1.
Otol Neurotol ; 43(3): 304-312, 2022 03 01.
Article in English | MEDLINE | ID: mdl-35061639

ABSTRACT

OBJECTIVE: To quantify the impact of cochlear implantation (CI) on all five vestibular end-organs and on subjective ratings of post-CI dizziness. METHODS: Seventy-two patients undergoing unilateral CI were recruited for the study. All participants completed pre- and post-CI three-dimensional video head-impulse tests (3D vHITs) to assess semicircular-canal (SC) function, air- and bone-conducted (AC and BC) cervical and ocular vestibular-evoked myogenic potentials (cVEMPs and oVEMPs) to assess otolith-function and the dizziness handicap inventory (DHI) to measure self-perceived disability. RESULTS: Nineteen percent of patients reported new or worsened dizziness postsurgery. Post-CI abnormalities (new lesions and significant deteriorations) were seen in the AC cVEMP (48%), AC oVEMP (34%), BC cVEMP (10%), and BC oVEMP (7%); and lateral (L) (17%), posterior (P) (10%), and anterior (A) (13%) SC vHITs. CI surgery was more likely to affect the AC cVEMP compared with the other tests (χ2 test, p < 0.05). Fifty percent of patients reported no dizziness pre- and postsurgery. In the implanted ear, normal pre-CI vHIT gain was preserved in lateral semicircular canal (LSC) (69%), anterior semicircular canal (ASC) (74%), and posterior semicircular canal (PSC) (67%), and normal reflex amplitudes were found in AC cVEMP (25%), AC oVEMP (20%), BC cVEMP (59%), and BC oVEMP (74%). Statistically significant decreases were observed in LSC vHIT gain, AC cVEMP amplitude, and AC oVEMP amplitude postsurgery (p < 0.05). There was a significant moderate positive correlation between change in DHI scores and the summed vestibular deficit postsurgery (r(51) = 0.38, p < 0.05). CONCLUSION: CI can impact tests that assess all five vestibular end-organs and subjective ratings of dizziness. These results support pre and post-surgical vestibular testing and assist preoperative counseling and candidate selection.


Subject(s)
Cochlear Implantation , Vestibular Evoked Myogenic Potentials , Dizziness/etiology , Head Impulse Test/methods , Humans , Otolithic Membrane , Vertigo , Vestibular Evoked Myogenic Potentials/physiology
2.
Front Neurol ; 11: 580184, 2020.
Article in English | MEDLINE | ID: mdl-33193031

ABSTRACT

Background: A sensitive test for Superior Semicircular Canal Dehiscence (SCD) is the air-conducted, ocular vestibular evoked myogenic potential (AC oVEMP). However, not all patients with large AC oVEMPs have SCD. This retrospective study sought to identify alternate diagnoses also producing enlarged AC oVEMPs and investigated bone-conducted (BC) oVEMP outcome measures that would help differentiate between these, and cases of SCD. Methods: We reviewed the clinical records and BC oVEMP results of 65 patients (86 ears) presenting with dizziness or balance problems who underwent CT imaging to investigate enlarged 105 dB nHL click AC oVEMP amplitudes. All patients were tested with BC oVEMPs using two different stimuli (1 ms square-wave pulse and 8 ms 125 Hz sine wave). Logistic regression and odds ratios were used to determine the efficacy of BC oVEMP amplitudes and latencies in differentiating between enlarged AC oVEMP amplitudes due to dehiscence from those with an alternate diagnosis. Results: Fifty-three ears (61.6%) with enlarged AC oVEMP amplitudes were identified as having frank dehiscence on imaging; 33 (38.4%) had alternate diagnoses that included thinning of the bone covering (near dehiscence, n = 13), vestibular migraine (n = 12 ears of 10 patients), enlarged vestibular aqueduct syndrome (n = 2) and other causes of recurrent episodic vertigo (n = 6). BC oVEMP amplitudes of dehiscent and non-dehiscent ears were not significantly different (p > 0.05); distributions of both groups overlapped with the range of healthy controls. There were significant differences in BC oVEMP latencies between dehiscent and non-dehiscent ears for both stimuli (p < 0.001). A prolonged n1 125 Hz latency (>11.5 ms) was the best predictor of dehiscence (odd ratio = 27.8; 95% CI:7.0-111.4); abnormal n1 latencies were identified in 79.2% of ears with dehiscence compared with 9.1% of ears without dehiscence. Conclusions: A two-step protocol of click AC oVEMP amplitudes and 125 Hz BC oVEMP latency measures optimizes the specificity of VEMP testing in SCD.

SELECTION OF CITATIONS
SEARCH DETAIL
...