1.
Int J Mol Sci ; 25(10)2024 May 07.
Article in English | MEDLINE | ID: mdl-38791113

ABSTRACT

Since the establishment of regulations for exposure to extremely low-frequency (0-300) Hz electromagnetic fields, scientific opinion has prioritised the hypothesis that the most important parameter determining cellular behaviour has been intensity, ignoring the other exposure parameters (frequency, time, mode, waveform). This has been reflected in the methodologies of the in vitro articles published and the reviews in which they are included. A scope review was carried out, grouping a total of 79 articles that met the proposed inclusion criteria and studying the effects of the different experiments on viability, proliferation, apoptosis, oxidative stress and the cell cycle. These results have been divided and classified by frequency, intensity, exposure time and exposure mode (continuous/intermittent). The results obtained for each of the processes according to the exposure parameter used are shown graphically to highlight the importance of a good methodology in experimental development and the search for mechanisms of action that explain the experimental results, considering not only the criterion of intensity. The consequence of this is a more than necessary revision of current exposure protection regulations for the general population based on the reductionist criterion of intensity.


Subject(s)
Apoptosis , Electromagnetic Fields , Oxidative Stress , Humans , Electromagnetic Fields/adverse effects , Oxidative Stress/radiation effects , Animals , Apoptosis/radiation effects , Cell Cycle/radiation effects , Cell Survival/radiation effects , Cell Proliferation/radiation effects
2.
Front Bioeng Biotechnol ; 12: 1337899, 2024.
Article in English | MEDLINE | ID: mdl-38524191

ABSTRACT

In vitro studies requiring controlled exposure to low-frequency electromagnetic fields employ exposure systems with different geometries and configurations, the Helmholtz configuration being one of the most widely used. This configuration has limitations in the homogeneity of the spatial distribution of the magnetic field intensity values. We present the design, manufacturing, and characterisation of a new coil system, called RILZ configuration, which improves the distribution of magnetic field intensity values in the three dimensions of space for three different heights in comparison with the traditional circular coils in Helmholtz configuration. In addition, a comparative study of the cellular response in CT2A cultures exposed to a magnetic field of 50 Hz and 100 µT for 48 hrs is performed with both exposure systems. The results of the study show reduced values of deviation from the central value of magnetic field intensity using the RILZ coil system. These differences are statistically significant compared to the Helmholtz configuration for the three Cartesian directions: x (p < 0.01), y (p < 0.01), z (p < 0.01). In addition, the intensity values for three different heights are statistically significantly correlated using the RILZ coil system (p < 0.01). The differences in cell behaviour are also statistically significant between the two systems (p < 0.01) and may be directly related to the differences found in the distribution of intensity values between the two systems. This study highlights the importance of the homogeneity of the magnetic field intensity generated by the exposure systems used and offers an effective solution to control the magnetic field exposure parameters in vitro assays.

3.
Sensors (Basel) ; 21(21)2021 Nov 07.
Article in English | MEDLINE | ID: mdl-34770707

ABSTRACT

A novel compact device with spectrum analyzer characteristics has been designed, which allows the measuring of the maximum power received in multiple narrow frequency bands of 300 kHz, recording the entire spectrum from 78 MHz to 6 GHz; the device is capable of measuring the entire communications spectrum and detecting multiple sources of electromagnetic fields using the same communications band. The proposed device permits the evaluation of the cross-talk effect that, in conventional exposimeters, generates a mistake estimation of electromagnetic fields. The device was calibrated in an anechoic chamber for far-fields and was validated against a portable spectrum analyzer in a residential area. A strong correlation between the two devices with a confidence higher than 95% was obtained; indicating that the device could be considered as an important tool for electromagnetic field studies.

4.
Sensors (Basel) ; 21(8)2021 Apr 13.
Article in English | MEDLINE | ID: mdl-33924605

ABSTRACT

Viscosity variation in human fluids, such as Synovial Fluid (SF) or Cerebrospinal Fluid (CSF), can be used as a diagnostic factor; however, the sample volume obtained for analysis is usually small, making it difficult to measure its viscosity. On the other hand, Quartz Crystal Resonators (QCR) have been used widely in sensing applications due to their accuracy, cost, and size. This work provides the design and validation of a new viscosity measurement system based on quartz crystal resonators for low volume fluids, leading to the development of a sensor called "ViSQCT" as a prototype for a new medical diagnostic tool. The proposed method is based on measuring the resonance frequency at the crystal's maximum conductance point through a frequency sweep, where crystals with 10 MHz fundamental resonance frequency were used. For validation purposes, artificial fluids were developed to simulate SFs and CFs in healthy and pathological conditions as experiment phantoms. A commercial QCR based system was also used for validation since its methodology differs from ours. A conventional rotational viscometer was used as a reference for calibration purposes. ViSQCT demonstrates the capability to measure the sample's viscosity differentiation between healthy and pathological fluid phantoms and shows that it can be used as a basis for a diagnostic method of several pathologies related to the studied biological fluids. However, some performance differences between both QCR-based systems compared to the reference system deserves further investigation.


Subject(s)
Quartz , Synovial Fluid , Humans , Viscosity