Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
1.
J Nucl Med ; 2024 May 09.
Article in English | MEDLINE | ID: mdl-38724275

ABSTRACT

Currently, cutoffs of quantitative [15O]H2O PET to detect fractional flow reserve (FFR)-defined coronary artery disease (CAD) were derived from a single cohort that included patients without prior CAD. However, prior CAD, sex, and age can influence myocardial blood flow (MBF). Therefore, the present study determined the influence of prior CAD, sex, and age on optimal cutoffs of hyperemic MBF (hMBF) and coronary flow reserve (CFR) and evaluated whether cutoff optimization enhanced diagnostic performance of quantitative [15O]H2O PET against an FFR reference standard. Methods: Patients with chronic coronary symptoms underwent [15O]H2O PET and invasive coronary angiography with FFR. Optimal cutoffs for patients with and without prior CAD and subpopulations based on sex and age were determined. Results: This multicenter study included 560 patients. Optimal cutoffs were similar for patients with (n = 186) and without prior CAD (hMBF, 2.3 vs. 2.3 mL·min-1·g-1; CFR, 2.7 vs. 2.6). Females (n = 190) had higher hMBF cutoffs than males (2.8 vs. 2.3 mL·min-1·g-1), whereas CFRs were comparable (2.6 vs. 2.7). However, female sex-specific hMBF cutoff implementation decreased diagnostic accuracy as compared with the cutoff of 2.3 mL·min-1·g-1 (72% vs. 82%, P < 0.001). Patients aged more than 70 y (n = 79) had lower hMBF (1.7 mL·min-1·g-1) and CFR (2.3) cutoffs than did patients aged 50 y or less, 51-60 y, and 61-70 y (hMBF, 2.3-2.4 mL·min-1·g-1; CFR, 2.7). Age-specific cutoffs in patients aged more than 70 y yielded comparable accuracy to the previously established cutoffs (hMBF, 72% vs. 76%, P = 0.664; CFR, 80% vs. 75%, P = 0.289). Conclusion: Patients with and without prior CAD had similar [15O]H2O PET cutoffs for detecting FFR-defined significant CAD. Stratifying patients according to sex and age led to different optimal cutoffs; however, these values did not translate into an increased overall accuracy as compared with previously established thresholds for MBF.

2.
Pacing Clin Electrophysiol ; 47(1): 121-123, 2024 01.
Article in English | MEDLINE | ID: mdl-38055567

ABSTRACT

Cardiac resynchronization therapy (CRT) is an established treatment for heart failure patients with left ventricular dysfunction and a left bundle branch block. However, its impact on right ventricular (RV) function remains uncertain. This cardiac magnetic resonance imaging study found that CRT did not improve RV volumes and function, and CRT-off during follow-up had an immediate detrimental effect on the RV, which may suggest potential unfavorable RV remodeling with RV pacing during CRT.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Cardiac Resynchronization Therapy/methods , Bundle-Branch Block/therapy , Heart Ventricles/diagnostic imaging , Treatment Outcome , Heart Failure/therapy , Ventricular Function, Left , Electrocardiography/methods
3.
Eur Heart J Cardiovasc Imaging ; 25(3): 347-355, 2024 Feb 22.
Article in English | MEDLINE | ID: mdl-37812691

ABSTRACT

AIMS: We examined the association between the symptom-to-reperfusion-time and cardiovascular magnetic resonance (CMR)-derived global strain parameters and transmural infarct extent in ST-segment elevation myocardial infarction (STEMI) patients. METHODS AND RESULTS: The study included 108 STEMI patients who underwent successful primary percutaneous coronary intervention (PPCI). Patients were categorized according to the median symptom-to-reperfusion-time: shorter (<160 min, n = 54) and longer times (>160 min, n = 54). CMR was performed 2-7 days after PPCI and at 1 month. CMR cine imaging was performed for functional assessment and late gadolinium enhancement to evaluate transmural infarct extent. Myocardial feature-tracking was used for strain analysis. Groups were comparable in relation to incidence of LAD disease and pre- and post-PPCI thrombolysis in myocardial infarction (TIMI) flow grades. The mean transmural extent score at follow-up was lower in patients with shorter reperfusion time (P < 0.01). Both baseline and follow-up maximum transmural extent scores were smaller in patients with shorter reperfusion time (P = 0.03 for both). Patients with shorter reperfusion time had more favourable global left ventricular (LV) circumferential strain (baseline, P = 0.049; follow-up, P = 0.01) and radial strain (baseline, P = 0.047; follow-up, P < 0.01), whilst LV longitudinal strain appeared comparable for both baseline and follow-up (P > 0.05 for both). In multi-variable regression analysis including all three strain directions, baseline LV circumferential strain was independently associated with the mean transmural extent score at follow-up (ß=1.89, P < 0.001). CONCLUSION: In STEMI patients, time-to-reperfusion was significantly associated with smaller transmural extent of infarction and better LV circumferential and radial strain. Moreover, infarct transmurality and residual LV circumferential strain are closely linked.


Subject(s)
ST Elevation Myocardial Infarction , Humans , ST Elevation Myocardial Infarction/diagnostic imaging , ST Elevation Myocardial Infarction/therapy , ST Elevation Myocardial Infarction/complications , Contrast Media , Gadolinium , Heart , Reperfusion
5.
Eur Heart J Cardiovasc Imaging ; 25(1): 116-126, 2023 Dec 21.
Article in English | MEDLINE | ID: mdl-37578007

ABSTRACT

AIMS: In chronic coronary syndrome (CCS) patients with documented coronary artery disease (CAD), ischaemia detection by myocardial perfusion imaging (MPI) and an invasive approach are viable diagnostic strategies. We compared the diagnostic performance of quantitative flow ratio (QFR) with single-photon emission computed tomography (SPECT), positron emission tomography (PET), and cardiac magnetic resonance imaging (CMR) in patients with prior CAD [previous percutaneous coronary intervention (PCI) and/or myocardial infarction (MI)]. METHODS AND RESULTS: This PACIFIC-2 sub-study evaluated 189 CCS patients with prior CAD for inclusion. Patients underwent SPECT, PET, and CMR followed by invasive coronary angiography with fractional flow reserve (FFR) measurements of all major coronary arteries (N = 567), except for vessels with a sub-total or chronic total occlusion. Quantitative flow ratio computation was attempted in 488 (86%) vessels with measured FFR available (FFR ≤0.80 defined haemodynamically significant CAD). Quantitative flow ratio analysis was successful in 334 (68%) vessels among 166 patients and demonstrated a higher accuracy (84%) and sensitivity (72%) compared with SPECT (66%, P < 0.001 and 46%, P = 0.001), PET (65%, P < 0.001 and 58%, P = 0.032), and CMR (72%, P < 0.001 and 33%, P < 0.001). The specificity of QFR (87%) was similar to that of CMR (83%, P = 0.123) but higher than that of SPECT (71%, P < 0.001) and PET (67%, P < 0.001). Lastly, QFR exhibited a higher area under the receiver operating characteristic curve (0.89) than SPECT (0.57, P < 0.001), PET (0.66, P < 0.001), and CMR (0.60, P < 0.001). CONCLUSION: QFR correlated better with FFR in patients with prior CAD than MPI, as reflected in the higher diagnostic performance measures for detecting FFR-defined, vessel-specific, significant CAD.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Myocardial Perfusion Imaging , Percutaneous Coronary Intervention , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Angiography/methods , Myocardial Perfusion Imaging/methods , Predictive Value of Tests
7.
J Am Heart Assoc ; 12(15): e028014, 2023 08.
Article in English | MEDLINE | ID: mdl-37489727

ABSTRACT

Background Among patients with an implantable cardioverter-defibrillator, a high prevalence of atrial fibrillation (AF) is present. Identification of AF predictors in this patient group is of clinical importance to initiate appropriate preventive therapeutic measures to reduce the risk of AF-related complications. This study assesses whether cardiac magnetic resonance imaging-derived atrial characteristics are associated with AF development in patients with a dual-chamber implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator, as detected by the cardiac implantable electronic device. Methods and Results This single-center retrospective study included 233 patients without documented AF history at the moment of device implantation (dual-chamber implantable cardioverter-defibrillator [63.5%] or cardiac resynchronization therapy defibrillator [36.5%]). All patients underwent cardiac magnetic resonance imaging before device implantation. Cardiac magnetic resonance-derived features of left atrial (LA) remodeling were evaluated in all patients. Detection of AF episodes was based on cardiac implantable electronic device interrogation. During a median follow-up of 6.1 years, a newly diagnosed AF episode was detected in 88 of the 233 (37.8%) patients with an ICD. In these patients, increased LA volumes and impaired LA function (LA emptying fraction and LA strain) were found as compared with patients without AF during follow-up. However, a significant association was only found in patients with dilated cardiomyopathy and not in patients with ischemic cardiomyopathy. Conclusions LA remodeling characteristics were associated with development of AF in patients with dilated cardiomyopathy but not patients with ischemic cardiomyopathy, suggesting different mechanisms of AF development in ischemic cardiomyopathy and dilated cardiomyopathy. Assessment of LA remodeling before device implantation might identify high-risk patients for AF.


Subject(s)
Atrial Fibrillation , Cardiomyopathy, Dilated , Defibrillators, Implantable , Myocardial Ischemia , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Defibrillators, Implantable/adverse effects , Retrospective Studies , Cardiomyopathy, Dilated/etiology , Myocardial Ischemia/etiology , Magnetic Resonance Imaging
8.
J Clin Med ; 12(12)2023 Jun 12.
Article in English | MEDLINE | ID: mdl-37373691

ABSTRACT

OBJECTIVES: This prospective pilot study assessed the feasibility of cardiovascular magnetic resonance (CMR) imaging during biventricular (BIV) pacing in patients with a CMR conditional cardiac resynchronization therapy defibrillator (CRT-D) and compared the results with invasive volume measurements. METHODS: Ten CRT-D patients underwent CMR imaging prior to device implantation (baseline) and six weeks after device implantation, including CRT-on and CRT-off modes. Left ventricular (LV) function, volumes, and strain measurements of LV dyssynchrony and dyscoordination were assessed. Invasive pressure-volume measurements were performed, matching the CRT settings used during CMR. RESULTS: Post-implantation imaging enabled reliable cine assessment, but showed artefacts on late gadolinium enhancement images. After six weeks of CRT, significant reverse remodeling was observed, with a 22.7 ± 11% reduction in LV end-systolic volume during intrinsic rhythm (CRT-off). During CRT-on, the LV ejection fraction significantly improved from 27.4 ± 5.9% to 32.2 ± 8.7% (p < 0.01), and the strain assessment showed the abolition of the left bundle branch block contraction pattern. Invasively measured and CMR-assessed LV hemodynamics during BIV pacing were significantly associated. CONCLUSIONS: Post-CRT implantation CMR assessing acute LV pump function is feasible and provides important insights into the effects of BIV pacing on cardiac function and contraction patterns. LV assessment during CMR may constitute a future CRT optimization strategy.

9.
Circ Cardiovasc Interv ; 15(11): 892-902, 2022 11.
Article in English | MEDLINE | ID: mdl-36305318

ABSTRACT

BACKGROUND: The invasive microvascular function indices, coronary flow reserve (CFR) and the index of microcirculatory resistance (IMR), exhibit a dynamic pattern after ST-segment-elevation myocardial infarction. The effects of microvascular injury on the evolution of the microvascular function and the prognostic significance of the evolution of microvascular function are unknown. We investigated the relationship between the temporal changes of CFR and IMR, and cardiovascular magnetic resonance-derived microvascular injury characteristics in reperfused ST-segment-elevation myocardial infarction patients, and their association with 1-month left ventricular ejection fraction and infarct size (IS). METHODS: In 109 ST-segment-elevation myocardial infarction patients who underwent angiography for primary percutaneous coronary intervention (PPCI) and at 1-month follow-up, invasive assessment of CFR and IMR were performed in the culprit artery during both procedures. Cardiovascular magnetic resonance was performed 2 to 7 days after PPCI and at 1 month and provided assessment of left ventricular ejection fraction, IS, microvascular obstruction, and intramyocardial hemorrhage. RESULTS: CFR and IMR significantly changed over 1 month (both, P<0.001). The absolute IMR change over 1 month (ΔIMR) showed association with both microvascular obstruction and intramyocardial hemorrhage presence (both, P=0.01). ΔIMR differed between patients with/without microvascular obstruction (P=0.02) and with/without intramyocardial hemorrhage (P=0.04) but not ΔCFR for both. ΔIMR demonstrated association with both left ventricular ejection fraction and IS at 1 month (P<0.001, P=0.001, respectively), but not ΔCFR for both. Receiver-operating characteristics curve analysis of ΔIMR showed a larger area under the curve than post-PPCI CFR and IMR, and ΔCFR to be associated with both 1-month left ventricular ejection fraction >50% and extensive IS (the highest quartile). CONCLUSIONS: In reperfused ST-segment-elevation myocardial infarction patients, CFR and IMR significantly improved 1 month after PPCI; the temporal change in IMR is closely related to the presence/absence of microvascular damage and IS. ΔIMR exhibits a stronger association for 1-month functional outcome than post-PPCI CFR, IMR, or ΔCFR.


Subject(s)
Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Ventricular Function, Left , Humans , Coronary Circulation , Hemorrhage , Microcirculation , Percutaneous Coronary Intervention/adverse effects , ST Elevation Myocardial Infarction/diagnostic imaging , ST Elevation Myocardial Infarction/therapy , Stroke Volume , Treatment Outcome
10.
Int J Cardiol ; 367: 105-114, 2022 11 15.
Article in English | MEDLINE | ID: mdl-36007668

ABSTRACT

BACKGROUND: Myocardial infarction leads to complex changes in left ventricular (LV) hemodynamics. It remains unknown how four-dimensional acute changes in LV-cavity blood flow kinetic energy affects LV-remodeling. METHODS AND RESULTS: In total, 69 revascularised ST-segment elevation myocardial infarction (STEMI) patients were enrolled. All patients underwent cardiovascular magnetic resonance (CMR) examination within 2 days of the index event and at 3-month. CMR examination included cine, late gadolinium enhancement, and whole-heart four-dimensional flow acquisitions. LV volume-function, infarct size (indexed to body surface area), microvascular obstruction, mitral inflow, and blood flow KEi (kinetic energy indexed to end-diastolic volume) characteristics were obtained. Adverse LV-remodeling was defined and categorized according to increase in LV end-diastolic volume of at least 10%, 15%, and 20%. Twenty-four patients (35%) developed at least 10%, 17 patients (25%) at least 15%, 11 patients (16%) at least 20% LV-remodeling. Demographics and clinical history were comparable between patients with/without LV-remodeling. In univariable regression-analysis, A-wave KEi was associated with at least 10%, 15%, and 20% LV-remodeling (p = 0.03, p = 0.02, p = 0.02, respectively), whereas infarct size only with at least 10% LV-remodeling (p = 0.02). In multivariable regression-analysis, A-wave KEi was identified as an independent marker for at least 10%, 15%, and 20% LV-remodeling (p = 0.09, p < 0.01, p < 0.01, respectively), yet infarct size only for at least 10% LV-remodeling (p = 0.03). CONCLUSION: In patients with STEMI, LV hemodynamic assessment by LV blood flow kinetic energetics demonstrates a significant inverse association with adverse LV-remodeling. Late-diastolic LV blood flow kinetic energetics early after acute MI was independently associated with adverse LV-remodeling.


Subject(s)
Myocardial Infarction , ST Elevation Myocardial Infarction , Contrast Media , Gadolinium , Hemodynamics , Humans , Magnetic Resonance Imaging, Cine/methods , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/pathology , ST Elevation Myocardial Infarction/diagnostic imaging , ST Elevation Myocardial Infarction/surgery , Ventricular Function, Left , Ventricular Remodeling
11.
Eur Heart J ; 43(33): 3118-3128, 2022 09 01.
Article in English | MEDLINE | ID: mdl-35708168

ABSTRACT

AIMS: The diagnostic performance of non-invasive imaging in patients with prior coronary artery disease (CAD) has not been tested in prospective head-to-head comparative studies. The aim of this study was to compare the diagnostic performance of qualitative single-photon emission computed tomography (SPECT), quantitative positron emission tomography (PET), and qualitative magnetic resonance imaging (MRI) in patients with a prior myocardial infarction (MI) or percutaneous coronary intervention (PCI). METHODS AND RESULTS: In this prospective clinical study, all patients with prior MI and/or PCI and new symptoms of ischaemic CAD underwent 99mTc-tetrofosmin SPECT, [15O]H2O PET, and MRI, followed by invasive coronary angiography with fractional flow reserve (FFR) in all coronary arteries. All modalities were interpreted by core laboratories. Haemodynamically significant CAD was defined by at least one coronary artery with an FFR ≤0.80. Among the 189 enrolled patients, 63% had significant CAD. Sensitivity was 67% (95% confidence interval 58-76%) for SPECT, 81% (72-87%) for PET, and 66% (56-75%) for MRI. Specificity was 61% (48-72%) for SPECT, 65% (53-76%) for PET, and 62% (49-74%) for MRI. Sensitivity of PET was higher than SPECT (P = 0.016) and MRI (P = 0.014), whereas specificity did not differ among the modalities. Diagnostic accuracy for PET (75%, 68-81%) did not statistically differ from SPECT (65%, 58-72%, P = 0.03) and MRI (64%, 57-72%, P = 0.052). Using FFR < 0.75 as a reference, accuracies increased to 69% (SPECT), 79% (PET), and 71% (MRI). CONCLUSION: In this prospective head-to-head comparative study, SPECT, PET, and MRI did not show a significantly different accuracy for diagnosing FFR defined significant CAD in patients with prior PCI and/or MI. Overall diagnostic performances, however, were discouraging and the additive value of non-invasive imaging in this high-risk population is questionable.


Subject(s)
Coronary Artery Disease , Fractional Flow Reserve, Myocardial , Myocardial Perfusion Imaging , Percutaneous Coronary Intervention , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Humans , Myocardial Perfusion Imaging/methods , Predictive Value of Tests , Prospective Studies , Tomography, X-Ray Computed
12.
Eur Heart J Cardiovasc Imaging ; 23(6): 836-845, 2022 06 01.
Article in English | MEDLINE | ID: mdl-34195800

ABSTRACT

AIMS: This study aims to explore cardiovascular magnetic resonance (CMR)-derived left ventricular (LV) function, strain, and infarct size characteristics in patients with transient ST-segment elevation myocardial infarction (TSTEMI) compared to patients with ST-segment and non-ST-segment elevation myocardial infarctions (STEMI and NSTEMI, respectively). METHODS AND RESULTS: In total, 407 patients were enrolled in this multicentre observational prospective cohort study. All patients underwent CMR examination 2-8 days after the index event. CMR cine imaging was performed for functional assessment and late gadolinium enhancement to determine infarct size and identify microvascular obstruction (MVO). TSTEMI patients demonstrated the highest LV ejection fraction and the most preserved global LV strain (longitudinal, circumferential, and radial) across the three groups (overall P ≤ 0.001). The CMR-defined infarction was less frequently observed in TSTEMI than in STEMI patients [77 (65%) vs. 124 (98%), P < 0.001] but was comparable with NSTEMI patients [77 (65%) vs. 66 (70%), P = 0.44]. A remarkably smaller infarct size was seen in TSTEMI compared to STEMI patients [1.4 g (0.0-3.9) vs. 13.5 g (5.3-26.8), P < 0.001], whereas infarct size was not significantly different from that in NSTEMI patients [1.4 g (0.0-3.9) vs. 2.1 g (0.0-8.6), P = 0.06]. Whilst the presence of MVO was less frequent in TSTEMI compared to STEMI patients [5 (4%) vs. 53 (31%), P < 0.001], no significant difference was seen compared to NSTEMI patients [5 (4%) vs. 5 (5%), P = 0.72]. CONCLUSION: TSTEMI yielded favourable cardiac LV function, strain, and infarct-related scar mass compared to STEMI and NSTEMI. LV function and infarct characteristics of TSTEMI tend to be more similar to NSTEMI than STEMI.


Subject(s)
Non-ST Elevated Myocardial Infarction , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Contrast Media , Gadolinium , Humans , Magnetic Resonance Imaging, Cine , Prospective Studies , Ventricular Function, Left
13.
Sci Rep ; 11(1): 5965, 2021 03 16.
Article in English | MEDLINE | ID: mdl-33727587

ABSTRACT

The pathophysiology behind thrombus formation in paroxysmal atrial fibrillation (AF) patients is very complex. This can be due to left atrial (LA) flow changes, remodeling, or both. We investigated differences for cardiovascular magnetic resonance (CMR)-derived LA 4D flow and remodeling characteristics between paroxysmal AF patients and patients without cardiac disease. In this proof-of-concept study, the 4D flow data were acquired in 10 patients with paroxysmal AF (age = 61 ± 8 years) and 5 age/gender matched controls (age = 56 ± 1 years) during sinus rhythm. The following LA and LA appendage flow parameters were obtained: flow velocity (mean, peak), stasis defined as the relative volume with velocities < 10 cm/s, and kinetic energy (KE). Furthermore, LA global strain values were derived from b-SSFP cine images using dedicated CMR feature-tracking software. Even in sinus rhythm, LA mean and peak flow velocities over the entire cardiac cycle were significantly lower in paroxysmal AF patients compared to controls [(13.1 ± 2.4 cm/s vs. 16.7 ± 2.1 cm/s, p = 0.01) and (19.3 ± 4.7 cm/s vs. 26.8 ± 5.5 cm/s, p = 0.02), respectively]. Moreover, paroxysmal AF patients expressed more stasis of blood than controls both in the LA (43.2 ± 10.8% vs. 27.8 ± 7.9%, p = 0.01) and in the LA appendage (73.3 ± 5.7% vs. 52.8 ± 16.2%, p = 0.04). With respect to energetics, paroxysmal AF patients demonstrated lower mean and peak KE values (indexed to maximum LA volume) than controls. No significant differences were observed for LA volume, function, and strain parameters between the groups. Global LA flow dynamics in paroxysmal AF patients appear to be impaired including mean/peak flow velocity, stasis fraction, and KE, partly independent of LA remodeling. This pathophysiological flow pattern may be of clinical value to explain the increased incidence of thromboembolic events in paroxysmal AF patients, in the absence of actual AF or LA remodeling.


Subject(s)
Atrial Fibrillation/diagnosis , Heart Atria/diagnostic imaging , Heart Atria/physiopathology , Hemodynamics , Imaging, Three-Dimensional , Atrial Fibrillation/complications , Atrial Fibrillation/etiology , Atrial Remodeling , Blood Flow Velocity , Disease Management , Disease Susceptibility , Electrocardiography , Humans , Image Interpretation, Computer-Assisted , Image Processing, Computer-Assisted , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging , Observer Variation , Thromboembolism/etiology
14.
Basic Res Cardiol ; 114(1): 1, 2018 11 12.
Article in English | MEDLINE | ID: mdl-30443679

ABSTRACT

Monocytes are involved in adverse left ventricular (LV) remodelling following myocardial infarction (MI). To provide therapeutic opportunities we aimed to identify gene transcripts in monocytes that relate to post-MI healing and evaluated intervention with the observed gene activity in a rat MI model. In 51 MI patients treated by primary percutaneous coronary intervention (PCI), the change in LV end-diastolic volume index (EDVi) from baseline to 4-month follow-up was assessed using cardiovascular magnetic resonance imaging (CMR). Circulating monocytes were collected at day 5 (Arterioscler Thromb Vasc Biol 35:1066-1070, 2015; Cell Stem Cell 16:477-487, 2015; Curr Med Chem 13:1877-1893, 2006) after primary PCI for transcriptome analysis. Transcriptional profiling and pathway analysis revealed that patients with a decreased LV EDVi showed an induction of type I interferon (IFN) signalling (type I IFN pathway: P value < 0.001; false discovery rate < 0.001). We subsequently administered 15,000 Units of IFN-α subcutaneously in a rat MI model for three consecutive days following MI. Cardiac function was measured using echocardiography and infarct size/cardiac inflammation using (immuno)-histochemical analysis. We found that IFN-α application deteriorated ventricular dilatation and increased infarct size at day 28 post-MI. Moreover, IFN-α changed the peripheral monocyte subset distribution towards the pro-inflammatory monocyte subset whereas in the myocardium, the presence of the alternative macrophage subset was increased at day 3 post-MI. Our findings suggest that induction of type I IFN signalling in human monocytes coincides with adverse LV remodelling. In rats, however, IFN-α administration deteriorated post-MI healing. These findings underscore important but also contradictory roles for the type I IFN response during cardiac healing following MI.


Subject(s)
Interferon Type I/metabolism , Monocytes/transplantation , Myocardial Infarction/metabolism , Myocardial Infarction/therapy , Ventricular Remodeling , Adult , Aged , Animals , Bone Marrow Transplantation/methods , Female , Humans , Interferon Type I/pharmacology , Male , Middle Aged , Monocytes/metabolism , Myocardial Infarction/pathology , Rats , Rats, Wistar , Signal Transduction/drug effects , Signal Transduction/physiology , Ventricular Remodeling/drug effects , Wound Healing/drug effects , Wound Healing/physiology
15.
Eur Radiol ; 28(12): 5171-5181, 2018 Dec.
Article in English | MEDLINE | ID: mdl-29948065

ABSTRACT

OBJECTIVES: The aim of the present study was to evaluate the diagnostic performances of strain and wall thickening analysis in discriminating among three types of myocardium after acute myocardial infarction: non-infarcted myocardium, infarcted myocardium without microvascular obstruction (MVO) and infarcted myocardium with MVO. METHODS: Seventy-one patients with a successfully treated ST-segment elevation myocardial infarction underwent cardiovascular magnetic resonance imaging at 2-6 days after reperfusion. The imaging protocol included conventional cine imaging, myocardial tissue tagging and late gadolinium enhancement. Regional circumferential and radial strain and associated strain rates were analyzed in a 16-segment model as were the absolute and relative wall thickening. RESULTS: Hyperenhancement was detected in 418 (38%) of 1096 segments and was accompanied by MVO in 145 (35%) of hyperenhanced segments. Wall thickening, circumferential and radial strain were all significantly diminished in segments with hyperenhancement and decreased even further if MVO was also present (all p < 0.001). Peak circumferential strain (CS) surpassed all other strain and wall thickening parameters in its ability to discriminate between hyperenhanced and non-enhanced myocardium (all p < 0.05). Furthermore, CS was superior to both absolute and relative wall thickening in differentiating infarcted segments with MVO from infarcted segments without MVO (p = 0.02 and p = 0.001, respectively). CONCLUSIONS: Strain analysis is superior to wall thickening in differentiating between non-infarcted myocardium, infarcted myocardium without MVO and infarcted myocardium with MVO. Peak circumferential strain is the most accurate marker of regional function. KEY POINTS: • CMR can quantify regional myocardial function by analysis of wall thickening on cine images and strain analysis of tissue tagged images. • Strain analysis is superior to wall thickening in differentiating between different degrees of myocardial injury after acute myocardial infarction. • Peak circumferential strain is the most accurate marker of regional function.


Subject(s)
Heart Ventricles/diagnostic imaging , Magnetic Resonance Imaging, Cine/methods , Myocardial Contraction/physiology , Myocardium/pathology , ST Elevation Myocardial Infarction/diagnosis , Ventricular Function, Left/physiology , Female , Humans , Male , Middle Aged , Myocardial Revascularization/methods , Prognosis , ST Elevation Myocardial Infarction/physiopathology , ST Elevation Myocardial Infarction/surgery
16.
Eur Radiol ; 28(2): 824-832, 2018 Feb.
Article in English | MEDLINE | ID: mdl-28821947

ABSTRACT

OBJECTIVES: Native T1 mapping and late gadolinium enhancement (LGE) imaging offer detailed characterisation of the myocardium after acute myocardial infarction (AMI). We evaluated the effects of microvascular injury (MVI) and intramyocardial haemorrhage on local T1 and T2* values in patients with a reperfused AMI. METHODS: Forty-three patients after reperfused AMI underwent cardiovascular magnetic resonance imaging (CMR) at 4 [3-5] days, including native MOLLI T1 and T2* mapping, STIR, cine imaging and LGE. T1 and T2* values were determined in LGE-defined regions of interest: the MI core incorporating MVI when present, the core-adjacent MI border zone (without any areas of MVI), and remote myocardium. RESULTS: Average T1 in the MI core was higher than in the MI border zone and remote myocardium. However, in the 20 (47%) patients with MVI, MI core T1 was lower than in patients without MVI (MVI 1048±78ms, no MVI 1111±89ms, p=0.02). MI core T2* was significantly lower in patients with MVI than in those without (MVI 20 [18-23]ms, no MVI 31 [26-39]ms, p<0.001). CONCLUSION: The presence of MVI profoundly affects MOLLI-measured native T1 values. T2* mapping suggested that this may be the result of intramyocardial haemorrhage. These findings have important implications for the interpretation of native T1 values shortly after AMI. KEY POINTS: • Microvascular injury after acute myocardial infarction affects local T1 and T2* values. • Infarct zone T1 values are lower if microvascular injury is present. • T2* mapping suggests that low infarct T1 values are likely haemorrhage. • T1 and T2* values are complimentary for correctly assessing post-infarct myocardium.


Subject(s)
Coronary Vessels/diagnostic imaging , Hemorrhage/diagnostic imaging , Magnetic Resonance Imaging , Myocardial Infarction/diagnostic imaging , Contrast Media , Coronary Vessels/pathology , Female , Gadolinium , Hemorrhage/pathology , Humans , Male , Microcirculation , Middle Aged , Myocardial Infarction/pathology , Myocardium/pathology
17.
PLoS One ; 12(6): e0180115, 2017.
Article in English | MEDLINE | ID: mdl-28644903

ABSTRACT

OBJECTIVES: To characterize the temporal alterations in native T1 and extracellular volume (ECV) of remote myocardium after acute myocardial infarction (AMI), and to explore their relation to left ventricular (LV) remodeling. METHODS: Forty-two patients with AMI successfully treated with primary PCI underwent cardiovascular magnetic resonance after 4-6 days and 3 months. Cine imaging, late gadolinium enhancement, and T1-mapping (MOLLI) was performed at 1.5T. T1 values were measured in the myocardial tissue opposite of the infarct area. Myocardial ECV was calculated from native- and post-contrast T1 values in 35 patients, using a correction for synthetic hematocrit. RESULTS: Native T1 of remote myocardium significantly decreased between baseline and follow-up (1002 ± 39 to 985 ± 30ms, p<0.01). High remote native T1 at baseline was independently associated with a high C-reactive protein level (standardized Beta 0.32, p = 0.04) and the presence of microvascular injury (standardized Beta 0.34, p = 0.03). ECV of remote myocardium significantly decreased over time in patients with no LV dilatation (29 ± 3.8 to 27 ± 2.3%, p<0.01). In patients with LV dilatation, remote ECV remained similar over time, and was significantly higher at follow-up compared to patients without LV dilatation (30 ± 2.0 versus 27 ± 2.3%, p = 0.03). CONCLUSIONS: In reperfused first-time AMI patients, native T1 of remote myocardium decreased from baseline to follow-up. ECV of remote myocardium decreased over time in patients with no LV dilatation, but remained elevated at follow-up in those who developed LV dilatation. Findings from this study may add to an increased understanding of the pathophysiological mechanisms of cardiac remodeling after AMI.


Subject(s)
Heart/diagnostic imaging , Myocardial Infarction/diagnostic imaging , Ventricular Remodeling , Biomarkers/blood , Contrast Media , Extracellular Space , Female , Follow-Up Studies , Gadolinium , Heart/physiopathology , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Myocardial Infarction/physiopathology , Myocardial Infarction/therapy , Prospective Studies , Severity of Illness Index , Treatment Outcome
18.
Cardiovasc Diabetol ; 16(1): 67, 2017 05 19.
Article in English | MEDLINE | ID: mdl-28526033

ABSTRACT

BACKGROUND: Multiple bloodglucose-lowering agents have been linked to cardiovascular events. Preliminary studies showed improvement in left ventricular (LV) function during glucagon-like peptide-1 receptor agonist administration. Underlying mechanisms, however, are unclear. The purpose of this study was to investigate myocardial perfusion and oxidative metabolism in type 2 diabetic (T2DM) patients with LV systolic dysfunction as compared to healthy controls. Furthermore, effects of 26-weeks of exenatide versus insulin glargine administration on cardiac function, perfusion and oxidative metabolism in T2DM patients with LV dysfunction were explored. METHODS AND RESULTS: Twenty-six T2DM patients with LV systolic dysfunction (cardiac magnetic resonance (CMR) derived LV ejection fraction (LVEF) of 47 ± 13%) and 10 controls (LVEF of 59 ± 4%, P < 0.01 as compared to patients) were analyzed. Both myocardial perfusion during adenosine-induced hyperemia (P < 0.01), and coronary flow reserve (P < 0.01), measured by [15O]H2O positron emission tomography (PET), were impaired in T2DM patients as compared to healthy controls. Myocardial oxygen consumption and myocardial efficiency, measured using [11C]acetate PET and CMR derived stroke volume, were not different between the groups. Eleven patients in the exenatide group and 12 patients in the insulin glargine group completed the trial. Systemic metabolic control was improved after both treatments, although, no changes in cardiac function, perfusion and metabolism were seen after exenatide or insulin glargine. CONCLUSIONS: T2DM patients with LV systolic dysfunction did not have altered myocardial efficiency as compared to healthy controls. Exenatide or insulin glargine had no effects on cardiac function, perfusion or oxidative metabolism. Trial registration NCT00766857.


Subject(s)
Coronary Circulation/drug effects , Diabetes Mellitus, Type 2/drug therapy , Diabetic Cardiomyopathies/drug therapy , Energy Metabolism/drug effects , Hypoglycemic Agents/therapeutic use , Incretins/therapeutic use , Insulin Glargine/therapeutic use , Myocardium/metabolism , Peptides/therapeutic use , Venoms/therapeutic use , Ventricular Dysfunction, Left/drug therapy , Ventricular Function, Left/drug effects , Aged , Diabetes Mellitus, Type 2/blood , Diabetes Mellitus, Type 2/complications , Diabetes Mellitus, Type 2/diagnosis , Diabetic Cardiomyopathies/diagnostic imaging , Diabetic Cardiomyopathies/etiology , Diabetic Cardiomyopathies/physiopathology , Exenatide , Female , Humans , Hypoglycemic Agents/adverse effects , Incretins/adverse effects , Insulin Glargine/adverse effects , Magnetic Resonance Imaging, Cine , Male , Middle Aged , Myocardial Perfusion Imaging/methods , Myocardium/pathology , Netherlands , Oxidation-Reduction , Oxygen Consumption , Peptides/adverse effects , Positron Emission Tomography Computed Tomography , Recovery of Function , Stroke Volume , Systole , Time Factors , Treatment Outcome , Venoms/adverse effects , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/etiology , Ventricular Dysfunction, Left/physiopathology
19.
J Nucl Cardiol ; 24(2): 657-667, 2017 04.
Article in English | MEDLINE | ID: mdl-26843199

ABSTRACT

BACKGROUND: Early recognition of viable myocardium after acute myocardial infarction (AMI) is of clinical relevance, since affected segments have the potential of functional recovery. Delayed contrast-enhanced magnetic resonance imaging (DCE-CMR) has been validated extensively for the detection of viable myocardium. An alternative parameter for detecting viability is the perfusable tissue index (PTI), derived using [15O]H2O positron emission tomography (PET), which is inversely related to the extent of myocardial scar (non-perfusable tissue). The aim of the present study was to investigate the predictive value of PTI on recovery of LV function as compared to DCE-CMR in patients with AMI, after successful percutaneous coronary intervention (PCI). METHODS: Thirty-eight patients with ST elevation myocardial infarction (STEMI) successfully treated by PCI were prospectively recruited. Subjects were examined 1 week and 3 months (mean follow-up time: 97 ± 10 days) after AMI using [15O]H2O PET and DCE-CMR to assess PTI, regional function and scar. Viability was defined as recovery of systolic wall thickening ≥3.0 mm at follow-up by use of CMR. A total of 588 segments were available for serial analysis. RESULTS: At baseline, 180 segments were dysfunctional and exhibited DCE. Seventy-three (41%) of these dysfunctional segments showed full recovery during follow-up (viable), whereas 107 (59%) segments remained dysfunctional (nonviable). Baseline PTI of viable segments was 0.94 ± 0.09 and was significantly higher compared to nonviable segments (0.80 ± 0.13, P < .001). The optimal cut-off value for PTI was ≥0.85 with a sensitivity of 85% and specificity of 72%, and an area under the curve (AUC) of 0.82. In comparison, a cut-off value of <32% for the extent of DCE resulted in a sensitivity of 72% and a specificity of 69%, and an AUC of 0.75 (AUC PTI vs DCE P = .14). CONCLUSION: Assessment of myocardial viability shortly after reperfused AMI is feasible using PET. PET-derived PTI yields a good predictive value for the recovery of LV function in PCI-treated STEMI patients, in excellent agreement with DCE-CMR.


Subject(s)
Magnetic Resonance Imaging, Cine/methods , Myocardial Perfusion Imaging/methods , Myocardial Stunning/diagnostic imaging , Myocardial Stunning/etiology , Positron-Emission Tomography/methods , ST Elevation Myocardial Infarction/complications , ST Elevation Myocardial Infarction/diagnostic imaging , Contrast Media , Early Diagnosis , Feasibility Studies , Female , Humans , Male , Middle Aged , Oxygen Radioisotopes , Radiopharmaceuticals , Reproducibility of Results , Sensitivity and Specificity , Water
20.
Thromb Res ; 137: 64-71, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26654718

ABSTRACT

INTRODUCTION: ST-elevated myocardial infarction (STEMI) is most frequently caused by coronary occlusion due to formation of an intracoronary thrombus in reaction to rupture of atherosclerotic plaques. Little is known about kinetics of coagulation markers after STEMI in patients treated according to current guidelines. We aimed to investigate kinetics of important coagulation markers in percutaneous coronary intervention (PCI)-treated STEMI patients. MATERIALS AND METHODS: 60 consecutive PCI-treated STEMI patients were prospectively included. Blood samples were collected immediately after as well as 1, 4 and 7 days following PCI. Samples collected 90 days after PCI served as baseline values. ADAMTS13 activity, VWF (von Willebrand factor) activity, VWF antigen, VWF propeptide, fibrinogen antigen, D-dimer, alpha2-antiplasmin (α2AP), plasmin-alpha2-antiplasmin complex (PAP), prothrombin fragment F1+2 (F1+2), prothrombin time (PT), activated partial thromboplastin time (aPTT), and anti-factor Xa (anti-Xa) were measured. Cardiac magnetic resonance (CMR) was performed at 4-6 and 90 days after PCI in 49 patients and left ventricular ejection fraction (LVEF), infarct size and microvascular injury (MVI) were determined. RESULTS: Immediately after PCI, ADAMTS13 activity, fibrinogen antigen and α2AP levels were significantly decreased and VWF activity, VWF antigen and VWF propeptide levels were significantly elevated, compared to baseline. Individual coagulation markers and different combinations thereof were not related to LVEF or infarct size at 90 days, or the occurrence of MVI at 4-6 days after PCI. CONCLUSION: Coagulation parameters show a very dynamic profile in the early days after STEMI. However, individual coagulation parameters or combinations thereof do not predict CMR-defined LVEF, infarct size or MVI.


Subject(s)
Blood Coagulation Factors/analysis , Coronary Artery Disease/diagnosis , Coronary Artery Disease/surgery , Myocardial Infarction/diagnosis , Myocardial Infarction/surgery , Coronary Artery Disease/blood , Female , Humans , Kinetics , Male , Middle Aged , Myocardial Infarction/blood , Percutaneous Coronary Intervention , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...