1.
Heart Rhythm ; 2024 May 19.
Article in English | MEDLINE | ID: mdl-38768839

ABSTRACT

BACKGROUND: The safety and long-term efficacy of radiofrequency (RF) catheter ablation (CA) of paroxysmal atrial fibrillation (PAF) has been well established. Contemporary techniques to optimize ablation delivery, reduce fluoroscopy use, and improve clinical outcomes have been developed. OBJECTIVE: The purpose of this study was to assess the contemporary real-world practice approach and long-term outcomes of RF CA for PAF through a prospective multicenter registry. METHODS: Using the REAL-AF (Real-world Experience of Catheter Ablation for the Treatment of Symptomatic Paroxysmal and Persistent Atrial Fibrillation; ClincalTrials.gov Identifier: NCT04088071) Registry, patients undergoing RF CA to treat PAF across 42 high-volume institutions and 79 experienced operators were evaluated. The procedures were performed using zero or reduced fluoroscopy, contact force sensing catheters, wide area circumferential ablation, and ablation index as a guide with a target of 380-420 for posterior and 500-550 for anterior lesions. The primary efficacy outcome was freedom from all-atrial arrhythmia recurrence at 12 months. RESULTS: A total of 2470 patients undergoing CA from January 2018 to December 2022 were included. Mean age was 65.2 ±11.14 years, and 44% were female. Most procedures were performed without fluoroscopy (71.5%), with average procedural and total RF times of 95.4 ± 41.7 minutes and 22.1±11.8 minutes, respectively. At 1-year follow-up, freedom from all-atrial arrhythmias was 81.6% with 89.7% of these patients off antiarrhythmic drugs. No significant difference was identified comparing pulmonary vein isolation vs pulmonary vein isolation + ablation approaches. The complication rate was 1.9%. CONCLUSION: Refinement of RF CA to treat PAF using contemporary tools, standardized protocols, and electrophysiology laboratory workflows resulted in excellent short- and long-term clinical outcomes.

2.
J Vis Exp ; (206)2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38709062

ABSTRACT

Radiofrequency (RF) ablation to perform pulmonary vein isolation (PVI) for the treatment of atrial fibrillation involves some risk to collateral structures, including the esophagus. Proactive esophageal cooling using a dedicated device has been granted marketing authorization by the Food and Drug Administration (FDA) to reduce the risk of ablation-related esophageal injury due to RF cardiac ablation procedures, and more recent data also suggest that esophageal cooling may contribute to improved long-term efficacy of treatment. A mechanistic underpinning explaining these findings exists through the quantification of lesion placement contiguity defined as the Continuity Index (CI). Kautzner et al. quantified the CI by the order of lesion placement, such that whenever a lesion is placed non-adjacent to the prior lesion, the CI is incremented by the number of segments the catheter tip has moved over. To facilitate real-time calculation of the CI and encourage further adoption of this instrument, we propose a modification in which the placement of non-adjacent lesions increments the CI by only one unit, avoiding the need to count potentially nebulous markers of atrial segmentation. The objective of this protocol is to describe the methods of calculating the CI both prospectively during real-time PVI cases and retrospectively using recorded case data. A comparison of the results obtained between cases that utilized proactive esophageal cooling and cases that used luminal esophageal temperature (LET) monitoring is then provided.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophagus , Atrial Fibrillation/surgery , Esophagus/surgery , Humans , Catheter Ablation/methods , Catheter Ablation/instrumentation , Pulmonary Veins/surgery
3.
medRxiv ; 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38645228

ABSTRACT

Background: Proactive esophageal cooling is FDA cleared to reduce the likelihood of esophageal injury during radiofrequency ablation for treatment of atrial fibrillation (AF). Long-term follow-up data have also shown improved freedom from arrhythmia with proactive esophageal cooling compared to luminal esophageal temperature (LET) monitoring during pulmonary vein isolation (PVI). One hypothesized mechanism is improved lesion contiguity (as measured by the Continuity Index) with the use of cooling. We aimed to compare the Continuity Index of PVI cases using proactive esophageal cooling to those using LET monitoring. Methods: Continuity Index was calculated for PVI cases at two different hospitals within the same health system using a slightly modified Continuity Index to facilitate both real-time calculation during observation of PVI cases and retrospective determination from recorded cases. The results were then compared between proactively cooled cases and those using LET monitoring. Results: Continuity Indices for a total of 101 cases were obtained; 77 cases using proactive esophageal cooling and 24 cases using traditional LET monitoring. With proactive esophageal cooling, the average Continuity Index was 2.7 (1.3 on the left pulmonary vein, and 1.5 on the right pulmonary vein). With LET monitoring, the average Continuity Index was 27.3 (14.3 on the left, and 12.9 on the right), for a difference of 24.6 (p < 0.001). Conclusion: Proactive esophageal cooling during PVI is associated with significantly improved lesion contiguity when compared to LET monitoring. This finding may offer a mechanism for the greater freedom from arrhythmia seen with proactive cooling in long-term follow-up.

4.
JACC Clin Electrophysiol ; 9(12): 2558-2570, 2023 12.
Article in English | MEDLINE | ID: mdl-37737773

ABSTRACT

BACKGROUND: Active esophageal cooling reduces the incidence of endoscopically identified severe esophageal lesions during radiofrequency (RF) catheter ablation of the left atrium for the treatment of atrial fibrillation. A formal analysis of the atrioesophageal fistula (AEF) rate with active esophageal cooling has not previously been performed. OBJECTIVES: The authors aimed to compare AEF rates before and after the adoption of active esophageal cooling. METHODS: This institutional review board (IRB)-approved study was a prospective analysis of retrospective data, designed before collecting and analyzing the real-world data. The number of AEFs occurring in equivalent time frames before and after adoption of cooling using a dedicated esophageal cooling device (ensoETM, Attune Medical) were quantified across 25 prespecified hospital systems. AEF rates were then compared using generalized estimating equations robust to cluster correlation. RESULTS: A total of 14,224 patients received active esophageal cooling during RF ablation across the 25 hospital systems, which included a total of 30 separate hospitals. In the time frames before adoption of active cooling, a total of 10,962 patients received primarily luminal esophageal temperature (LET) monitoring during their RF ablations. In the preadoption cohort, a total of 16 AEFs occurred, for an AEF rate of 0.146%, in line with other published estimates for procedures using LET monitoring. In the postadoption cohort, no AEFs were found in the prespecified sites, yielding an AEF rate of 0% (P < 0.0001). CONCLUSIONS: Adoption of active esophageal cooling during RF ablation of the left atrium for the treatment of atrial fibrillation was associated with a significant reduction in AEF rate.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophageal Fistula , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Retrospective Studies , Esophageal Fistula/epidemiology , Esophageal Fistula/etiology , Catheter Ablation/methods
5.
J Interv Card Electrophysiol ; 65(3): 617-623, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35416632

ABSTRACT

BACKGROUND: Active esophageal cooling is increasingly utilized as an alternative to luminal esophageal temperature (LET) monitoring for protection against thermal injury during pulmonary vein isolation (PVI) when treating atrial fibrillation (AF). Published data demonstrate the efficacy of active cooling in reducing thermal injury, but impacts on procedural efficiency are not as well characterized. LET monitoring compels pauses in ablation due to heat stacking and temperature overheating alarms that in turn delay progress of the PVI procedure, whereas active esophageal cooling allows avoidance of this phenomenon. Our objective was to measure the change in PVI procedure duration after implementation of active esophageal cooling as a protective measure against esophageal injury. METHODS: We performed a retrospective review under IRB approval of patients with AF undergoing PVI between January 2018 and February 2020. For each patient, we recorded age, gender, and total procedure time. We then compared procedure times before and after the implementation of active esophageal cooling as a replacement for LET monitoring. RESULTS: A total of 373 patients received PVI over the study period. LET monitoring using a multi-sensor probe was performed in 198 patients, and active esophageal cooling using a dedicated device was performed in 175 patients. Patient characteristics did not significantly differ between groups (mean age of 67 years, and gender 37.4% female). Mean procedure time was 146 ± 51 min in the LET-monitored patients, and 110 ± 39 min in the actively cooled patients, representing a reduction of 36 min, or 24.7% of total procedure time (p < .001). Median procedure time was 141 [IQR 104 to 174] min in the LET-monitored patients and 100 [IQR 84 to 122] min in the actively cooled patients, for a reduction of 41 min, or 29.1% of total procedure time (p < .001). CONCLUSIONS: Implementation of active esophageal cooling for protection against esophageal injury during PVI was associated with a significantly large reduction in procedure duration.


Subject(s)
Hypothermia, Induced , Pulmonary Veins , Aged , Female , Humans , Male , Pulmonary Veins/surgery , Esophagus
6.
J Interv Card Electrophysiol ; 62(3): 487-494, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34212280

ABSTRACT

PURPOSE: Catheter ablation has become a mainstay therapy for atrial fibrillation (AF) with rapid innovation over the past decade. Variability in ablation techniques may impact efficiency, safety, and efficacy; and the ideal strategy is unknown. Real-world evidence assessing the impact of procedural variations across multiple operators may provide insight into these questions. The Real-world Experience of Catheter Ablation for the Treatment of Symptomatic Paroxysmal (PAF) and Persistent (PsAF) Atrial Fibrillation registry (Real-AF) is a multicenter prospective registry that will enroll patients at high volume centers, including academic institutions and private practices, with operators performing ablations primarily with low fluoroscopy when possible. The study will also evaluate the contribution of advent in technologies and workflows to real-world clinical outcomes. METHODS: Patients presenting at participating centers are screened for enrollment. Data are collected at the time of procedure, 10-12 weeks, and 12 months post procedure and include patient and detailed procedural characteristics, with short and long-term outcomes. Arrhythmia recurrences are monitored through standard of care practice which includes continuous rhythm monitoring at 6 and 12 months, event monitors as needed for routine care or symptoms suggestive of recurrence, EKG performed at every visit, and interrogation of implanted device or ILR when applicable. RESULTS: Enrollment began in January 2018 with a single site. Additional sites began enrollment in October 2019. Through May 2021, 1,243 patients underwent 1,269 procedures at 13 institutions. Our goal is to enroll 4000 patients. DISCUSSION: Real-AF's multiple data sources and detailed procedural information, emphasis on high volume operators, inclusion of low fluoroscopy operators, and use of rigorous standardized follow-up methodology allow systematic documentation of clinical outcomes associated with changes in ablation workflow and technologies over time. Timely data sharing may enable real-time quality improvements in patient care and delivery. Trial registration Clinicaltrials.gov: NCT04088071 (registration date: September 12, 2019).


Subject(s)
Atrial Fibrillation , Catheter Ablation , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Humans , Prospective Studies , Recurrence , Registries , Treatment Outcome
SELECTION OF CITATIONS