1.
J Synchrotron Radiat ; 21(Pt 6): 1333-46, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25343803

ABSTRACT

A fast algorithm for ring artefact reduction in high-resolution micro-tomography with synchrotron radiation is presented. The new method is a generalization of the one proposed by Titarenko and collaborators, with a complete sinogram restoration prior to reconstruction with classical algorithms. The generalized algorithm can be performed in linear time and is easy to implement. Compared with the original approach, with an explicit solution, this approach is fast through the use of the conjugate gradient method. Also, low/high-resolution sinograms can be restored using higher/lower-order derivatives of the projections. Using different order for the derivative is an advantage over the classical Titarenko's approach. Several numerical results using the proposed method are provided, supporting our claims.

2.
Phys Med Biol ; 52(15): 4633-52, 2007 Aug 07.
Article in English | MEDLINE | ID: mdl-17634655

ABSTRACT

Cone-beam computed tomography (CBCT) enables three-dimensional imaging with isotropic resolution and a shorter acquisition time compared to a helical CT scanner. Because a larger object volume is exposed for each projection, scatter levels are much higher than in collimated fan-beam systems, resulting in cupping artifacts, streaks and quantification inaccuracies. In this paper, a general method to correct for scatter in CBCT, without supplementary on-line acquisition, is presented. This method is based on scatter calibration through off-line acquisition combined with on-line analytical transformation based on physical equations, to adapt calibration to the object observed. The method was tested on a PMMA phantom and on an anthropomorphic thorax phantom. The results were validated by comparison to simulation for the PMMA phantom and by comparison to scans obtained on a commercial multi-slice CT scanner for the thorax phantom. Finally, the improvements achieved with the new method were compared to those obtained using a standard beam-stop method. The new method provided results that closely agreed with the simulation and with the conventional CT scanner, eliminating cupping artifacts and significantly improving quantification. Compared to the beam-stop method, lower x-ray doses and shorter acquisition times were needed, both divided by a factor of 9 for the same scatter estimation accuracy.


Subject(s)
Algorithms , Artifacts , Imaging, Three-Dimensional/methods , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, Spiral Computed/methods , Pilot Projects , Reproducibility of Results , Scattering, Radiation , Sensitivity and Specificity