1.
J Appl Clin Med Phys ; : e14438, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38889325

ABSTRACT

BACKGROUND: Novel on-board CBCT allows for improved image quality and Hounsfield unit accuracy. When coupled with online adaptive tools, this may have potential to allow for simulation and treatment to be completed in a single on-table session. PURPOSE: To study the feasibility of a high-efficiency radiotherapy treatment workflow without the use of a separate session for simulation imaging. The dosimetric accuracy, overall efficiency, and technical feasibility were used to evaluate the clinical potential of CT simulation-free adaptive radiotherapy. METHODS: Varian's Ethos adaptive radiotherapy treatment platform was upgraded with a novel CBCT system, HyperSight which reports image quality and Hounsfield unit accuracy specifications comparable to standard fan-beam CT. Using in-house developed MATLAB software, CBCT images were imported into the system and used for planning. Two test cases were completed on anthropomorphic phantoms equipped with small volume ion chambers (cross-calibrated to an ADCL traceable dose standard) to evaluate the feasibility and accuracy of the workflows. A simulated palliative spine treatment was planned with 8 Gy in one fraction, and an intact prostate treatment was planned with 60 Gy in 20 fractions. The CBCTs were acquired using HyperSight with default thorax and pelvis imaging protocols and reconstructed using an iterative algorithm with scatter removal, iCBCT Acuros. CBCTs were used for contouring and planning, and treatment was delivered via an online adaptive workflow. In addition, an external dosimetry audit was completed using only on-board CBCT imaging in an end-to-end head and neck phantom irradiation. RESULTS: An extended-field CBCT acquisition can be acquired in 12 s, in addition to the time for longitudinal table shifts, and reconstructed in approximately 1 min. The superior-inferior extent for the CBCT planning images was 38.2 cm, which captured the full extent of relevant anatomy. The contouring and treatment planning for the spine and prostate were completed in 30 and 18 min, respectively. The dosimetric agreement between ion chamber measurements and the treatment plan was within a range of -1.4 to 1.6%, and a mean and standard deviation of 0.41 ± 1.16%. All metrics used in the external audit met the passing criteria, and the dosimetric comparison between fan-beam and CBCT techniques had a gamma passing rate of 99.0% with a criteria of 2%/2 mm. CONCLUSION: Using an in-house workflow, CT simulation-free radiation therapy was shown to be feasible with acceptable workflow efficiency and dosimetric accuracy. This approach may be particularly applicable for urgent palliative treatments. With the availability of software to enable this workflow, and the continued advancement of on-treatment adaptation, single-visit radiation therapy may replace current practice for some clinical indications.

2.
Int J Radiat Oncol Biol Phys ; 118(3): 839-852, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-37778424

ABSTRACT

PURPOSE: Approximately 90% of patients undergoing breast cancer radiation therapy experience skin toxicities that are difficult to classify and predict ahead of time. A prediction of toxicity at the early stages of the treatment would provide clinicians with a prompt to intervene. The objectives of this study were to evaluate the correlation between skin toxicity and radiomic features extracted from optical and infrared (thermal) images of skin, and to develop a model for predicting a patient's skin response to radiation. METHODS AND MATERIALS: Optical and infrared breast and chest-wall images were acquired daily during the course of radiation therapy, as well as weekly for 3 weeks after the end of treatment for 20 patients with breast cancer. Skin-toxicity assessments were conducted weekly until the patients' final visit. Skin color and temperature trends from histogram-based and texture-based radiomic features, extracted from the treatment area, were analyzed, reduced, and used in a cross-validation machine learning model to predict the patients' skin toxicity grades. RESULTS: A set of 9 independent color and temperature features with significant correlation to skin toxicity were identified from 108 features. The cross-validation accuracy of a cubic Support Vector Machine remained >85% and area under the receiver operating characteristic curve remained >0.75, when reducing the input imaging data to include only the sessions with a biologically effective dose not exceeding 30 Gy (approximately the first third to first half of the total treatment dose). CONCLUSIONS: The quantitative analysis of radiomic features extracted from optical and infrared (thermal) images of skin was shown to be promising for predicting skin toxicities.


Subject(s)
Breast Neoplasms , Radiomics , Humans , Female , Prospective Studies , Breast , Machine Learning , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/radiotherapy , Retrospective Studies
3.
Pract Radiat Oncol ; 2023 Nov 07.
Article in English | MEDLINE | ID: mdl-37939844

ABSTRACT

PURPOSE: The goal of this study was to evaluate the image quality provided by a novel cone beam computed tomography (CBCT) platform (HyperSight, Varian Medical Systems), a platform with enhanced reconstruction algorithms as well as rapid acquisition times. Image quality was compared with both status quo CBCT for image guidance, and to fan beam CT (FBCT) acquired on a CT simulator (CTsim). METHODS AND MATERIALS: In a clinical study, 30 individuals were recruited for whom either deep inspiration (DIBH) or deep exhalation breath hold (DEBH) was used during imaging and radiation treatment of tumors involving liver, lung, breast, abdomen, chest wall, and pancreatic sites. All subjects were imaged during breath hold with CBCT on a standard image guidance platform (TrueBeam 2.7, Varian Medical Systems) and FBCT CT (CTsim, GE Optima). HyperSight imaging with both breath hold (HSBH) and free breathing (HSFB) was performed in a single session. The 4 image sets thus acquired were registered and compared using metrics quantifying artifact index, image nonuniformity, contrast, contrast-to-noise ratio, and difference of Hounsfield unit (HU) from CTsim. RESULTS: HSBH provided less severe artifacts compared with both HSFB and TrueBeam. The severity of artifacts in HSBH images was similar to that in CTsim images, with statistically similar artifact index values. CTsim provided the best image uniformity; however, HSBH provided improved uniformity compared with both HSFB and TrueBeam. CTsim demonstrated elevated contrast compared with HyperSight imaging, but both HSBH and HSFB imaging showed superior contrast-to-noise ratio characteristics compared with TrueBeam. The median HU difference of HSBH from CTsim was within 1 HU for muscle/fat tissue, 12 HU for bone, and 14 HU for lung. CONCLUSIONS: The HyperSight system provides 6-second CBCT acquisition with image artifacts that are significantly reduced compared with TrueBeam and comparable to those in CTsim FBCT imaging. HyperSight breath hold imaging was of higher quality compared with free breathing imaging on the same system. The median HU value in HyperSight breath hold imaging is within 15 HU of that in CTsim imaging for muscle, fat, bone, and lung tissue types, indicating the utility of image data for direct dose calculation in adaptive workflows.

4.
Med Phys ; 50(3): 1824-1842, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36546558

ABSTRACT

PURPOSE AND OBJECTIVE: To describe a methodology for the dual-material fused deposition modeling (FDM) 3D printing of plastic scintillator arrays, to characterize their light output under irradiation using an sCMOS camera, and to establish a methodology for the dosimetric calibration of planar array geometries. MATERIALS AND METHODS: We have published an investigation into the fabrication and characterization of single element FDM printed scintillators intending to produce customizable dosimeters for radiation therapy applications. 1 This work builds on previous investigations by extending the concept to the production of a high-resolution (scintillating element size 3 × 3 × 3 mm3 ) planar scintillator array. The array was fabricated using a BCN3D Epsilon W27 3D printer and composed of polylactic acid (PLA) filament and BCF-10 plastic scintillator. The array's response was initially characterized using a 20 × 20 cm2 6 MV photon field with a source-to-surface (SSD) distance of 100 cm and the beam incident on the top of the array. The light signals emitted under irradiation were imaged using 200 ms exposures from a sCMOS camera positioned at the foot of the treatment couch (210 cm from the array). The collected images were then processed using a purpose-built software to correct known optical artefacts and determine the light output for each scintillating element. The light output was then corrected for element sensitivity and calibrated to dose using Monte Carlo simulations of the array and irradiation geometry based on the array's digital 3D print model. To assess the accuracy of the array calibration both a 3D beam and a clinical VMAT plan were delivered. Dose measurements using the calibrated array were then compared to EBT3 GAFChromic film and OSLD measurements, as well as Monte Carlo simulations and TPS calculations. RESULTS: Our results establish the feasibility of dual-material 3D printing for the fabrication of custom plastic scintillator arrays. Assessment of the 3D printed scintillators response across each row of the array demonstrated a nonuniform response with an average percentage deviation from the mean of 2.1% ± 2.8%. This remains consistent with our previous work on individual 3D printed scintillators which showed an average difference of 2.3% and a maximum of 4.0% between identically printed scintillators.1 Array dose measurements performed following calibration indicate difficulty in differentiating the scintillator response from ambient background light contamination at low doses (<20-25 cGy) and dose rates (≤100 MU/min). However, when analysis was restricted to exclude dose values less than 10% of the Monte Carlo simulated max dose the average absolute percentage dose difference between Monte Carlo simulation and array measurement was 5.3% ± 4.8% for the fixed beam delivery and 5.4% ± 5.2% for the VMAT delivery CONCLUSION: In this study, we developed and characterized a 3D printed array of plastic scintillators and demonstrated a methodology for the dosimetric calibration of a simple array geometry.


Subject(s)
Radiometry , Software , Radiometry/methods , Radiotherapy Dosage , Plastics , Printing, Three-Dimensional , Monte Carlo Method
5.
J Appl Clin Med Phys ; 24(2): e13814, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36286619

ABSTRACT

PURPOSE: To investigate the feasibility of cardiac synchronized gating in stereotactic body radiation therapy (SBRT) of ventricular tachycardia (VT) using a real-time electrocardiogram (ECG) signal acquisition. METHODS AND MATERIALS: Stability of beam characteristics during simulated ECG gating was examined by developing a microcontroller interface to a Varian Clinac iX linear accelerator allowing gating at frequencies and duty cycles relevant to cardiac rhythm. Delivery accuracy was evaluated by measuring dose linearity with an ionization chamber, and flatness and symmetry with a two-dimensional detector array, for different gating windows within typical human cardiac cycle periods. To establish a practical method of gating based on actual ECG signals, an AD8232 Heart Monitor board was used to acquire the ECG signal and synchronize the beam delivery. Real-time cardiac gated delivery measurements were performed for a single 10 × 10 cm2 field and for a VT-SBRT plan using intensity-modulated radiation therapy (IMRT). RESULTS AND DISCUSSION: Dose per monitor unit (MU) values were found to be linear within most gating windows investigated with maximum differences relative to non-gated delivery of <2% for gating windows ≥200 ms and for >10 MUs. Beam profiles for both gated and non-gated modes were also found to agree with maximum differences of 0.5% relative to central axis dose for all sets of beam-on/beam-off combinations. Comparison of dose distributions for intensity-modulated SBRT plans between non-gating and cardiac gating modes provided a gamma passing rate of 97.2% for a 2% 2 mm tolerance. CONCLUSIONS: Beam output is stable with respect to linearity, flatness, and symmetry for gating windows within cardiac cycle periods. Agreement between dose distributions for VT-SBRT using IMRT in non-gated and cardiac cycle gated delivery modes shows that the proposed methodology is feasible. Technically, gating for delivery of SBRT for VT is possible with regard to beam stability.


Subject(s)
Radiosurgery , Radiotherapy, Intensity-Modulated , Tachycardia, Ventricular , Humans , Radiosurgery/methods , Radiotherapy Dosage , Feasibility Studies , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Electrocardiography , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/radiotherapy , Tachycardia, Ventricular/surgery
6.
Med Phys ; 49(12): 7661-7671, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36106659

ABSTRACT

PURPOSE: Over the past decades, continuous efforts have been made to improve megavoltage (MV) image quality versus dose characteristics, including the implementation of low atomic number (Z) targets in MV beamlines and the development of more efficient detectors. Recently, a diamond target beam within a commercial radiotherapy treatment platform demonstrated improved planar contrast-to-noise-ratio (CNR) per unit dose using a novel 2.5 MV sintered diamond target beam, which enabled image acquisition on the order of mGy. The present work assesses cone beam CT (CBCT) image quality characteristics for the novel 2.5 MV diamond target beam and the effects of volume-of-interest (VOI) collimation on the image quality and imaging dose distribution. METHODS: A sintered diamond target was incorporated into the target arm of the linear accelerator, replacing the 2.5 MV commercial copper imaging target. CBCT image quality was evaluated against the commercial imaging beam with regard to spatial resolution and CNR versus dose. In addition to full-field acquisitions, we investigated VOI techniques that collimate the imaging beam to preselected anatomy, to determine potential image quality improvements and dose sparing capacity. Using an anthropomorphic phantom, VOI regions were defined to encompass the maxillary and ethmoid sinuses and ranged in dimension from 3 cm to 4.85 cm equivalent radius. The MLC was fit to each VOI structure throughout a full CBCT arc and the corresponding MLC sequences were produced as XML scripts for acquisition. Calibrated radiochromic film was used in phantom to measure cumulative axial dose distributions during each CBCT acquisition. RESULTS: In full-field CBCT, the 2.5 MV diamond target beam demonstrated improved CNR versus dose compared to the commercial imaging beam, by factors of up to 1.7. The calculated modulation transfer function (MTF) displayed an increase of nearly 30% in f50 for the 2.5 MV diamond target beam compared to the commercial beam. Using VOI techniques, CNR increased monotonically as a function of equivalent radius at the bone-tissue interface. At the bone-sinus interface, the CNR for the full-field case was slightly decreased compared to the largest VOI case. Imaging dose in the anteroposterior direction increased with increasing VOI equivalent radius. CONCLUSION: The novel 2.5 MV sintered diamond target beam presents a simple modification to the commercial imaging beam which provides improved image quality in full-field CBCT and the potential for simultaneous dose sparing and CNR improvement at high-contrast interfaces using VOI acquisition techniques.


Subject(s)
Cone-Beam Computed Tomography , Diamond , Cone-Beam Computed Tomography/methods , Phantoms, Imaging , Particle Accelerators , Synchrotrons
7.
J Appl Clin Med Phys ; 23(11): e13773, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36052990

ABSTRACT

PURPOSE: Thermoplastic immobilizers are used routinely in radiation therapy to achieve positioning accuracy. These devices are variable in quality as they are dependent on the skill of the human fabricator. We examine the potential multi jet fusion (MJF) 3D printing for the production immobilizers with a focus on the surface dosimetry of several MJF-printed PA12-based material candidates. Materials are compared with the goal of minimizing surface dose with comparison to standard thermoplastic. We introduce a novel metamaterial design for the shell of the immobilizer, with the aims of mechanical robustness and low-dose buildup. We demonstrate first examples of adult and pediatric cranial and head-and-neck immobilizers. METHODS: Three different PA12 materials were examined and compared to fused deposition modeling-printed polylactic acid (PLA), PLA with density lowered by adding hollow glass microspheres, and to perforated or perforated/stretched and solid status quo thermoplastic samples. Build-up dose measurements were made using a parallel plate chamber. A metamaterial design was established based on a packed hexagonal geometry. Radiochromic film dosimetry was performed to determine the dependence of surface dose on the metamaterial design. Full cranial and head-and-neck prototype immobilizers were designed, printed, and assessed with regard to dimensional accuracy. RESULTS: Build-up dose measurements demonstrated the superiority of the PA12 material with a light fusing agent, which yielded a ∼15% dose reduction compared to other MJF materials. Metamaterial samples provided dose reductions ranging from 11% to 40% compared to stretched thermoplastic. MJF-printed immobilizers were produced reliably, demonstrated the versatility of digital design, and showed dimensional accuracy with 97% of sampled points within ±2 mm. CONCLUSIONS: MJF is a promising technology for an automated fabrication of patient immobilizers. Material selection and metamaterial design can be leveraged to yield surface dose reduction of up to 40%. Immobilizer design is highly customizable, and the first examples of MJF-printed immobilizers demonstrate excellent dimensional accuracy.


Subject(s)
Polyesters , Printing, Three-Dimensional , Adult , Humans , Child , Film Dosimetry , Radiometry
8.
J Appl Clin Med Phys ; 23(12): e13777, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36125203

ABSTRACT

Entry into the field of clinical medical physics is most commonly accomplished through the completion of a Commission on Accreditation of Medical Physics Educational Programs (CAMPEP)-accredited graduate and residency program. To allow a mechanism to bring valuable expertise from other disciplines into clinical practice in medical physics, an "alternative pathway" approach was also established. To ensure those trainees who have completed a doctoral degree in physics or a related discipline have the appropriate background and didactic training in medical physics, certificate programs and a CAMPEP-accreditation process for these programs were initiated. However, medical physics-specific didactic, research, and clinical exposure of those entering medical physics residencies from these certificate programs is often comparatively modest when evaluated against individuals holding Master's and/or Doctoral degrees in CAMPEP-accredited graduate programs. In 2016, the AAPM approved the formation of Task Group (TG) 298, "Alternative Pathway Candidate Education and Training." The TG was charged with reviewing previous published recommendations for alternative pathway candidates and developing recommendations on the appropriate education and training of these candidates. This manuscript is a summary of the AAPM TG 298 report.


Subject(s)
Education, Medical , Internship and Residency , Radiation Oncology , Humans , Health Physics/education , Clinical Competence , Education, Medical, Graduate
9.
Sci Rep ; 12(1): 1559, 2022 01 28.
Article in English | MEDLINE | ID: mdl-35091583

ABSTRACT

Radiotherapy (RT) is an effective cancer treatment modality, but standard RT often causes collateral damage to nearby healthy tissues. To increase therapeutic ratio, radiosensitization via gold nanoparticles (GNPs) has been shown to be effective. One challenge is that megavoltage beams generated by clinical linear accelerators are poor initiators of the photoelectric effect. Previous computer models predicted that a diamond target beam (DTB) will yield 400% more low-energy photons, increasing the probability of interacting with GNPs to enhance the radiation dose by 7.7-fold in the GNP vicinity. After testing DTB radiation coupled with GNPs in multiple cell types, we demonstrate decreased head-and-neck cancer (HNC) cell viability in vitro and enhanced cell-killing in zebrafish xenografts compared to standard RT. HNC cell lines also displayed increased double-stranded DNA breaks with DTB irradiation in the presence of GNPs. This study presents preclinical responses to GNP-enhanced radiotherapy with the novel DTB, providing the first functional data to support the theoretical evidence for radiosensitization via GNPs in this context, and highlighting the potential of this approach to optimize the efficacy of RT in anatomically difficult-to-treat tumors.


Subject(s)
Gold
10.
J Appl Clin Med Phys ; 22(12): 72-86, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34679247

ABSTRACT

PURPOSE: To investigate the possible advantages of using 4pi-optimized arc trajectories in stereotactic body radiation therapy of ventricular tachycardia (VT-SBRT) to minimize exposure of healthy tissues. METHODS AND MATERIALS: Thorax computed tomography (CT) data for 15 patients were used for contouring organs at risk (OARs) and defining realistic planning target volumes (PTVs). A conventional trajectory plan, defined as two full coplanar arcs was compared to an optimized-trajectory plan provided by a 4pi algorithm that penalizes geometric overlap of PTV and OARs in the beam's-eye-view. A single fraction of 25 Gy was prescribed to the PTV in both plans and a comparison of dose sparing to OARs was performed based on comparisons of maximum, mean, and median dose. RESULTS: A significant average reduction in maximum dose was observed for esophagus (18%), spinal cord (26%), and trachea (22%) when using 4pi-optimized trajectories. Mean doses were also found to decrease for esophagus (19%), spinal cord (33%), skin (18%), liver (59%), lungs (19%), trachea (43%), aorta (11%), inferior vena cava (25%), superior vena cava (33%), and pulmonary trunk (26%). A median dose reduction was observed for esophagus (40%), spinal cord (48%), skin (36%), liver (72%), lungs (41%), stomach (45%), trachea (53%), aorta (45%), superior vena cava (38%), pulmonary veins (32%), and pulmonary trunk (39%). No significant difference was observed for maximum dose (p = 0.650) and homogeneity index (p = 0.156) for the PTV. Average values of conformity number were 0.86 ± 0.05 and 0.77 ± 0.09 for the conventional and 4pi optimized plans respectively. CONCLUSIONS: 4pi optimized trajectories provided significant reduction to mean and median doses to cardiac structures close to the target but did not decrease maximum dose. Significant improvement in maximum, mean and median doses for noncardiac OARs makes 4pi optimized trajectories a suitable delivery technique for treating VT.


Subject(s)
Radiosurgery , Radiotherapy, Intensity-Modulated , Tachycardia, Ventricular , Humans , Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Vena Cava, Superior
11.
Phys Med Biol ; 66(23)2021 11 22.
Article in English | MEDLINE | ID: mdl-34710856

ABSTRACT

Brachytherapy is a mature treatment modality. The literature is abundant in terms of review articles and comprehensive books on the latest established as well as evolving clinical practices. The intent of this article is to part ways and look beyond the current state-of-the-art and review emerging technologies that are noteworthy and perhaps may drive the future innovations in the field. There are plenty of candidate topics that deserve a deeper look, of course, but with practical limits in this communicative platform, we explore four topics that perhaps is worthwhile to review in detail at this time. First, intensity modulated brachytherapy (IMBT) is reviewed. The IMBT takes advantage ofanisotropicradiation profile generated through intelligent high-density shielding designs incorporated onto sources and applicators such to achieve high quality plans. Second, emerging applications of 3D printing (i.e. additive manufacturing) in brachytherapy are reviewed. With the advent of 3D printing, interest in this technology in brachytherapy has been immense and translation swift due to their potential to tailor applicators and treatments customizable to each individual patient. This is followed by, in third, innovations in treatment planning concerning catheter placement and dwell times where new modelling approaches, solution algorithms, and technological advances are reviewed. And, fourth and lastly, applications of a new machine learning technique, called deep learning, which has the potential to improve and automate all aspects of brachytherapy workflow, are reviewed. We do not expect that all ideas and innovations reviewed in this article will ultimately reach clinic but, nonetheless, this review provides a decent glimpse of what is to come. It would be exciting to monitor as IMBT, 3D printing, novel optimization algorithms, and deep learning technologies evolve over time and translate into pilot testing and sensibly phased clinical trials, and ultimately make a difference for cancer patients. Today's fancy is tomorrow's reality. The future is bright for brachytherapy.


Subject(s)
Brachytherapy , Neoplasms , Algorithms , Brachytherapy/methods , Humans , Neoplasms/radiotherapy , Printing, Three-Dimensional , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods
12.
Med Phys ; 48(7): 4053-4063, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33880777

ABSTRACT

PURPOSE: The purpose of this study is to improve dose distribution and organ-at-risk sparing during gynecologic HDR brachytherapy with patient-specific applicators. The majority of applicators used today are generic in design and do not allow for dose modulation for patient-specific shaping of dose distributions. Their performance might be adjusted with commercially available wedge shields; however, this provides dose modulation in the orthogonal plane only and does not allow for variation along the length of the applicator. Generic applicators are available only in standard sizes and geometries, and provide suboptimal patient fit with limited dose modulation. METHODS: In this paper we use Monte Carlo modeling for comprehensive characterization of radiologic properties of various 3D printable biocompatible and sterilizable materials with comparison to water. Based on these results, we choose the optimal set of materials for a patient-specific applicator. We develop a novel method to design the patient-specific applicator without incurring a significant increase in treatment time or changes to clinical workflow. Finally, using an example of two selected vaginal cancers, we compare the performance of patient-specific and water-equivalent applicators in terms of target coverage and rectum sparing. RESULTS: In the energy range from 1 MeV to 4 MeV, all materials have similar attenuation coefficients. In the range from ~2 keV to 1 MeV and above 4 MeV, tungsten-polylactic acid composite (WPLA) was seen to have the highest attenuation coefficient. The dose distribution of the water-equivalent applicator was found to be symmetric about its central axis. At the same time patient-specific shielded applicators exhibit well-modulated dose distributions. Their isodose lines are seen to spread radially into the patient, while merging close to the applicator surface, where WPLA shielding has been applied. CONCLUSIONS: The patient-specific cylinders provide comparable dose to the target, while offering advanced healthy tissue sparing, not achievable with the generic design.


Subject(s)
Brachytherapy , Female , Humans , Iridium Radioisotopes , Monte Carlo Method , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
13.
J Appl Clin Med Phys ; 21(9): 16-24, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32643322

ABSTRACT

This work introduces a novel capacitive-sensing technology capable of detecting respiratory motion with high temporal frequency (200 Hz). The system does not require contact with the patient and has the capacity to sense motion through clothing or plastic immobilization devices. ABSTRACT: PURPOSE: This work presents and evaluates a novel capacitive monitoring system (CMS) technology for continuous detection of respiratory motion during radiation therapy. This modular system provides real-time motion monitoring without any contact with the patient, ionizing radiation, or surrogates such as reflective markers on the skin. MATERIALS AND METHODS: The novel prototype features an array of capacitive detectors that are sensitive to the position of the body and capable of high temporal frequency readout. Performance of this system was investigated in comparison to the RPM infrared (IR) monitoring system (Varian Medical Systems). The prototype included three (5 cm × 10 cm) capacitive copper sensors in one plane, located at a distance of 8-10 cm from the volunteer. Capacitive measurements were acquired for central and lateral-to-central locations during chest free-breathing and abdominal breathing. The RPM IR data were acquired with the reflector block at corresponding positions simultaneously. The system was also tested during deep inspiration and expiration breath-hold maneuvers. RESULTS: Capacitive monitoring system data demonstrate close agreement with the RPM status quo at all locations examined. Cross-correlation analysis on RPM and CMS data showed an average absolute lag of 0.07 s (range: 0.03-0.23 s) for DIBH and DEBH data and 0.15 s (range: 0-0.43 s) for free-breathing. Amplitude difference between the normalized CMS and RPM signal during chest and abdominal breathing was within 0.15 for 94.3% of the data points after synchronization. CMS performance was not affected when the subject was clothed. CONCLUSION: This novel technology permits sensing of both free-breathing and breath-hold respiratory motion. It provides data comparable to the RPM system but without the need for an IR tracking camera in the treatment room or use of reflective markers on the patient.


Subject(s)
Breath Holding , Respiration , Exhalation , Humans , Motion
14.
J Appl Clin Med Phys ; 21(8): 15-26, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32459059

ABSTRACT

PURPOSE/OBJECTIVES: Three-dimensional (3D) printing is recognized as an effective clinical and educational tool in procedurally intensive specialties. However, it has a nascent role in radiation oncology. The goal of this investigation is to clarify the extent to which 3D printing applications are currently being used in radiation oncology through a systematic review of the literature. MATERIALS/METHODS: A search protocol was defined according to preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines. Included articles were evaluated using parameters of interest including: year and country of publication, experimental design, sample size for clinical studies, radiation oncology topic, reported outcomes, and implementation barriers or safety concerns. RESULTS: One hundred and three publications from 2012 to 2019 met inclusion criteria. The most commonly described 3D printing applications included quality assurance phantoms (26%), brachytherapy applicators (20%), bolus (17%), preclinical animal irradiation (10%), compensators (7%), and immobilization devices (5%). Most studies were preclinical feasibility studies (63%), with few clinical investigations such as case reports or series (13%) or cohort studies (11%). The most common applications evaluated within clinical settings included brachytherapy applicators (44%) and bolus (28%). Sample sizes for clinical investigations were small (median 10, range 1-42). A minority of articles described basic or translational research (11%) and workflow or cost evaluation studies (3%). The number of articles increased over time (P < 0.0001). While outcomes were heterogeneous, most studies reported successful implementation of accurate and cost-effective 3D printing methods. CONCLUSIONS: Three-dimensional printing is rapidly growing in radiation oncology and has been implemented effectively in a diverse array of applications. Although the number of 3D printing publications has steadily risen, the majority of current reports are preclinical in nature and the few clinical studies that do exist report on small sample sizes. Further dissemination of ongoing investigations describing the clinical application of developed 3D printing technologies in larger cohorts is warranted.


Subject(s)
Brachytherapy , Radiation Oncology , Animals , Phantoms, Imaging , Printing, Three-Dimensional
15.
Phys Med Biol ; 65(8): 085001, 2020 04 17.
Article in English | MEDLINE | ID: mdl-32126542

ABSTRACT

Brachytherapy accelerated partial breast irradiation (APBI) is well tolerated, but reported acute toxicities including moist desquamation rates range from 7% to 39%. Moist desquamation is correlated to long-term skin toxicity and high skin dose is the main risk factor. This study uses radiochromic films for in vivo skin dosimetry of low dose rate (LDR) APBI brachytherapy and prediction of skin toxicity. Patients participating in a clinical trial assessing skin toxicity of LDR seed brachytherapy were included in this study. Following the seed implantation procedure, patients were asked to wear a customized oval shaped radiochromic film on the skin projection of the planned target volume (PTV) for 24 h. Exposed films were collected, and maximum point doses were measured. In addition, maximum doses to a small skin volume (D0.2cc) were calculated on the pre- and post-implant CT-scan. Acute skin toxicities (redness, pigmentation, induration and dermatitis) were scored by the treating physician for 2 months during follow-up visits. Skin dose measurements and acute toxicity were available for 18 consecutive patients. The post-implant calculated maximum skin doses (D0.2cc), 60.8 Gy (SD ± 41.0), were on average 30% higher than those measured in vivo (Dmax-film), 46.6 Gy (SD ± 19.3), but those values were highly significantly correlated (Spearman's rho 0.827, p < 0.001). Also, dermatitis and induration were significantly correlated with higher in vivo measured and post-implant calculated skin dose. Pre-implant dosimetry was not correlated with measured or post-implant skin dose or side effects. Radiochromic films can reliably diagnose excess dose to the skin during the first 24 h and predict skin toxicity, which enables preventative measures. Trial registration: Nederlands Trial Register (www.trialregister.nl), NTR6549, the trial was registered prospectively on 27 June 2017. ABR number: NL56210.078.16.


Subject(s)
Brachytherapy/adverse effects , Breast Neoplasms/radiotherapy , Film Dosimetry , Skin/radiation effects , Adult , Female , Humans , Middle Aged , Radiotherapy Dosage , Risk Assessment
16.
Biomed Phys Eng Express ; 6(5): 055014, 2020 09 08.
Article in English | MEDLINE | ID: mdl-33444245

ABSTRACT

We propose a new methodology for the fabrication and evaluation of scintillating detector elements using a consumer grade fusion deposition modeling (FDM) 3D printer. In this study we performed a comprehensive investigation into both the effects of the 3D printing process on the scintillation light output of 3D printed plastic scintillation dosimeters (PSDs) and their associated dosimetric properties. Fabrication properties including print variability, layer thickness, anisotropy and extrusion temperature were assessed for 1 cm3 printed samples. We then examined the stability, dose linearity, dose rate proportionality, energy dependence and reproducibility of the 3D printed PSDs compared to benchmarks set by commercially available products. Experimental results indicate that the shape of the emission spectrum of the 3D printed PSDs do not show significant spectral differences when compared to the emission spectrum of the commercial sample. However, the magnitude of scintillation light output was found to be strongly dependent on the parameters of the fabrication process. Dosimetric testing indicates that the 3D printed PSDs share many desirable properties with current commercially available PSDs such as dose linearity, dose rate independence, energy independence in the MV range, repeatability, and stability. These results demonstrate that not only does 3D printing offer a new avenue for the production and manufacturing of PSDs but also allows for further investigation into the application of 3D printing in dosimetry. Such investigations could include options for 3D printed, patient-specific scintillating dosimeters that may be used as standalone dosimeters or incorporated into existing 3D printed patient devices (e.g. bolus or immobilization) used during the delivery of radiation therapy.


Subject(s)
Plastics/chemistry , Printing, Three-Dimensional/instrumentation , Radiation Dosimeters/statistics & numerical data , Scintillation Counting/instrumentation , Humans
17.
Phys Imaging Radiat Oncol ; 16: 103-108, 2020 Oct.
Article in English | MEDLINE | ID: mdl-33458352

ABSTRACT

BACKGROUND AND PURPOSE: A commercial 2.5 MV beam has been clinically available for beam's-eye-view imaging in radiotherapy, offering improved contrast-to-noise ratio (CNR) compared to therapeutic beams, due to the softer spectrum. Previous research suggested that imaging performance could be improved using a low-Z diamond target to reduce the self-absorption of diagnostic energy photons. The aim of this study was to 1) investigate the feasibility of two 2.5 MV diamond target beamline configurations and 2) characterize the dosimetry and planar image quality of these novel low-Z beams. MATERIALS AND METHODS: The commercial 2.5 MV beam was modified by replacing the copper target with sintered diamond. Two beamlines were investigated: a carousel-mounted diamond target beamline and a 'conventional' beamline, with the diamond target in the target arm. Planar image quality was assessed in terms of spatial resolution and CNR. RESULTS: Due to image artifacts, image quality could not be assessed for the carousel-mounted low-Z target beam. The 'conventional' 2.5 MV low-Z beam quality was softer by 2.7% compared to the commercial imaging beam, resulting in improved CNR by factors of up to 1.3 and 1.7 in thin and thick phantoms, respectively. In regard to spatial resolution, the 'conventional' 2.5 MV low-Z beam slightly outperformed the commercial imaging beam. CONCLUSION: With a simple modification to the 2.5 MV commercial beamline, we produced an improved energy spectrum for imaging. This 2.5 MV diamond target beam proved to be an advantageous alternative to the commercial target configuration, offering both superior resolution and CNR.

18.
Med Phys ; 46(3): 1175-1181, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30624784

ABSTRACT

PURPOSE: To evaluate possible use for cone-beam computed tomography (CBCT) guidance, this phantom study evaluated the contrast enhancement provided by Gadoxetate Disodium (Primovist® CAN/EU, or Eovist® USA, Bayer Healthcare, Leverkusen, Germany), a contrast agent that is taken up selectively by liver cells and is retained for up to an hour. Image quality from CBCT was benchmarked against helical fan-beam computed tomography for two phantom geometries. METHODS AND MATERIALS: Concentrations were diluted to 0.0125-0.1 mmol per kilogram of body weight (mmol/kg) corresponding to expected physiological concentrations in the liver. Kilovoltage CBCT imaging parameters of x-ray tube potential, current, and filtration were investigated using clinically available options on a TrueBeam STx linear accelerator CBCT platform. Two phantoms were created, a cylindrical idealized imaging geometry and an ellipsoidal more realistic abdominal geometry. All parameters were optimized according to the contrast-to-noise ratio (CNR) image quality metric, as a function of concentration, following the Rose criterion for CNR. RESULTS: Acceptable CNR was defined as greater than or equal to three, in accordance with the Rose criterion for CNR. These were found in a range of expected liver concentrations of 0.025-0.1 mmol/kg for a tube potential of 100 kVp, half-fan bowtie filtration and tube currents giving exposures between 2025 and 5085 mAs. Linear correlations were found for all CNR as a function of concentration, in agreement with the literature. CONCLUSION: Based on this phantom study, with appropriate selection of imaging protocol, Gadoxetate Disodium may provide useful liver CBCT enhancement at physiologically achievable liver concentrations.


Subject(s)
Cone-Beam Computed Tomography/methods , Contrast Media , Liver Neoplasms/diagnostic imaging , Phantoms, Imaging , Radiographic Image Enhancement/methods , Radiosurgery/methods , Surgery, Computer-Assisted/methods , Algorithms , Humans , Image Processing, Computer-Assisted/methods , Liver Neoplasms/surgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods
19.
Biomed Phys Eng Express ; 6(1): 015013, 2019 12 19.
Article in English | MEDLINE | ID: mdl-33438601

ABSTRACT

The purpose of this investigation is to improve intra-fractional motion detection during cranial stereotactic radiosurgery with a novel capacitive motion sensing (CMS) system. Previous work showed that a capacitive detection system, based on a MPR121 capacitance-to-digital converter, provided a number of advantages over existing patient imaging systems used in the clinic, by uniquely offering ionizing-radiation-free and continuous monitoring without modification to the immobilization mask or treatment room. However, in order to provide submillimeter detection accuracy, the MPR121-based CMS system required relatively large sensors in close proximity to the patient. Therefore, the aim of this investigation was to improve sensitivity of the system, allowing reduction in sensor size and preserving its stable operation in the linear accelerator environment. For this, we developed, characterized and compared motion detection capabilities of four CMS systems based on different capacitance-to-digital converters: MPR121, CPT212B, FDC1004 and FDC2214. Among all candidates, the FDC2214-based system was found to uniquely combine accurate 3D motion detection in real time, with stable performance under ionizing radiation. It exhibited an order of magnitude improvement in sensitivity in comparison with the proof-of-study system, allowing a spatial precision as low as 0.3 mm, and its overall performance was found to satisfy the AAPM practice guidelines of positioning tolerance within 1 mm. Furthermore, the high sensitivity of the system allows both reduction of the sensor area and location more distant from the patient surface, which are key improvements with regard to development of a clinical device.


Subject(s)
Motion , Radiosurgery/methods , Computer Systems , Cone-Beam Computed Tomography , Electric Capacitance , Humans , Immobilization , Particle Accelerators , Phantoms, Imaging , Radiation, Ionizing , Radiotherapy Planning, Computer-Assisted , Reproducibility of Results
20.
Pract Radiat Oncol ; 8(4): 221-229, 2018.
Article in English | MEDLINE | ID: mdl-29452866

ABSTRACT

PURPOSE: This patient study evaluated the use of 3-dimensional (3D) printed bolus for chest wall radiation therapy compared with standard sheet bolus with regard to accuracy of fit, surface dose measured in vivo, and efficiency of patient setup. By alternating bolus type over the course of therapy, each patient served as her own control. METHODS AND MATERIALS: For 16 patients undergoing chest wall radiation therapy, a custom 5.0 mm thick bolus was designed based on the treatment planning computed tomography scan and 3D printed using polylactic acid. Cone beam computed tomography scanning was used to image and quantify the accuracy of fit of the 2 bolus types with regard to air gaps between the bolus and skin. As a quality assurance measure for the 3D printed bolus, optically stimulated luminescent dosimetry provided in vivo comparison of surface dose at 7 points on the chest wall. Durations of patient setup and image guidance were recorded and compared. RESULTS: In 13 of 16 patients, the bolus was printed without user intervention, and the median print time was 12.6 hours. The accuracy of fit of the bolus to the chest wall was improved significantly relative to standard sheet bolus, with the frequency of air gaps 5 mm or greater reduced from 30% to 13% (P < .001) and maximum air gap dimension diminished from 0.5 ± 0.3 to 0.3 ± 0.3 mm on average. Surface dose was within 3% for both standard sheet and 3D printed bolus. On average, the use of 3D printed bolus reduced the setup time from 104 to 76 seconds. CONCLUSIONS: This study demonstrates 3D printed bolus in postmastectomy radiation therapy improves fit of the bolus and reduces patient setup time marginally compared with standard vinyl gel sheet bolus. The time savings on patient setup must be weighed against the considerable time needed for the 3D printing process.


Subject(s)
Breast Neoplasms/radiotherapy , Printing, Three-Dimensional , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy/methods , Adult , Aged , Aged, 80 and over , Breast Neoplasms/surgery , Equipment Design , Female , Humans , Mastectomy , Middle Aged , Radiotherapy/instrumentation , Radiotherapy Dosage , Thoracic Wall/radiation effects , Tomography, X-Ray Computed