Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 9(3): 1860-75, 2009.
Article in English | MEDLINE | ID: mdl-22573991

ABSTRACT

Two novel polymeric membrane sensors for the analysis of Pb(II) have been developed based on two therapeutic drugs, thiopental (TP) and phenytoin (PT) as two new ionophores and potassium tetrakis(p-chlorophenyl) borate (KTpClPB) as a lipophilic additive, in plasticized PVC membranes. The sensors show a Nernstian response for Pb(II) ions over the wide concentration ranges of 1×10(-2) - 7×10(-6) M and 1×10(-2) - 8×10(-6) M for the sensors based on thiopental and phenytoin, respectively. The proposed sensors have a fast response time and can be used for more than nine weeks without any considerable divergence in potentials. The sensors exhibit comparatively good selectivity with respect to alkaline, alkaline earth and some transition and heavy metal ions. They were employed for direct determination of lead in solder alloys and in galena rocks with a good agreement with the obtained results by atomic absorption spectroscopy.

2.
Anal Sci ; 21(2): 107-10, 2005 Feb.
Article in English | MEDLINE | ID: mdl-15732467

ABSTRACT

Novel miniaturized polyurethane (PU) membrane sensors in an all-solid state graphite support were developed, electrochemically evaluated and used for the assay of thiopental drug. The thiopental (T) sensors are based on the formation of ion-association complexes of thiopental with copper(II) and cobalt(II)-bathophenanthroline (bphen) counter anions as electroactive materials dispersed in a polyurethane matrix. The sensors show a linear response for thiopental over the range of 1 x 10(-1) - 5 x 10(-5) M thiopental at 25 degrees C over the pH range 6 - 11 with anionic slopes of -28.7 and -28.3 mV decade(-1) with Cu- and Co-bphen thiopental membrane sensors, respectively. These sensors exhibit a fast response time (25 - 45 s), a low detection limit (5 x 10(-6) M), a long lifetime (7 weeks) and good stability. The selectivity coefficients for thiopental sensors relative to the number of interfering anions, were investigated. These sensors were used for the direct potentiometry of thiopental in a pharmaceutical formulation and human serum. Results with mean accuracy of 99.8 +/- 0.5% of nominal were obtained, which compare well with data obtained using spectrophotometric (UV-Vis) and British Pharmacopoeia (BP) methods.


Subject(s)
Hypnotics and Sedatives/analysis , Hypnotics and Sedatives/chemistry , Thiopental/analysis , Thiopental/chemistry , Humans , Hypnotics and Sedatives/blood , Membranes, Artificial , Miniaturization , Molecular Structure , Potentiometry , Sensitivity and Specificity , Thiopental/blood
SELECTION OF CITATIONS
SEARCH DETAIL
...