a time frame of 15 years. CT/MRI based imaging was compared to a strategy with supplemental 18F-FDG-PET/CT. Cumulative costs in US-$ and outcomes in quality-adjusted life years (QALY) were computed based on input parameters extracted from recent literature. The stability of the model was evaluated by deterministic sensitivity analyses. In the base-case scenario, the CT/MRI-strategy resulted in cumulative discounted costs of USD $106,424 and 8.37 QALYs, while the strategy with supplemental FDG-PET/CT resulted in costs of USD $104,842 and a cumulative effectiveness of 8.48 QALYs and hence was cost-saving. A minimum specificity of FDG-PET/CT of 71.5% was required for the model to yield superior net monetary benefits compared to CT/MRI. This model-based economic evaluation indicates that supplemental 18F-FDG-PET/CT could have a favorable economic value in the management of IPMN and could be cost-saving in the chosen setting. Prospective studies with standardized protocols for FDG-PET/CT could help to better determine the value of FDG-PET/CT.

12.
Eur J Nucl Med Mol Imaging ; 48(10): 3268-3276, 2021 09.
Article in English | MEDLINE | ID: mdl-33686457

ABSTRACT

PURPOSE: Rectal cancer is one of the most frequent causes of cancer-related morbidity and mortality in the world. Correct identification of the TNM state in primary staging of rectal cancer has critical implications on patient management. Initial evaluations revealed a high sensitivity and specificity for whole-body PET/MRI in the detection of metastases allowing for metastasis-directed therapy regimens. Nevertheless, its cost-effectiveness compared with that of standard-of-care imaging (SCI) using pelvic MRI + chest and abdominopelvic CT is yet to be investigated. Therefore, the aim of this study was to analyze the cost-effectiveness of whole-body 18F FDG PET/MRI as an alternative imaging method to standard diagnostic workup for initial staging of rectal cancer. METHODS: For estimation of quality-adjusted life years (QALYs) and lifetime costs of diagnostic modalities, a decision model including whole-body 18F FDG PET/MRI with a hepatocyte-specific contrast agent and pelvic MRI + chest and abdominopelvic CT was created based on Markov simulations. For obtaining model input parameters, review of recent literature was performed. Willingness to pay (WTP) was set to $100,000/QALY. Deterministic sensitivity analysis of diagnostic parameters and costs was applied, and probabilistic sensitivity was determined using Monte Carlo modeling. RESULTS: In the base-case scenario, the strategy whole-body 18F FDG PET/MRI resulted in total costs of $52,186 whereas total costs of SCI were at $51,672. Whole-body 18F FDG PET/MRI resulted in an expected effectiveness of 3.542 QALYs versus 3.535 QALYs for SCI. This resulted in an incremental cost-effectiveness ratio of $70,291 per QALY for PET/MRI. Thus, from an economic point of view, whole-body 18F FDG PET/MRI was identified as an adequate diagnostic alternative to SCI with high robustness of results to variation of input parameters. CONCLUSION: Based on the results of the analysis, use of whole-body 18F FDG PET/MRI was identified as a feasible diagnostic strategy for initial staging of rectal cancer from a cost-effectiveness perspective.


Subject(s)
Fluorodeoxyglucose F18 , Rectal Neoplasms , Contrast Media , Cost-Benefit Analysis , Hepatocytes/pathology , Humans , Magnetic Resonance Imaging , Neoplasm Staging , Positron-Emission Tomography , Rectal Neoplasms/diagnostic imaging , Rectal Neoplasms/pathology , Sensitivity and Specificity , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...