J Am Coll Cardiol ; 71(11): 1246-1254, 2018 03 20.
Article in English | MEDLINE | ID: mdl-29544609

ABSTRACT

BACKGROUND: Transesophageal echocardiography operators (TEEOP) provide critical imaging support for percutaneous structural cardiac intervention procedures. They stand close to the patient and the associated scattered radiation. OBJECTIVES: This study sought to investigate TEEOP radiation dose during percutaneous structural cardiac intervention. METHODS: Key personnel (TEEOP, anesthetist, primary operator [OP1], and secondary operator) wore instantly downloadable personal dosimeters during procedures requiring TEE support. TEEOP effective dose (E) and E per unit Kerma area product (E/KAP) were calculated. E/KAP was compared with C-arm projections. Additional shielding for TEEOP was implemented, and doses were measured for a further 50 procedures. Multivariate linear regression was performed to investigate independent predictors of radiation dose reduction. RESULTS: In the initial 98 procedures, median TEEOP E was 2.62 µSv (interquartile range [IQR]: 0.95 to 4.76 µSv), similar to OP1 E: 1.91 µSv (IQR: 0.48 to 3.81 µSv) (p = 0.101), but significantly higher than secondary operator E: 0.48 µSv (IQR: 0.00 to 1.91 µSv) (p < 0.001) and anesthetist E: 0.48 µSv (IQR: 0.00 to 1.43 µSv) (p < 0.001). Procedures using predominantly right anterior oblique (RAO) and steep RAO projections were associated with high TEEOP E/KAP (p = 0.041). In a further 50 procedures, with additional TEEOP shielding, TEEOP E was reduced by 82% (2.62 µSv [IQR: 0.95 to 4.76] to 0.48 µSv [IQR: 0.00 to 1.43 µSv] [p < 0.001]). Multivariate regression demonstrated shielding, procedure type, and KAP as independent predictors of TEEOP dose. CONCLUSION: TEE operators are exposed to a radiation dose that is at least as high as that of OP1 during percutaneous cardiac intervention. Doses were higher with procedures using predominantly RAO projections. Radiation doses can be significantly reduced with the use of an additional ceiling-suspended lead shield.


Subject(s)
Echocardiography, Transesophageal , Occupational Exposure , Percutaneous Coronary Intervention/methods , Radiation Exposure , Radiation Protection/methods , Australia , Echocardiography, Transesophageal/adverse effects , Echocardiography, Transesophageal/methods , Female , Humans , Male , Occupational Exposure/analysis , Occupational Exposure/prevention & control , Outcome Assessment, Health Care , Radiation Dosage , Radiation Exposure/analysis , Radiation Exposure/prevention & control
SELECTION OF CITATIONS
SEARCH DETAIL
...