1.
Int J Bioprint ; 9(4): 727, 2023.
Article in English | MEDLINE | ID: mdl-37323487

ABSTRACT

Despite advances in prosthesis materials, operating microscopes and surgical techniques during the last 50 years, long-lasting hearing improvement remains a challenge in ossicular chain reconstruction. Failures in the reconstruction are mainly due to inadequate length or shape of the prosthesis, or defects in the surgical procedure. 3D-printed middle ear prosthesis might offer a solution to individualize treatment and obtain better results. The aim of the study was to study the possibilities and limitations of 3D-printed middle ear prostheses. Design of the 3D-printed prosthesis was inspired by a commercial titanium partial ossicular replacement prosthesis. 3D models of different lengths (1.5-3.0 mm) were created with Solidworks 2019-2021 software. The prostheses were 3D-printed with vat photopolymerization using liquid photopolymer Clear V4. Accuracy and reproducibility of 3D printing were evaluated with micro-CT imaging. The acoustical performance of the prostheses was determined in cadaver temporal bones with laser Doppler vibrometry. In this paper, we present an outline of individualized middle ear prosthesis manufacturing. 3D printing accuracy was excellent when comparing dimensions of the 3D-printed prostheses and their 3D models. Reproducibility of 3D printing was good if the diameter of the prosthesis shaft was 0.6 mm. 3D-printed partial ossicular replacement prostheses were easy to manipulate during surgery even though they were a bit stiffer and less flexible than conventional titanium prostheses. Their acoustical performance was similar to that of a commercial titanium partial ossicular replacement prosthesis. It is possible to 3D print functional individualized middle ear prostheses made of liquid photopolymer with good accuracy and reproducibility. These prostheses are currently suitable for otosurgical training. Further research is needed to explore their usability in a clinical setting. In the future, 3D printing of individualized middle ear prostheses may provide better audiological outcomes for patients.

2.
BMC Med Imaging ; 23(1): 51, 2023 04 10.
Article in English | MEDLINE | ID: mdl-37038130

ABSTRACT

BACKGROUND: Multi slice computed tomography (MSCT) is the most common used method in middle ear imaging. However, MSCT lacks the ability to distinguish the ossicular chain microstructures in detail resulting in poorer diagnostic outcomes. Novel cone beam computed tomography (CBCT) devices' image resolution is, on the other hand, better than MSCT resolution. The aim of this study was to optimize imaging parameters of a novel full body CBCT device to obtain optimal contrast to noise ratio (CNR) with low effective dose, and to optimize its clinical usability. METHODS: Imaging of five anonymous excised human cadaver temporal bones, the acquisition of the effective doses and the CNR measurements were performed for images acquired on using Planmed XFI® full body CBCT device (Planmed Oy, Helsinki, Finland) with a voxel size of 75 µm. All images acquired from the specimens using 10 different imaging protocols varying from their tube current exposure time product (mAs) and tube voltage (kVp) were analyzed for eight anatomical landmarks and evaluated by three evaluators. RESULTS: With the exception of protocol with 90 kVp 100 mAs, all other protocols used are competent to image the finest structures. With a moderate effective dose (86.5 µSv), protocol with 90 kV 450 mAs was chosen the best protocol used in this study. A significant correlation between CNR and clinical image quality of the protocols was observed in linear regression model. Using the optimized imaging parameters, we were able to distinguish even the most delicate middle ear structures in 2D images and produce accurate 3D reconstructions. CONCLUSIONS: In this ex vivo experiment, the new Planmed XFI® full body CBCT device produced excellent 2D resolution and easily created 3D reconstructions in middle ear imaging with moderate effective doses. This device would be suitable for middle ear diagnostics and for e.g., preoperative planning. Furthermore, the results of this study can be used to optimize the effective dose by selecting appropriate exposure parameters depending on the diagnostic task.


Subject(s)
Cone-Beam Computed Tomography , Tomography, X-Ray Computed , Humans , Radiation Dosage , Phantoms, Imaging , Cone-Beam Computed Tomography/methods , Tomography, X-Ray Computed/methods , Ear, Middle/diagnostic imaging
3.
Laryngoscope Investig Otolaryngol ; 6(5): 1158-1166, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34667861

ABSTRACT

OBJECTIVE: To describe the characteristics, diagnostics, treatment, and outcome of severe acute otitis media (AOM) and acute mastoiditis (AM) caused by group A beta-hemolytic streptococcus (GAS). STUDY DESIGN: A retrospective cohort study. METHODS: The yearly incidence of inpatient care-needing GAS AOM/AM patients in our hospital catchment area between 2002 and 2018 was investigated. A detailed analysis was performed for cases treated during the last GAS epidemic in 2017-2018. Anamnesis, signs and symptoms, pure-tone audiometry results, treatment, complications, and outcome were collected from medical charts. Patients responded to an otology-specific health-related quality of life survey (EOS-16) 1.5 to 3 years after their treatment. RESULTS: The number of GAS infections peaks at approximately 7-year intervals. During 2017 and 2018, altogether 37 patients (29 adults and 8 children) were hospitalized due to GAS AOM/AM. AM was diagnosed in 14 (38%) patients. The disease progression was typically very rapid. At presentation, all patients had severe ear pain, 68% tympanic membrane perforation and discharge, 43% fever, and 43% vertigo. In pure-tone audiometry, there was usually a marked mixed hearing loss at presentation. There was a significant recovery in both air and bone conduction thresholds; the pure tone average improvement from presentation was 32.3 ± 14.8 dB. Rapid strep tests (RST) proved to be more sensitive than bacterial culture in identifying GAS as a cause of AOM/AM. CONCLUSION: GAS AOM/AM has a rapid onset. Hearing loss usually includes a sensorineural component, which is usually reversible with adequate treatment. RST seems to be useful in detecting GAS from middle ear discharge. LEVEL OF EVIDENCE: 4.

4.
In Vivo ; 29(4): 487-91, 2015.
Article in English | MEDLINE | ID: mdl-26130793

ABSTRACT

BACKGROUND/AIM: The left atrium (LA) is frequently imaged in cardiac computed tomographic (cCT) examinations. The LA volume can be accurately measured with three-dimensional (3D) volumetry but this method is time consuming and thus not routinely used in clinical practice. Accordingly, increased LA size may be overlooked although volume enlargement is associated with adverse cardiovascular events. We evaluated the accuracy of LA diameter measurement in cCT and in transthoracic echocardiography (TTE) in the diagnosis of LA enlargement using 3D cCT as the reference standard. PATIENTS AND METHODS: Altogether, 146 patients with suspected cardiogenic stroke underwent cCT and TTE. LA volume by cCT was determined for all patients. LA diameter was measured in both modalities. Furthermore, 40 healthy controls were analyzed in order to assess the cut-off values for normal LA volume. Diagnostic performance of cCT and conventional TTE diametrical measurements for detecting enlarged LA volume were analyzed and compared using Cohen's kappa (κ). RESULTS: In controls, the mean LA volume was 59.8±15.3 ml and the mean LA diameter was 30.4±5.0 mm by cCT. The mean value plus twice the standard deviation, which was considered the upper limit, for normal LA volume and diameter were 90.4 ml and 40.4 mm, respectively. Age- and gender-matched patients with stroke had statistically significantly (p<0.001) larger LA volumes (85.5±21.1 vs. 59.8±15.3 ml) and diameters (37.6±5.7 vs. 30.4±5.0 mm) than controls. LA diameter measurement by cCT was more reliable in detecting an LA volume enlargement than the corresponding measurement with TTE (κ=0.489 vs. 0.234; p=0.002). CONCLUSION: An enlarged LA diameter measured by cCT was more reliable than TTE at detecting enlarged LA volume.


Subject(s)
Heart Atria/diagnostic imaging , Heart Atria/pathology , Tomography, X-Ray Computed , Aged , Case-Control Studies , Echocardiography , Female , Heart Diseases/diagnosis , Heart Diseases/etiology , Heart Diseases/pathology , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Reproducibility of Results , Retrospective Studies