Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
J Strength Cond Res ; 2024 Jun 07.
Article in English | MEDLINE | ID: mdl-38857438

ABSTRACT

ABSTRACT: Buga, A, Decker, DD, Robinson, BT, Crabtree, CD, Stoner, JT, Arce, LF, El-Shazly, X, Kackley, ML, Sapper, TN, Anders, JPV, Kraemer, WJ, and Volek, JS. The VirTra V-100 is a test-retest reliable shooting simulator for measuring accuracy/precision, decision-making, and reaction time in civilians, police/SWAT, and military personnel. J Strength Cond Res XX(X): 000-000, 2024-Law-enforcement agencies and the military have increasingly used virtual reality (VR) to augment job readiness. However, whether VR technology captures consistent data for shooting performance evaluation has never been explored. We enrolled 30 adults (24 M/6 F) to examine test-retest reliability of the VirTra shooting simulator. Approximately 30% of the sample had a tactical background (PD/SWAT and military). Trained research staff familiarized subjects with how to shoot the infrared-guided M4 rifle at digitally projected targets. Subjects then performed 3 identical experimental shooting sessions (consecutive or separated by 1-2 days) that assessed accuracy/precision, decision-making, and reaction time. Key metrics comprised projectile Cartesian position ( x , y ), score, time, and throughput (score or accuracy divided by time). Test-retest reliability was measured with intraclass correlation coefficients (ICC). After each visit, subjects completed a perceptual survey to self-evaluate their shooting performance and perceived VR realism. The simulator captured 21 ballistic variables with good to excellent test-retest agreement, producing a global ICC of 0.78. Notable metrics were the individual projectile distances to the center of the target (0.81), shot group radius (0.91), time-to-first decision (0.97), decision-making throughput (0.95), and target transition reaction time (0.91). Subjects had positive self-evaluations about their shooting performance, with "confidence" increasing from baseline to the end of the study ( p = 0.014). The VirTra V-100 virtual ballistic shooting simulator captures data with a high degree of test-retest reliability and is easy to familiarize regardless of starting expertise levels, making it appropriate for use as a method to objectively track progress or a tactical research testing tool.

2.
Curr Hypertens Rep ; 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38888690

ABSTRACT

PURPOSE OF REVIEW: Hypertension-induced cardiac hypertrophy is widely known as a major risk factor for increased cardiovascular morbidity and mortality. Although exercise is proven to exert overall beneficial effects on hypertension and hypertension-induced cardiac hypertrophy, there are some concerns among providers about potential adverse effects induced by intense exercise, especially in hypertensive athletes. We will overview the underlying mechanisms of physiological and pathological hypertrophy and delineate the beneficial effects of exercise in young people with hypertension and consequent hypertrophy. RECENT FINDINGS: Multiple studies have demonstrated that exercise training, both endurance and resistance types, reduces blood pressure and ameliorates hypertrophy in hypertensives, but certain precautions are required for hypertensive athletes when allowing competitive sports: Elevated blood pressure should be controlled before allowing them to participate in high-intensity exercise. Non-vigorous and recreational exercise are always recommended to promote cardiovascular health. Exercise-induced cardiac adaptation is a benign and favorable response that reverses or attenuates pathological cardiovascular remodeling induced by persistent hypertension. Exercise is the most effective nonpharmacological treatment for hypertensive individuals. Distinction between recreational-level exercise and competitive sports should be recognized by medical providers when allowing sports participation for adolescents and young adults.

3.
Pediatrics ; 153(6)2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38757175

ABSTRACT

BACKGROUND AND OBJECTIVES: Entrustable professional activities (EPAs) will be used for initial certification by the American Board of Pediatrics by 2028. Less than half of pediatric fellowships currently use EPAs for assessment, yet all will need to adopt them. Our objectives were to identify facilitators and barriers to the implementation of EPAs to assess pediatric fellows and to determine fellowship program directors' (FPD) perceptions of EPAs and Milestones. METHODS: We conducted a survey of FPDs from 15 pediatric subspecialties. EPA users were asked about their implementation of EPAs, barriers encountered, and perceptions of EPAs. Nonusers were queried about deterrents to using EPAs. Both groups were asked about potential facilitators of implementation and their perceptions of Milestones. RESULTS: The response rate was 65% (575/883). Of these, 344 (59.8%) were EPA users and 231 (40.2%) were nonusers. Both groups indicated work burden as a barrier to implementation. Nonusers reported more barriers than users (mean [SD]: 7 [3.8] vs 5.8 [3.4], P < .001). Both groups identified training materials and premade assessment forms as facilitators to implementation. Users felt that EPAs were easier to understand than Milestones (89%) and better reflected what it meant to be a practicing subspecialty physician (90%). In contrast, nonusers felt that Milestones were easy to understand (57%) and reflected what it meant to be a practicing subspecialist (58%). CONCLUSIONS: Implementing EPA-based assessment will require a substantial investment by FPDs, facilitated by guidance and easily accessible resources provided by multiple organizations. Perceived barriers to be addressed include FPD time constraints, a need for additional assessment tools, and outcomes data.


Subject(s)
Fellowships and Scholarships , Pediatrics , Pediatrics/education , Humans , Clinical Competence , United States , Certification , Surveys and Questionnaires , Male , Female
4.
PLoS One ; 19(1): e0296523, 2024.
Article in English | MEDLINE | ID: mdl-38166036

ABSTRACT

PURPOSE: Ketogenic diets may positively influence cancer through pleiotropic mechanisms, but only a few small and short-term studies have addressed feasibility and efficacy in cancer patients. The primary goals of this study were to evaluate the feasibility and the sustained metabolic effects of a personalized well-formulated ketogenic diet (WFKD) designed to achieve consistent blood beta-hydroxybutyrate (ßHB) >0.5 mM in women diagnosed with stage IV metastatic breast cancer (MBC) undergoing chemotherapy. METHODS: Women (n = 20) were enrolled in a six month, two-phase, single-arm WFKD intervention (NCT03535701). Phase I was a highly-supervised, ad libitum, personalized WFKD, where women were provided with ketogenic-appropriate food daily for three months. Phase II transitioned women to a self-administered WFKD with ongoing coaching for an additional three months. Fasting capillary ßHB and glucose were collected daily; weight, body composition, plasma insulin, and insulin resistance were collected at baseline, three and six months. RESULTS: Capillary ßHB indicated women achieved nutritional ketosis (Phase I mean: 0.8 mM (n = 15); Phase II mean: 0.7 mM (n = 9)). Body weight decreased 10% after three months, primarily from body fat. Fasting plasma glucose, plasma insulin, and insulin resistance also decreased significantly after three months (p < 0.01), an effect that persisted at six months. CONCLUSIONS: Women diagnosed with MBC undergoing chemotherapy can safely achieve and maintain nutritional ketosis, while improving body composition and insulin resistance, out to six months.


Subject(s)
Breast Neoplasms , Diet, Ketogenic , Insulin Resistance , Insulins , Ketosis , Humans , Female , Breast Neoplasms/drug therapy , Feasibility Studies , 3-Hydroxybutyric Acid
5.
Pediatr Cardiol ; 2023 Dec 20.
Article in English | MEDLINE | ID: mdl-38117291

ABSTRACT

Entrustable professional activities (EPAs) are "observable essential tasks expected to be performed by a physician for safe patient care in practice." Six Pediatric Cardiology (PC) EPAs and their level of supervision (LOS) scales were developed by medical educators in PC using a modified Delphi process and reviewed by the Subspecialty Pediatrics Investigator Network (SPIN). However, their general use in assessment for PC fellows for graduation requirements has yet to be studied. The objective of this study was to determine the minimum LOS required for PC fellows to graduate and compare it with the minimum LOS expected for safe and effective practice for the six PC EPAs, from the perspective of the PC Fellowship Program Directors(FPD). All Fellowship Program Directors(FPD) of ACGME-accredited PC fellowships were surveyed through SPIN between April 2017 and August 2017. For each of the PC EPAs, the FPDs were asked to indicate the minimum LOS expected for graduation and whether they would allow a fellow to graduate if this level was not achieved and the minimum LOS expected for a practicing pediatric cardiologist to provide safe and effective patient care. The minimum LOS was defined as the LOS for which no more than 20% of FPDs would want a lower level. The survey response rate was 80% (47/59). The majority of the FPDs did not require a minimum LOS of five corresponding to unsupervised practice in any of the six PC EPAs at graduation. For EPAs related to imaging, arrhythmia management, and management of cardiac problems, the minimum LOS for graduation was 3, corresponding to being "trusted to perform a task with indirect supervision for most simple and a few complex cases." For the EPAs related to interventional cardiology, heart failure pulmonary hypertension, and cardiac intensive care, the minimum LOS for graduation was 2, corresponding to being "trusted to perform a task only with direct supervision and coaching." The minimum LOS considered necessary for safe and effective practice for all but one EPA was 3. For the EPA related to the management of cardiac problems, the minimum LOS for safe practice was 4, corresponding to being "trusted to execute tasks independently except for few complex and critical cases." Most PC FPDs reported they would not require fellows to achieve the highest entrustment level for any of the six PC EPAs for graduation. It is crucial that educational programs evolve to address these essential activities during training better and that stakeholders ensure that graduating PC fellows have adequate resources and infrastructure to continue professional development as early career pediatric cardiologists.

6.
Clin Nutr ESPEN ; 54: 277-287, 2023 04.
Article in English | MEDLINE | ID: mdl-36963874

ABSTRACT

BACKGROUND: Single doses of exogenous ketone salts (KS) transiently increase circulating beta-hydroxybutyrate (BHB) (∼1 mM; 1-2 h) regardless of starting levels of ketosis; however, no studies have explored how sustained use of KS influences measures of ketonemia and glycemia. OBJECTIVES: To determine the response to a hypocaloric, well-formulated ketogenic diet (KD), with and without the inclusion of two daily racemic KS doses (6 g R-BHB + 6 g S-BHB per serving) on 1) daily fasting capillary R-BHB and glucose (R-BHB/GLUfast), 2) bi-weekly 13 h diurnal BHB and glucose (R-BHB/GLUdiur), 3) three-hours post-KS ingestion kinetics (R-BHBKS), and 4) bi-weekly fasting plasma enantiomer-specific BHB (R/S-BHBplasma). METHODS: Non-diabetic adults with overweight and obesity were randomized to receive a precisely measured hypocaloric KD (∼75 %en of maintenance) for six weeks, supplemented twice-daily with KS or placebo (PL). A non-randomized comparison group was provided an isonitrogenous/isoenergetic low-fat diet (LFD). All meals were provided to subjects. Capillary blood was collected daily to measure R-BHB/GLUfast and hourly for R-BHB/GLUdiur. Plasma was collected to measure R/S-BHBplasma, insulin, fasting glucose, and insulin resistance (HOMA-IR). Total AUC was calculated using the trapezoidal method. RESULTS: Mean R-BHBfast increased significantly during KD + PL (1.0 mM BHB), an effect enhanced 26% during KD + KS. GLUfast AUC was -6% lower during KD + KS versus LFD. Mean R-BHBdiur increased 40% in KD + KS versus KD + PL, whereas GLUdiur decreased 13% during both KDs versus LFD. R-BHBKS peaked (Δ: ∼1 mM) 1 h after the morning KS dose, but not following the afternoon dose. Both R/S-BHBplasma increased during KD independent of KS inclusion. R-BHBplasma was 50-times greater compared to S-BHBplasma, and the KS augmented S-BHBplasma 50% more than PL. Fasting insulin and HOMA-IR decreased after 14 days independent of diet. CONCLUSIONS: A hypocaloric KD was effective at reducing diurnal glucose compared to a LFD independent of weight loss, but twice-daily racemic KS ingestion during KD augmented ketonemia, both as R- and S-BHB, and decreased mean fasting glucose beyond a KD alone. The hypoglycemic effects of KD in combination with exogenous ketones merit further investigation.


Subject(s)
Diet, Ketogenic , Ketosis , Adult , Humans , 3-Hydroxybutyric Acid , Salts , Ketone Bodies , Ketones , Glucose , Insulin , Fasting
7.
Exp Physiol ; 108(5): 715-727, 2023 05.
Article in English | MEDLINE | ID: mdl-36915239

ABSTRACT

NEW FINDINGS: What is the central question of the study? Can a novel, energy-dense and lightweight ketogenic bar (1000 kcal) consumed 3 h before exercise modulate steady-state incline rucksack march ('ruck') performance compared to isocaloric carbohydrate bars in recreationally active, college-aged men? What is the main finding and its importance? Acute ingestion of either nutritional bar sustained ∼1 h of exhaustive rucking with a 30% of body weight rucksack. This proof-of-concept study is the first to demonstrate that carbohydrate bars and lipid bars are equally feasible for preserving ruck performance. Novel ketogenic nutrition bars may have military-relevant applications to lessen carry load without compromising exercise capacity. ABSTRACT: Rucksack marches ('rucks') are strenuous, military-relevant exercises that may benefit from pre-event fuelling. The purpose of this investigation was to explore whether acute ingestion of carbohydrate- or lipid-based nutritional bars before rucking can elicit unique advantages that augment exercise performance. Recreationally active and healthy males (n = 29) were randomized and counterbalanced to consume 1000 kcal derived from a novel, energy-dense (percentage energy from carbohydrate/fat/protein: 5/83/12) ketogenic bar (KB), or isocaloric high-carbohydrate bars (CB; 61/23/16) 3 h before a time-to-exhaustion (TTE) ruck. Conditions were separated by a 1-week washout. The rucksack weight was standardized to 30% of bodyweight. Steady-state treadmill pace was set at 3.2 km/h (0.89 m/s) and 14% grade. TTE was the primary outcome; respiratory exchange ratio (RER), capillary ketones (R-ß-hydroxybutyrate), glucose and lactate, plus subjective thirst/hunger were the secondary outcomes. Mean TTE was similar between conditions (KB: 55 ± 25 vs. CB: 54 ± 22 min; P = 0.687). The RER and substrate oxidation rates revealed greater fat and carbohydrate oxidation after the KB and CB, respectively (all P < 0.0001). Capillary R-ßHB increased modestly after the KB ingestion (P < 0.0001). Neither bar influenced glycaemia. Lactate increased during the ruck independent of the condition (P < 0.0001). Thirst/fullness perceptions changed independent of the nutritional bar consumed. A novel KB nutritional bar produced equivalent TTE ruck results to the isocaloric CBs. The KB's energy density relative to CB (6.6 vs. 3.8 kcal/g) may provide a lightweight (-42% weight), pre-event fuelling alternative that does not compromise ruck physical performance.


Subject(s)
Carbohydrates , Exercise , Male , Humans , Young Adult , Oxidation-Reduction , 3-Hydroxybutyric Acid , Lactates , Dietary Carbohydrates/pharmacology
8.
Am J Med Genet A ; 185(1): 234-237, 2021 01.
Article in English | MEDLINE | ID: mdl-33098248

ABSTRACT

PBX1 encodes the pre-B cell leukemia homeobox transcription factor, a three amino acid loop extension (TALE) homeodomain transcription factor, which forms nuclear complexes with other TALE class homeodomain proteins that ultimately regulate target genes controlling organ patterning during embryogenesis. Heterozygous de novo pathogenic variants in PBX1 resulting in haploinsufficiency are associated with congenital anomalies of the kidneys and urinary tract, most commonly renal hypoplasia, as well as anomalies involving the external ear, branchial arch, heart, and genitalia, and they cause intellectual disability and developmental delay. Affected individuals described thus far have had de novo variants. Here, we report three related individuals with an inherited pathogenic intragenic PBX1 deletion with variable clinical features typical for this syndrome.


Subject(s)
Coloboma/genetics , Genetic Predisposition to Disease , Pre-B-Cell Leukemia Transcription Factor 1/genetics , Renal Insufficiency/genetics , Urogenital Abnormalities/genetics , Vesico-Ureteral Reflux/genetics , Adult , Child , Coloboma/diagnosis , Coloboma/pathology , Developmental Disabilities/diagnosis , Developmental Disabilities/genetics , Developmental Disabilities/pathology , Female , Haploinsufficiency/genetics , Humans , Infant , Intellectual Disability/diagnosis , Intellectual Disability/genetics , Intellectual Disability/pathology , Male , Mutation/genetics , Phenotype , Renal Insufficiency/diagnosis , Renal Insufficiency/pathology , Urogenital Abnormalities/pathology , Vesico-Ureteral Reflux/diagnosis , Vesico-Ureteral Reflux/pathology
9.
World J Pediatr Congenit Heart Surg ; 11(5): 666-668, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32853062

ABSTRACT

Prominent Eustachian valves, with obligate right-to-left shunts, have been reported as a cause of neonatal hypoxemia. This anomaly can present as an obstructive structure that inhibits antegrade flow through the tricuspid valve and furthermore contributes to right-to-left atrial shunting in the presence of a patent foramen ovale or atrial septal defect. This case highlights the evaluation and diagnostic workup for chronic hypoxemia in an adolescent female patient and considerations for percutaneous atrial septal defect closure.


Subject(s)
Cardiac Surgical Procedures/methods , Heart Septal Defects, Atrial/surgery , Hypoxia/etiology , Adolescent , Echocardiography , Female , Heart Septal Defects, Atrial/complications , Heart Septal Defects, Atrial/diagnosis , Humans , Hypoxia/diagnosis , Hypoxia/surgery
10.
Pediatr Cardiol ; 40(7): 1516-1522, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31392379

ABSTRACT

Previous pediatric exercise test criteria for aortic stenosis severity were based on cardiac catheterization assessment, whereas current criteria are based on echocardiographic valve gradients. We sought to correlate exercise test criteria with echocardiographic assessment of severity. We report 65 studies, 51 patients (mean age of 13 ± 4 years; 75% males), with aortic stenosis (AS) who had a maximal exercise test between 2005 and 2016. We defined three groups based on resting mean Doppler gradient across their aortic valve: severe AS (n = 10; gradient of ≥ 40 mmHg), moderate AS (n = 20; gradient 25-39 mmHg), and mild AS (n = 35; gradient ≤ 24 mmHg). We studied symptoms (chest pain) during exercise, resting electrocardiogram changes (left ventricular hypertrophy [LVH]), complex arrhythmias during exercise, change in exercise systolic blood pressure (SBP; delta SBP = peak SBP-resting SBP), exercise duration, work, echocardiogram parameters (LVH), and ST-T wave changes with exercise. Additionally, we compared work and delta SBP during exercise with 117 control males and females without heart disease. Severe AS patients have statistically significant differences when compared with mild AS in ST-T wave depression during exercise, LVH on resting electrocardiogram, and echocardiogram. There was a significant difference in delta SBP between severe AS and normal controls (delta SBP 21.6 vs. 46.2 mmHg), and between moderate AS and normal controls (delta SBP 32 vs. 46.2 mmHg). There were no significant complications during maximal exercise testing. Children with echocardiographic severe and moderate AS have exercise testing abnormalities. Exercise test criteria for severity of AS were validated for echocardiographic criteria for AS severity.


Subject(s)
Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/physiopathology , Echocardiography/methods , Exercise Test/methods , Adolescent , Child , Humans
11.
Pediatr Cardiol ; 40(4): 834-840, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30834959

ABSTRACT

Developing a standardized protocol for pediatric exercise laboratories is challenging. Our objective was to report normal pediatric values for a continuous non-steady state cycle ergometer ramp protocol to achieve 8-10 min of exercise based on sex and weight. One hundred seventeen patients (117) [mean age 13 ± 2.8 years, range 7-18 years (51% male)] referred for chest pain with normal cardiac evaluation underwent cardiopulmonary testing on a cycle ergometer. Patients entered one of the four continuous ramp protocols (10, 15, 20, and 25 W/min ramp) to achieve an expected peak workload of 3 W/kg at an increase of 0.3 to 0.35 W/kg/min. Exercise test outcomes measured included duration, peak heart rate, work, respiratory exchange ratio, peak oxygen consumption, peak blood pressure, and ventilatory anaerobic threshold. An exercise duration of 8-10 min was achieved in a majority of the study population; however, interactions with age (older, longer duration) and sex (males, longer duration) were present. Using our algorithm (0.3-0.35 W/kg × weight), we demonstrated four non-steady state ramp bike ergometer protocols (10, 15, 20, and 25 W/min) that can be applied to males and females of different ages and weights to achieve an exercise duration of 8-10 min.


Subject(s)
Exercise Test/methods , Exercise/physiology , Adolescent , Algorithms , Child , Female , Humans , Male , Oxygen Consumption/physiology , Reference Standards , Reference Values , United States
12.
Pediatr Cardiol ; 40(5): 901-908, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30852629

ABSTRACT

The incidence of late coronary complications is reported around 8% after arterial switch operation (ASO) for d-transposition of the great arteries, but the affected patients are usually asymptomatic. Exercise stress test (EST) and myocardial perfusion imaging (MPI) are common non-invasive modalities to screen for silent myocardial ischemia, but their diagnostic reliability in children after ASO is unclear. We retrospectively reviewed asymptomatic patients following ASO with EST, MPI, and coronary imaging studies (CIS) and examined the reliability of each test in identifying abnormal coronary lesions responsible for myocardial ischemia. Thirty-seven asymptomatic patients (24 males; ages 12.7 ± 3.7 years) had EST, in which 27 and 33 patients also underwent MPI and CIS, respectively. Exercise capacity was comparable to the age- and sex-matched 37 controls. In seven patients with angiographically proven moderate to severe coronary abnormalities, only two patients had positive EST and/or MPI, and five patients were negative including one patient who later developed exercise-induced cardiac arrest due to severe proximal left coronary artery stenosis. Two patients with positive EST or MPI showed no corresponding coronary abnormalities by CIS. Occurrence of acquired late coronary abnormalities did not correlate with the original coronary anatomy or initial surgical procedures. There is no single reliable method to identify the risk of myocardial ischemia after ASO. Although CIS are regarded as a gold standard, multidisciplinary studies are essential to risk-stratify the potential life-threatening coronary lesions after ASO in children.


Subject(s)
Arterial Switch Operation/adverse effects , Myocardial Ischemia/diagnosis , Transposition of Great Vessels/surgery , Adolescent , Asymptomatic Diseases , Case-Control Studies , Child , Coronary Angiography , Exercise Test , Female , Humans , Magnetic Resonance Imaging , Male , Myocardial Perfusion Imaging , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies
13.
Circ J ; 79(11): 2372-9, 2015.
Article in English | MEDLINE | ID: mdl-26289969

ABSTRACT

BACKGROUND: The incidence of late coronary artery abnormalities after arterial switch operation (ASO) for d-loop transposition of the great arteries may be underestimated. METHODS AND RESULTS: We retrospectively reviewed coronary artery morphology in 40 of 97 patients who survived the first year after ASO. Seven asymptomatic patients developed significant late coronary artery abnormalities. One patient died suddenly at home with severe left coronary artery (LCA) ostial stenosis at age 3.8 years. The second patient collapsed during exercise at age 9.6 years due to ventricular fibrillation and severe LCA ostial stenosis despite prior negative exercise stress test (EST) and myocardial perfusion imaging (MPI). The third patient was found to have moderate ostial stenosis of the LCA with negative EST and MPI. The fourth patient with exercise-induced ST-T depression and myocardial perfusion defect was shown to have complete LCA occlusion with collateral vessel formation. Three other patients had complete proximal obliteration of either of the coronary arteries with collateral supply. An additional 4 asymptomatic patients had trivial-mild narrowing of the LCA on routine selective coronary angiogram. CONCLUSIONS: Incidence of late coronary stenosis or occlusion was not infrequent after ASO (11.3%) and presented usually without preceding symptoms and often after negative non-invasive screening. We advocate routine coronary imaging in all patients after ASO before they participate in competitive sports.


Subject(s)
Cardiac Surgical Procedures/adverse effects , Coronary Stenosis/etiology , Coronary Vessels , Transposition of Great Vessels/surgery , Biopsy , Cardiac Surgical Procedures/mortality , Child , Child, Preschool , Collateral Circulation , Coronary Angiography , Coronary Circulation , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/mortality , Coronary Stenosis/physiopathology , Coronary Vessels/diagnostic imaging , Coronary Vessels/physiopathology , Delaware , Female , Hemodynamics , Hospitals, Pediatric , Humans , Incidence , Infant , Infant, Newborn , Male , Retrospective Studies , Risk Factors , Time Factors , Transposition of Great Vessels/diagnosis , Transposition of Great Vessels/mortality , Treatment Outcome
14.
Am J Med Genet ; 112(4): 397-9, 2002 Nov 01.
Article in English | MEDLINE | ID: mdl-12376944

ABSTRACT

A 20-year-old female with trisomy 18 is described. Survival past infancy is rare in this disorder. Little is known concerning the factors that contribute to prolonged survival with this syndrome. This case provides an opportunity to review the management of older children and young adults with trisomy 18.


Subject(s)
Chromosomes, Human, Pair 18/genetics , Tetralogy of Fallot/pathology , Trisomy , Abnormalities, Multiple/genetics , Abnormalities, Multiple/pathology , Adult , Echocardiography , Female , Growth Disorders/pathology , Humans , Tetralogy of Fallot/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...