Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
3.
A A Case Rep ; 7(9): 196-199, 2016 Nov 01.
Article in English | MEDLINE | ID: mdl-27607406

ABSTRACT

We describe the first case of a pregnant woman presenting with an acute inverted takotsubo-like cardiomyopathy caused by a postpartum diagnosed hemorrhagic pheochromocytoma, successfully treated with percutaneous venoarterial extracorporeal membrane oxygenation (va-ECMO). During admission, an emergency cesarean delivery had to be performed. The fetus needed resuscitation for 5 minutes. The mother was successfully resuscitated and treated with percutaneous va-ECMO for 7 days. Despite advances in diagnostic techniques during the past decade, in many cases, pheochromocytoma in pregnancy is still missed. This results in a maternal and fetal mortality rate of up to 30% in both.


Subject(s)
Adrenal Gland Neoplasms/therapy , Extracorporeal Membrane Oxygenation/methods , Hemorrhage/therapy , Pheochromocytoma/therapy , Pregnancy Complications, Cardiovascular/therapy , Pregnancy Complications, Neoplastic/therapy , Takotsubo Cardiomyopathy/therapy , Acute Disease , Adrenal Gland Neoplasms/complications , Adrenal Gland Neoplasms/diagnostic imaging , Adult , Female , Hemorrhage/complications , Hemorrhage/diagnostic imaging , Humans , Infant, Newborn , Pheochromocytoma/complications , Pheochromocytoma/diagnostic imaging , Pregnancy , Pregnancy Complications, Cardiovascular/diagnostic imaging , Pregnancy Complications, Cardiovascular/etiology , Pregnancy Complications, Neoplastic/diagnostic imaging , Takotsubo Cardiomyopathy/etiology , Treatment Outcome
4.
J Cardiothorac Vasc Anesth ; 22(2): 236-42, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18375326

ABSTRACT

OBJECTIVES: The aim of this study was to compare the following approaches to assess left ventricular preload by transesophageal echocardiography (TEE): left ventricular end-diastolic volume index (LVEDVI) determined by using the method of disc summation (LVEDVI(Md)) and left ventricular end-diastolic area index (LVEDAI) were compared with LVEDVI assessed by the modified Simpson formula (LVEDVI(Si)). Global end-diastolic volume index (GEDVI) and stroke volume index (SVI) measured by the PiCCO(plus) system (Pulsion Medical Systems, Munich, Germany) were used as TEE-independent reference variables. DESIGN: Prospective observational study. SETTING: Community hospital. PARTICIPANTS: Twenty-two patients undergoing elective cardiac surgery. INTERVENTIONS: After the induction of anesthesia, hemodynamic assessment by TEE and the PiCCO(plus) system was made 20 (T(1)) and 10 minutes (T(2)) before and 10 (T(3)) and 20 minutes (T(4)) after a fluid trial. At each time point, LVEDVI(Md), LVEDAI, LVEDVI(Si), GEDVI, and SVI were determined. MEASUREMENTS AND MAIN RESULTS: The fluid trial resulted in a significant increase of all preload variables measured at T(3). At T(4), all preload variables but LVEDVI(Md) showed a significant decrease. The mean bias +/- 2 SD for percent changes (Delta) of LVEDVI(Md) - DeltaLVEDVI(Si) was 1.5% +/- 59.0% and for DeltaLVEDAI - Delta LVEDVI(Si) 0.9% +/- 23.6%. The correlation between LVEDVI(Md) and LVEDVI(Si) was significantly weaker than between LVEDAI and LVEDVI(Si) (p < 0.001). Comparing TEE measurements with GEDVI and SVI, strong correlations were observed for LVEDAI and LVEDVI(Si) only. CONCLUSION: The method of disc summation cannot be recommended for preload assessment during a fluid challenge in cardiac surgery patients. By contrast, single-plane area measurements provided reliable information when compared with the application of the modified Simpson formula.


Subject(s)
Coronary Artery Bypass, Off-Pump/methods , Echocardiography, Transesophageal/methods , Ventricular Function, Left/physiology , Aged , Cardiac Output/physiology , Echocardiography, Transesophageal/instrumentation , Female , Humans , Male , Middle Aged , Prospective Studies , Sensitivity and Specificity , Stroke Volume/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...