Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
J Mech Behav Biomed Mater ; 138: 105622, 2023 02.
Article in English | MEDLINE | ID: mdl-36538838

ABSTRACT

The trochanteric soft tissue attenuates impact force or absorbs impact energy during a fall on the hip (thereby helps to reduce a risk of hip fracture). While the benefits should be affected by contractions of muscles spanning the hip joint, no information is available to date. We examined how the stiffness (force attenuation capacity) and energy absorption of the trochanteric soft tissue were affected by hip muscle activation during a fall. Thirteen healthy young individuals (5 males, 8 females) participated in the pelvis release experiment. Falling trials were acquired with three muscle contraction conditions: 0-20% ("relaxed"), 20-50% ("moderate"), and 60-100% ("maximal") of the maximal voluntary isometric contraction of the gluteus medius muscle. During trials, we measured real-time force and deformation behaviour of the trochanteric soft tissue. Outcome variables included the stiffness and energy absorption of the soft tissue. The stiffness and energy absorption ranged from 56.1 to 446.9 kN/m, and from 0.15 to 2.26 J, respectively. The stiffness value increased with muscle contraction, and 59% greater in "maximal" than "relaxed" condition (232.2 (SD = 121.4) versus 146.1 (SD = 49.9)). However, energy absorption decreased with muscle contraction, and 58.9% greater in "relaxed" than "maximal" condition (0.89 (SD = 0.63) versus 0.56 (SD = 0.41)). Our results provide insights on biomechanics of the trochanteric soft tissue ("natural" padding device) during impact stage of a fall, suggesting that soft tissues' protective benefits are largely affected by the level of muscle contraction.


Subject(s)
Femur , Pelvis , Male , Female , Humans , Femur/physiology , Pelvis/physiology , Hip Joint , Muscle, Skeletal/physiology
2.
J Rehabil Assist Technol Eng ; 6: 2055668319877314, 2019.
Article in English | MEDLINE | ID: mdl-31839983

ABSTRACT

INTRODUCTION: Over 90% of hip fractures in older adults result from falls, and hospital patients are at especially high risk. Specific types of wearable hip protectors have been shown to reduce hip fracture risk during a fall by up to 80%, but user compliance has averaged less than 50%. We describe the development and evaluation of a "stick-on" hip protector (secured over the hip with a skin-friendly adhesive) for older patients in acute care. METHODS: An initial version of the product was evaluated with six female patients (aged 76-91) in a hospital ward, who were asked to wear it for one week. We subsequently refined the product through biomechanical testing and solicited feedback from 43 health professionals on a second prototype. RESULTS: The first prototype was worn by five of six patients for the full week or duration of their hospital stay. The second prototype (20 mm thick, surface area 19 × 15.5 cm) provided 36% force attenuation, more than common garment-based models (20-21%). Feedback from patients and health professionals highlighted usability, comfort, cost, and appearance. CONCLUSIONS: Our results from biomechanical and user testing support the need for further work to determine the value of stick-on hip protectors in acute care.

3.
J Biomech ; 74: 41-49, 2018 06 06.
Article in English | MEDLINE | ID: mdl-29691053

ABSTRACT

Improved understanding is required of how the mechanics of the fall affect hip fracture risk. We used a hip impact simulator to determine how peak stresses at the femoral neck were affected by pelvis impact angle, hip abductor muscle force, and use of a wearable hip protector. We simulated falls from standing (2 m/s impact velocity) involving initial hip abductor muscle forces of 700 or 300 N. Trials were acquired for impact to the lateral aspect of the greater trochanter, and impact to the pelvis rotated 5°, 10° and 15° anteriorly (positive) or posteriorly (negative). Measures were acquired with and without a commercially available hip protector. During trials, we measured three-dimensional forces with a load cell at the femoral neck, and derived peak compressive and tensile stresses. Peak compressive stress increased 37% (5.91 versus 4.31 MPa; p < 0.0005) and peak tensile stress increased 209% (2.31 versus 0.75 MPa; p < 0.0005) when the pelvis impact angle changed from 15° anterior to -15° posterior. For lateral impacts, the peak tensile and compressive stresses averaged 73% and 8% lower, respectively, in the 700 N than 300 N muscle force condition, but the effect was reversed for anteriolateral or posteriolateral impacts. The attenuation in peak compressive stress from the hip protector was greatest for posteriolateral impacts (-15 to -5°; 36-41%), and least for anteriolateral (+15°; 10%). These results clarify the effects on hip fracture risk during a fall of pelvis impact angle and muscle forces, and should inform the design of improved hip protectors.


Subject(s)
Accidental Falls , Femur Neck/physiology , Pelvis/physiology , Stress, Mechanical , Biomechanical Phenomena , Humans , Pressure , Tensile Strength
4.
Clin Biomech (Bristol, Avon) ; 49: 28-33, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28843128

ABSTRACT

Falls are a common cause of traumatic brain injuries (TBI) across the lifespan. A proposed but untested hypothesis is that neck muscle activation influences impact severity and risk for TBI during a fall. We conducted backward falling experiments to test whether activation of the neck flexor muscles facilitates the avoidance of head impact, and reduces impact velocity if the head contacts the ground. Young adults (n=8) fell from standing onto a 30cm thick gymnastics mat while wearing a helmet. Participants were instructed to fall backward and (a) prevent their head from impacting the mat ("no head impact" trials); (b) allow their head to impact the mat, but with minimal impact severity ("soft impact" trials); and (c) allow their head to impact the mat, while inhibiting efforts to reduce impact severity ("hard impact" trials). Trial type associated with peak magnitude of electromyographic activity of the sternocleidomastoid (SCM) muscles (p<0.017), and with the vertical and horizontal velocity of the head at impact (p<0.001). Peak SCM activations, expressed as percent maximal voluntary isometric contraction (%MVIC), averaged 75.3, 67.5, and 44.5%MVIC in "no head impact", "soft impact", and "hard impact" trials, respectively. When compared to "soft impact" trials, vertical impact velocities in "hard impact" trials averaged 87% greater (3.23 versus 1.73m/s) and horizontal velocities averaged 83% greater (2.74 versus 1.50m/s). For every 10% increase in SCM %MVIC, vertical impact velocity decreased 0.24m/s and horizontal velocity decreased 0.22m/s. We conclude that SCM activation contributes to the prevention and modulation of head impact severity during backward falls.


Subject(s)
Accidental Falls , Craniocerebral Trauma/physiopathology , Neck Muscles/physiology , Posture/physiology , Adult , Female , Humans , Isometric Contraction/physiology , Male , Young Adult
5.
Osteoporos Int ; 27(2): 537-47, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26252977

ABSTRACT

UNLABELLED: Hip fracture risk is increased by landing on the hip. We examined factors that contribute to hip impact during real-life falls in long-term care facilities. Our results indicate that hip impact is equally likely in falls initially directed forward as sideways and more common among individuals with dependent Activities of Daily Living (ADL) performance. INTRODUCTION: The risk for hip fracture in older adults increases 30-fold by impacting the hip during a fall. This study examined biomechanical and health status factors that contribute to hip impact through the analysis of real-life falls captured on video in long-term care (LTC) facilities. METHODS: Over a 7-year period, we captured 520 falls experienced by 160 residents who provided consent for releasing their health records. Each video was analyzed by a three-member team using a validated questionnaire to determine whether impact occurred to the hip or hand, the initial fall direction and landing configuration, attempts of stepping responses, and use of mobility aids. We also collected information related to resident physical and cognitive function, disease diagnoses, and use of medications from the Minimum Data Set. RESULTS: Hip impact occurred in 40 % of falls. Falling forward or sideways was significantly associated with higher odds of hip impact, compared to falling backward (OR 4.2, 95 % CI 2.4-7.1) and straight down (7.9, 4.1-15.6). In 32 % of sideways falls, individuals rotated to land backward. This substantially reduced the odds for hip impact (0.1, 0.03-0.4). Tendency for body rotation was decreased for individuals with dependent ADL performance (0.43, 0.2-1.0). CONCLUSIONS: Hip impact was equally likely in falls initially directed forward as sideways, due to the tendency for axial body rotation during descent. A rotation from sideways to backward decreased the odds of hip impact 10-fold. Our results may contribute to improvements in risk assessment and strategies to reduce risk for hip fracture in older adults.


Subject(s)
Accidental Falls/statistics & numerical data , Hip Fractures/etiology , Long-Term Care , Activities of Daily Living , Aged , Aged, 80 and over , Biomechanical Phenomena , British Columbia/epidemiology , Female , Hip Fractures/epidemiology , Hip Fractures/prevention & control , Humans , Male , Prevalence , Protective Devices , Risk Factors , Rotation , Video Recording
6.
J Biomech ; 48(6): 911-20, 2015 Apr 13.
Article in English | MEDLINE | ID: mdl-25769730

ABSTRACT

Falls cause 95% of hip and wrist fractures and 60% of head injuries in older adults. Risk for such injuries depends in part on velocity at contact, and the time available during the fall to generate protective responses. However, we have no information on the impact velocities and durations of falls in older adults. We addressed this barrier through kinematic analysis of 25 real-life falls (experienced by 23 individuals of mean age 80 years (SD=9.8)) captured on video in two long-term facilities. All 25 falls involved impact to the pelvis, 12 involved head impact, and 21 involved hand impact. We determined time-varying positions by digitizing each video, using direct linear transformations calibrated for each fall, and impact velocities through differentiation. The vertical impact velocity averaged 2.14 m/s (SD=0.63) for the pelvis, 2.91 m/s (SD=0.86) for the head, and 2.87 m/s (SD=1.60) for the hand. These values are 38%, 28%, and 4% lower, respectively, than predictions from an inverted pendulum model. Furthermore, the average pelvis impact velocity was 16% lower than values reported previously for young individuals in laboratory falling experiments. The average fall duration was 1271 ms (SD=648) from the initiation of imbalance to pelvis impact, and 583 ms (SD=255) from the start of descent to pelvis impact. These first measures of the kinematics of falls in older adults can inform the design and testing of fall injury prevention interventions (e.g., hip protectors, helmets, and flooring).


Subject(s)
Accidental Falls , Aged , Aged, 80 and over , Biomechanical Phenomena , Craniocerebral Trauma , Female , Hand Injuries , Humans , Long-Term Care , Male , Pelvis/injuries , Video Recording
7.
J Biomech ; 48(4): 695-700, 2015 Feb 26.
Article in English | MEDLINE | ID: mdl-25596629

ABSTRACT

Hip fracture risk increases dramatically with age, and 90% of fractures are due to falls. During a fall on the hip, the soft tissues overlying the hip region (skin, fat, and muscle) act as shock absorbers to absorb energy and reduce the peak force applied to the underlying bone. We conducted dynamic indentation experiments with young women (aged 19-30; n=17) and older women (aged 65-81; n=17) to test the hypothesis that changes occur with age in the stiffness and damping properties of these tissues. Tissue stiffness and damping were derived from experiments where subjects lay sideways on a bed with the greater trochanter contacting a 3.8cm diameter indenter, which applied sinusoidal compression between 5 to 30Hz with a peak-to-peak amplitude of 1mm. Soft tissue thickness was measured using ultrasound. On average, stiffness was 2.9-fold smaller in older than young women (5.7 versus 16.8kN/m, p=0.0005) and damping was 3.5-fold smaller in older than young women (81 versus 282Ns/m, p=0.001). Neither parameter associated with soft tissue thickness. Our results indicate substantial age-related reductions in the stiffness and damping of soft tissues over the hip region, which likely reduce their capacity to absorb and dissipate energy (before "bottoming out") during a fall. Strategies such as wearable hip protectors or compliant flooringmay compensate for age-related reductions in the shock-absorbing properties of soft tissues and decrease the injury potential of falls.


Subject(s)
Adipose Tissue/physiology , Aging/physiology , Compressive Strength/physiology , Femur/physiology , Muscle, Skeletal/physiology , Skin Physiological Phenomena , Accidental Falls , Adipose Tissue/diagnostic imaging , Adult , Aged , Aged, 80 and over , Biomechanical Phenomena/physiology , Elasticity/physiology , Female , Hip Fractures/epidemiology , Humans , Muscle, Skeletal/diagnostic imaging , Risk Factors , Skin/diagnostic imaging , Ultrasonography
8.
Osteoporos Int ; 26(1): 291-301, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25027112

ABSTRACT

UNLABELLED: Through experiments that simulated sideways falls with a mechanical hip impact simulator, we demonstrated the protective effect of hip abductor muscle forces in reducing peak stresses at the femoral neck and the corresponding risk for hip fracture. INTRODUCTION: Over 90% of hip fractures are due to falls, and an improved understanding the factors that separate injurious and non-injurious falls (via their influence on the peak stress generated at the femoral neck) may lead to improved risk assessment and prevention strategies. The purpose of this study was to measure the effect of muscle forces spanning the hip, and knee boundary conditions, on peak forces and estimated stresses at the femoral neck during simulated falls with a mechanical system. METHODS: We simulated hip abductor muscle forces and knee boundary conditions with a mechanical hip impact simulator and measured forces and stresses at the femoral neck during sideways falls. RESULTS: Peak compressive and tensile stresses, shear force, bending moment, and axial force are each associated with hip abductor muscle forces and knee boundary conditions (p < 0.0005). When muscle force increased from 400 to 1,200 N, peak compressive and tensile stresses decreased 24 and 56%, respectively. These effects were similar to the magnitude of decline in fracture strength associated with osteoporosis and arose from the tension-band effect of the muscle in reducing the bending moment by 37%. Furthermore, peak compressive and tensile stresses averaged 40 and 51% lower, respectively, in the free knee than fixed knee condition. CONCLUSIONS: Contraction of the hip abductor muscles at the moment of impact during a fall, and landing with the knee free of constraints, substantially reduced peak compressive and tensile stresses at the femoral neck and risk for femoral fracture in a sideways fall.


Subject(s)
Accidental Falls , Femur Neck/physiopathology , Hip Joint/physiopathology , Knee Joint/physiopathology , Muscle, Skeletal/physiopathology , Biomechanical Phenomena , Hip Fractures/etiology , Hip Fractures/physiopathology , Humans , Models, Anatomic , Stress, Mechanical
9.
Z Gerontol Geriatr ; 46(8): 720-6, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24271252

ABSTRACT

Objective measurement of real-world fall events by using body-worn sensor devices can improve the understanding of falls in older people and enable new technology to prevent, predict, and automatically recognize falls. However, these events are rare and hence challenging to capture. The FARSEEING (FAll Repository for the design of Smart and sElf-adapaive Environments prolonging INdependent livinG) consortium and associated partners strongly argue that a sufficient dataset of real-world falls can only be acquired through a collaboration of many research groups. Therefore, the major aim of the FARSEEING project is to build a meta-database of real-world falls. To establish this meta-database, standardization of data is necessary to make it possible to combine different sources for analysis and to guarantee data quality. A consensus process was started in January 2012 to propose a standard fall data format, involving 40 experts from different countries and different disciplines working in the field of fall recording and fall prevention. During a web-based Delphi process, possible variables to describe participants, falls, and fall signals were collected and rated by the experts. The summarized results were presented and finally discussed during a workshop at the 20th Conference of the International Society of Posture and Gait Research 2012, in Trondheim, Norway. The consensus includes recommendations for a fall definition, fall reporting (including fall reporting frequency, and fall reporting variables), a minimum clinical dataset, a sensor configuration, and variables to describe the signal characteristics.


Subject(s)
Accidental Falls/prevention & control , Actigraphy/standards , Information Storage and Retrieval/standards , Monitoring, Ambulatory/standards , Practice Guidelines as Topic , Telemedicine/standards , Transducers/standards , Actigraphy/instrumentation , Europe , Evidence-Based Medicine , Humans , Monitoring, Ambulatory/instrumentation , Telemedicine/instrumentation
10.
J Biomech ; 44(3): 532-9, 2011 Feb 03.
Article in English | MEDLINE | ID: mdl-21035120

ABSTRACT

Falls on the outstretched hands are the cause of over 90% of wrist fractures, yet little is known about bone loading during this event. We tested how the magnitude and distribution of pressure over the palm region during a forward fall is affected by foam padding (simulating a glove) and arm configuration, and by the faller's body mass index (BMI) and thickness of soft tissues over the palm region. Thirteen young women with high (n=7) or low (n=6) BMI participated in a "torso release experiment" that simulated falling on both outstretched hands with the arm inclined either at 20° or 40° from the vertical. Trials were acquired with and without a 5 mm thick foam pad secured to the palm. Outcome variables were the magnitude and location of peak pressure (d, θ) with respect to the scaphoid, total impact force, and integrated force applied to three concentric areas, including "danger zone" of 2.5 cm radius centered at the scaphoid. Soft tissue thickness over the palm was measured by ultrasound. The 5mm foam pad reduced peak pressure, and peak force to the danger zone, by 83% and 13%, respectively. Peak pressure was 77% higher in high BMI when compared with low BMI participants. Soft tissue thickness over the palm correlated positively with distance (d) (R=0.79, p=0.001) and force applied outside the danger zone (R=0.76, p=0.002), but did not correlate with BMI (R=0.43, p=0.14). The location of peak pressure was shunted 4 mm further from the scaphoid at 20° than that of 40° falls (d=25 mm (SD 8), θ=-9° (SD 17) in the 20° falls versus d=21 mm (SD 8), θ=-5° (SD 24) in the 40° falls). Peak force to the entire palm was 11% greater in 20° compared with 40° falls. These results indicate that even a 5 mm thick foam layer protects against wrist injury, by attenuating peak pressure over the palm during forward falls. Increased soft tissue thickness shunts force away from the scaphoid. However, soft tissue thickness is not predicted by BMI, and peak pressures are greater in high individuals than that of low BMI individuals. These results contribute to our understanding of the mechanics and prevention of wrist and hand injuries during falls.


Subject(s)
Accidental Falls , Wrist Injuries/prevention & control , Biomechanical Phenomena , Body Mass Index , Female , Hip Fractures/prevention & control , Humans , Stress, Mechanical
11.
Clin Biomech (Bristol, Avon) ; 25(1): 63-9, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19766363

ABSTRACT

BACKGROUND: We examined how a soft shell hip protector affects the magnitude and distribution of force to the hip during simulated falls, and how the protective effect depends on the fall direction and the amount of soft tissue padding over the hip. METHODS: Fourteen young women with either high or low body mass index participated in a "pelvis release experiment" that simulated falls resulting in either lateral, anterolateral or posterolateral impact to the pelvis with/without a soft shell hip protector. Outcome variables were the magnitude and location of peak pressure (d, theta) with respect to the greater trochanter, total impact force, and percent force applied to four defined hip regions. FINDINGS: The soft shell hip protector reduced peak pressure by 70%. The effect was two times greater in low than high body mass index individuals. The protector shunted the peak pressure distally along the shaft of the femur (d=52 mm (SD 22), theta=-21 degrees (SD 49) in the unpadded trials versus d=81 mm (SD 23), theta=-10 degrees (SD 35) in the padded trials). Peak force averaged 12% greater in posterolateral and 17% lower in anterolateral than lateral falls. INTERPRETATION: Our results indicate that the hip protector we tested had a much stronger protective benefit for low than high body mass index individuals. Next generation protectors might be developed for improved shunting of pressure away from the femur, improved protection during posterolateral falls, and greater force attenuation for low body mass index individuals.


Subject(s)
Acceleration , Accidental Falls/prevention & control , Body Mass Index , Hip Fractures/prevention & control , Hip Fractures/physiopathology , Hip Joint/physiopathology , Models, Biological , Protective Devices , Adolescent , Adult , Computer Simulation , Equipment Design , Equipment Failure Analysis , Female , Humans , Pressure , Young Adult
12.
Osteoporos Int ; 21(1): 1-10, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19806284

ABSTRACT

INTRODUCTION: While hip protectors are effective in some clinical trials, many, including all in community settings, have been unable to demonstrate effectiveness. This is due partly to differences in the design and analysis. The aim of this report is to develop recommendations for subsequent clinical research. METHODS: In November of 2007, the International Hip Protector Research Group met to address barriers to the clinical effectiveness of hip protectors. This paper represents a consensus statement from the group on recommended methods for conducting future clinical trials of hip protectors. RESULTS AND CONCLUSIONS: Consensus recommendations include the following: the use of a hip protector that has undergone adequate biomechanical testing, the use of sham hip protectors, the conduct of clinical trials in populations with annual hip fracture incidence of at least 3%, a run-in period with demonstration of adequate adherence, surveillance of falls and adherence, and the inclusion of economic analyses. Larger and more costly clinical trials are required to definitively investigate effectiveness of hip protectors.


Subject(s)
Hip Fractures/prevention & control , Protective Devices , Randomized Controlled Trials as Topic/methods , Accidental Falls , Hip Fractures/etiology , Humans , Research Design , Treatment Outcome
13.
J Biomech ; 43(5): 818-25, 2010 Mar 22.
Article in English | MEDLINE | ID: mdl-20018287

ABSTRACT

Wearable hip protectors represent a promising strategy for reducing risk for hip fracture from a sideways fall. However, small changes in pad positioning may influence their protective benefit. Using a mechanical hip impact simulator, we investigated how three marketed soft shell hip protectors attenuate and redistribute the impact force applied to the hip, and how this depends on displacement from their intended position by 2.5 or 5 cm superiorly, posteriorly, inferiorly or anteriorly. For centrally-placed protectors, peak pressure was reduced 93% below the unpadded value by a 16 mm horseshoe-shaped protector, 93% by a 14 mm horseshoe protector, and 94% by a 16 mm continuous protector. In unpadded trials, 83% of the total force was applied to the skin overlying the proximal femur (danger zone). This was lowered to 19% by the centrally placed 16 mm horseshoe protector, to 34% by the 14 mm horseshoe, and to 40% by the 16 mm continuous protector. Corresponding reductions in peak force delivered to the femoral neck (relative to unpadded) were 45%, 38%, and 20%, respectively. The protective benefit of all three protectors decreased with pad displacement. For example, displacement of protectors by 5 cm anteriorly caused peak femoral neck force to increase 60% above centrally-placed values, and approach unpadded values. These results indicate that soft shell hip protectors provide substantial protective benefits, but decline in performance with small displacements from their intended position. Our findings confirm the need for correct and stable positioning of hip protectors in garment design.


Subject(s)
Accidental Falls/prevention & control , Hip Fractures/prevention & control , Hip Fractures/physiopathology , Protective Devices , Equipment Design , Equipment Failure Analysis , Humans , Pressure , Stress, Mechanical
14.
Osteoporos Int ; 20(12): 1977-88, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19806286

ABSTRACT

INTRODUCTION: Hip protectors represent a promising strategy for preventing fall-related hip fractures. However, clinical trials have yielded conflicting results due, in part, to lack of agreement on techniques for measuring and optimizing the biomechanical performance of hip protectors as a prerequisite to clinical trials. METHODS: In November 2007, the International Hip Protector Research Group met in Copenhagen to address barriers to the clinical effectiveness of hip protectors. This paper represents an evidence-based consensus statement from the group on recommended methods for evaluating the biomechanical performance of hip protectors. RESULTS AND CONCLUSIONS: The primary outcome of testing should be the percent reduction (compared with the unpadded condition) in peak value of the axial compressive force applied to the femoral neck during a simulated fall on the greater trochanter. To provide reasonable results, the test system should accurately simulate the pelvic anatomy, and the impact velocity (3.4 m/s), pelvic stiffness (acceptable range: 39-55 kN/m), and effective mass of the body (acceptable range: 22-33 kg) during impact. Given the current lack of clear evidence regarding the clinical efficacy of specific hip protectors, the primary value of biomechanical testing at present is to compare the protective value of different products, as opposed to rejecting or accepting specific devices for market use.


Subject(s)
Hip Fractures/prevention & control , Hip Joint , Materials Testing/methods , Protective Devices/standards , Accidental Falls , Equipment Design , Evidence-Based Medicine/methods , Hip Fractures/etiology , Humans , Research Design , Stress, Mechanical
15.
Osteoporos Int ; 19(7): 1067-75, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18338098

ABSTRACT

INTRODUCTION: While hip protectors represent a promising strategy for preventing hip fractures, clinical efficacy has been limited by poor user compliance. Soft shell protectors may be more acceptable to users than traditional hard shell designs. However, before embarking on clinical trials to assess efficacy, laboratory experiments are required to determine how soft shell protectors affect the force applied during impact to the hip. This was the goal of the current study. METHODS: Fifteen women participated in "pelvis release experiments," which safely simulate the impact stage of a sideways fall. During the trials, we measured total impact force and mean pressure over the greater trochanter with the participant unpadded, and while wearing two commercially available soft shell protectors. RESULTS: Mean pressure over the greater trochanter was reduced by 76% by a 14-mm thick horseshoe-shaped protector and by 73% by a 16-mm thick continuous protector. Total force was reduced by 9% by the horseshoe and by 19% by the continuous protector. CONCLUSIONS: Soft shell hip protectors substantially reduce the pressure over the greater trochanter, while only modestly reducing total impact force during simulated sideways falls. These data support the need for clinical trials to determine whether soft shell protectors reduce hip fracture risk in vulnerable populations.


Subject(s)
Accidental Falls , Hip Fractures/prevention & control , Hip/physiology , Protective Devices/standards , Adolescent , Adult , Analysis of Variance , Biomechanical Phenomena , Female , Humans , Stress, Mechanical , Young Adult
16.
J Gerontol A Biol Sci Med Sci ; 56(1): M42-7, 2001 Jan.
Article in English | MEDLINE | ID: mdl-11193232

ABSTRACT

BACKGROUND: In the event of a slip or trip, one's ability to recover a stable upright stance by stepping should depend on (a) the configuration of the body at the instant of step contact and (b) the forces generated between the foot and ground during step contact. In this study, we tested whether these two variables associate with elderly subjects' ability to recover balance by taking a single backward step after sudden release from an inclined position. METHODS: Twenty-six community-dwelling subjects (12 women, 14 men) of mean age 75+/-4 (SD) years each underwent five trials in which they were suddenly released from a backward inclination of 7 degrees and instructed to "recover balance with a single step." Body segment motions and foot contact forces were analyzed to determine step contact times, stepping angles, body lean angles at step contact, and the magnitudes and times (after step contact) of peak foot-floor contact forces and peak sagittal-plane torques at the ankle, knee, and hip of the stepping leg. RESULTS: Fifty percent of subjects were predominantly single steppers (successful at recovering with a single step in greater than three of five trials), 27% were multiple steppers (successful in less than two of five trials), and 23% were mixed response steppers (successful in two of five or three of five trials). Recovery style associated with the ratio of stepping angle divided by body lean angle at step contact (p = .003), which averaged 1.4+/-0.5 for single steppers and 0.6+/-0.5 for multiple steppers, but not with step contact time, stepping angle, or contact forces and joint torques during step contact. CONCLUSIONS: These results suggest that elderly subjects' ability to recover balance with a single backward step depends primarily on the configuration of the body (in particular, the ratio of stepping angle to body lean angle) at step contact.


Subject(s)
Postural Balance/physiology , Posture , Aged , Biomechanical Phenomena , Exercise Test , Female , Humans , Male
17.
J Biomech Eng ; 123(6): 590-8, 2001 Dec.
Article in English | MEDLINE | ID: mdl-11783730

ABSTRACT

At least 280 000 hip fractures occur annually in the U.S. at an estimated cost of $9 billion. While over 90 percent of these are caused by falls, only about 2 percent of all falls result in hip fracture. Evidence suggests that the most important determinants of hip fracture risk during a fall are the body's impact velocity and configuration. Accordingly, protective responses for reducing impact velocity and the likelihood for direct impact to the hip, strongly influence fracture risk. One method for reducing the body's impact velocity and kinetic energy during a fall is to absorb energy in the lower extremity muscles during descent, as occurs during sitting and squatting. In the present study, we employed a series of in verted pendulum models to determine: (a) the theoretical effect of this mechanism on impact severity during a backward fall, and (b) the effect on impact severity of age-related declines (or exercise-induced enhancements) in lower extremity strength. Compared to the case of a fall with zero energy absorption in the lower extremity joints, best-case falls (which involved 81 percent activation of ankle and hip muscles, but only 23 percent activation of knees muscles) involved 79 percent attenuation (from 352 J to 74 J) in the body's vertical kinetic energy at impact (KEv), and 48 percent attenuation (from 3.22 to 1.68 m/s) in the downward velocity of the pelvis at impact (v(v)). Among the mechanisms responsible for this were: (1) eccentric contraction of lower extremity muscles during descent, which resulted in up to 150 J of energy absorption; (2) impact with the trunk in an upright configuration, which reduced the change in potential energy associated with the fall by 100 J; and (3) knee extension during the final stage of descent, which "transferred" up to 90 J of impact energy into horizontal (as opposed to vertical) kinetic energy. Declines in joint strength reduced the effectiveness of mechanisms (1) and (3), and thereby increased impact severity However, even with reductions of 80 percent in available torques, KEv was attenuated by 50 percent. This indicates the importance of both technique and strength in reducing impact severity. These results provide motivation for attempts to reduce elderly individuals' risk for fall-related injury through the combination of instruction in safe falling techniques and exercises that enhance lower extremity strength.


Subject(s)
Aged/physiology , Joints/physiology , Leg/physiology , Models, Biological , Muscle, Skeletal/physiology , Posture/physiology , Accidental Falls/prevention & control , Biomechanical Phenomena , Computer Simulation , Female , Humans , Muscle Contraction/physiology , Muscle Weakness/physiopathology , Nonlinear Dynamics , Torque
18.
J Orthop Trauma ; 14(6): 420-5, 2000 Aug.
Article in English | MEDLINE | ID: mdl-11001416

ABSTRACT

OBJECTIVE: To evaluate a new method of small fragment fixation in a medial malleolus fracture model. DESIGN/METHODS: The authors measured the pullout strength, resistance to shear stress, and speed of insertion of 4.0-millimeter partially threaded cancellous screws, 2.4-millimeter smooth K-wires, and a small fragment fixation system with 2.2-millimeter threaded K-wires. Pullout strength was tested in eighty-one synthetic foam blocks and resistance to shear stress in thirty synthetic tibias by use of a servohydraulic testing machine. Six randomized time trials with the threaded K-wires and cancellous screws were also conducted. RESULTS: Pullout strength increased with increasing foam density, increasing insertion depth, and varied with fixation method (p < 0.05). Maximum pullout strengths were as follows: partially threaded cancellous screws, 730+/-4 Newtons; threaded K-wires, 316+/-12 Newtons; and smooth K-wires, 172 +/-5 Newtons. Percent difference in pullout strength between the partially threaded cancellous screw and threaded K-wire diminished with increased depth of insertion and increased foam density. Offset axial load to initiate fracture displacement in a synthetic tibia model averaged 1540+/-138 Newtons for the partially threaded cancellous screws, 1,318+/-117 Newtons for the threaded K-wires, and 1,287+/-121 Newtons for the smooth K-wires (p > 0.05). Average time of fixation of a medial malleolar fragment by orthopedic surgeons with a variety of experience levels in a synthetic tibia with two threaded K-wires (114+/-8 seconds) was significantly faster (p < 0.05) than with two partially threaded cancellous screws (207+/-20 seconds). CONCLUSIONS: Threaded K-wires show substantial pullout strength and similar resistance to offset axial load when compared with partially threaded cancellous screws. These threaded K-wires offer an alternative for the internal fixation of medial malleolus fractures.


Subject(s)
Bone Screws/standards , Bone Wires/standards , Fracture Fixation, Internal/instrumentation , Tibial Fractures/surgery , Compressive Strength , Equipment Design , Humans , Materials Testing/instrumentation , Materials Testing/methods , Tensile Strength , Time Factors , Weight-Bearing
19.
Exerc Sport Sci Rev ; 28(2): 74-9, 2000 Apr.
Article in English | MEDLINE | ID: mdl-10902089

ABSTRACT

Falls and fall-related injuries are a major health problem for elderly people. Biomechanical studies provide important insight into the cause of such events and reveal new techniques for preventing them. The topics reviewed in this article include balance recovery, safe landing responses, impact forces during falls, and fracture prevention through exercise programs, hip pads, and energy-absorbing floors.


Subject(s)
Accidental Falls/prevention & control , Fractures, Bone/prevention & control , Muscle, Skeletal/physiology , Biomechanical Phenomena , Female , Fractures, Bone/etiology , Humans , Male , Postural Balance , Sensitivity and Specificity
20.
J Biomech ; 33(7): 863-70, 2000 Jul.
Article in English | MEDLINE | ID: mdl-10831761

ABSTRACT

Although the energy available during a fall from standing greatly exceeds that required to produce hip fracture, this occurs in only about 2% of falls in the elderly. This is thought to be due in part to one's ability to reduce the vertical impact velocity (nu(nu)) and kinetic energy (KE(nu)) of the body through energy absorption in the lower extremity muscles during descent. The present study tested the hypothesis that the magnitude and percent attenuation in nu(nu) and KE(nu) associate with the horizontal and vertical excursion of the body's center-of-gravity during descent. Measures were acquired of whole-body kinematics and lower extremity kinetics as young subjects underwent backward descents involving vertical drops of either thigh length (SIT) or lower extremity length (FALL), and horizontal pelvis excursions of either 33 or 66% of lower extremity length. In all trials, subjects attempted to "land as softly as possible." While attenuation in nu(nu) and KE(nu) (which averaged 62 and 92% respectively), did not associate with trial type, raw magnitudes of these parameters did, with nu(nu) averaging 2-fold greater, and KE(nu) averaging 6-fold greater, in 66% FALL than in 33% SIT or 66% SIT trials. This was due to a rapid increase in downward velocity accompanying the final stage of descent in 66% SIT and 66% FALL trials, which coincided with the knee moving posterior to the ankle. Accordingly, severe impacts likely accompany not only large fall heights, but also falls where the feet are thrown rapidly forward, as during a backward slip.


Subject(s)
Accidental Falls , Hip Fractures/prevention & control , Postural Balance/physiology , Adult , Biomechanical Phenomena , Biophysical Phenomena , Biophysics , Energy Transfer , Female , Hip Fractures/etiology , Humans , Male , Models, Biological , Movement , Rotation , Torque
SELECTION OF CITATIONS
SEARCH DETAIL
...