Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Case Rep Endocrinol ; 2022: 4044602, 2022.
Article in English | MEDLINE | ID: mdl-35083088

ABSTRACT

An adrenal myelolipoma presenting with suspicious features may pose a diagnostic challenge to surgeons and endocrinologists. In this case report of an adult patient with undiagnosed congenital adrenal hyperplasia presenting with bilateral adrenal masses, we review his radiographic and clinical findings which were highly suspicious for adrenal malignancy. Features of adrenal myelolipoma that may resemble malignant lesions are reviewed. This case report highlights important features of adrenal myelolipoma that the surgeon and endocrinologist should be aware of. The importance of avoiding overtreating adrenal myelolipomas presenting as tumors of uncertain malignant potential is crucial.

2.
Anat Sci Educ ; 13(3): 413-425, 2020 May.
Article in English | MEDLINE | ID: mdl-31232510

ABSTRACT

Simulation training has become increasingly relevant in the educational curriculum of surgical trainees. The types of simulation models used, goals of simulation training, and an objective assessment of its utility and effectiveness are highly variable. The role and effectiveness of cadaveric simulation in cardiothoracic surgical training has not been well established. The objective of this study was to evaluate the current medical literature available on the utility and the effectiveness of cadaveric simulation in cardiothoracic surgical residency training. A literature search was performed using PubMed, Cochrane Library, Embase, Scopus, and CINAHL from inception to February 2019. Of the 362 citations obtained, 23 articles were identified and retrieved for full review, yielding ten eligible articles that were included for analysis. One additional study was identified and included in the analysis. Extraction of data from the selected articles was performed using predetermined data fields, including study design, study participants, simulation task, performance metrics, and costs. Most of these studies were only descriptive of a cadaveric or perfused cadaveric simulation model that could be used to augment clinical operative training in cardiothoracic surgery. There is a paucity of evidence in the literature that specifically evaluates the utility and the efficacy of cadavers in cardiothoracic surgery training. Of the few studies that have been published in the literature, cadaveric simulation does seem to have a role in cardiothoracic surgery training beyond simply learning basic skills. Additional research in this area is needed.


Subject(s)
Cadaver , High Fidelity Simulation Training/methods , Internship and Residency/methods , Thoracic Surgery/education , Clinical Competence/statistics & numerical data , Curriculum , Humans , Internship and Residency/statistics & numerical data , Learning
3.
Innovations (Phila) ; 14(2): 159-167, 2019 Apr.
Article in English | MEDLINE | ID: mdl-31039682

ABSTRACT

OBJECTIVE: Aortic root enlargement may be necessary to implant adequately sized valves to avoid patient-prosthetic mismatch. Our objective was to assess the feasibility of annular enlargement during aortic valve replacement via a right anterior minithoracotomy. METHODS: Twelve consecutive patients undergoing elective minimally invasive aortic valve replacement requiring annular enlargement over a 2-year period were retrospectively reviewed. A right anterior minithoracotomy was performed in all patients. Cardiopulmonary bypass and aortic crossclamp times, hospital length of stay, postoperative complications, rate of reoperation, echocardiographic data, and mortality were analyzed. RESULTS: Mean age was 66 years ± 14. Mean body mass index was 34 ± 7.8 kg/m2. All patients had normal preoperative ejection fractions. Indications for aortic valve replacement were severe (3/12, 25%) or critical (9/12, 75%) aortic stenosis due to degenerative aortic valve disease (10/12, 83%) and congenitally bicuspid aortic valve (2/12, 17%). Cardiopulmonary bypass and aortic crossclamp times were 144.7 ± 14.7 minutes and 111.7 ± 10.6 minutes, respectively. The median postoperative length of stay was 4 days. Peak and mean aortic valve gradients on postreplacement intraoperative transesophageal echocardiography were 14.5 ± 9.4 mmHg and 7.2 ± 4.2 mmHg, respectively, with no perivalvular leak on intraoperative or follow-up transthoracic echocardiogram. Postoperative transthoracic echocardiography had peak and mean aortic valve gradients of 12.1 ± 6.9 mmHg and 6.3 ± 3.7 mmHg, respectively. There were no postoperative mortalities. Freedom from reoperation was 100%. CONCLUSIONS: Annular enlargement performed during minimally invasive aortic valve replacement is feasible. Basic minimally invasive skills are recommended prior to instituting these more advanced techniques.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Cardiac Valve Annuloplasty/methods , Heart Valve Prosthesis Implantation/methods , Minimally Invasive Surgical Procedures/methods , Aged , Aged, 80 and over , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Aortic Valve Stenosis/ethnology , Cardiac Valve Annuloplasty/mortality , Cardiopulmonary Bypass/standards , Echocardiography/methods , Feasibility Studies , Female , Heart Valve Prosthesis Implantation/mortality , Humans , Length of Stay , Middle Aged , Postoperative Complications , Retrospective Studies , Thoracotomy/methods , Thoracotomy/trends
4.
Ann Thorac Surg ; 107(1): 128-134, 2019 01.
Article in English | MEDLINE | ID: mdl-30170012

ABSTRACT

BACKGROUND: Optimal pain control continues to be a concern in cardiac surgery. Current strategies for postoperative pain management often yield suboptimal results. The superiority of Exparel (Pacira Pharmaceuticals, Inc, Parsippany, NJ) in providing postoperative pain control and opioid sparing is equivocal. This prospective, randomized, double-blind study examines the efficacy of Exparel as a novel single-dose application parasternal nerve block in postoperative pain control and opioid sparing. METHODS: This single-surgeon study included 79 patients undergoing median sternotomy for coronary revascularization. Study participants were randomized to either the drug or a control arm. Each participant received Exparel or normal saline placebo administered as a parasternal nerve block. Postoperative pain was rated according to the nonverbal pain scale or numeric rating scale. Total amount of narcotic pain medication used and patients' pain scores within the first 72 hours postoperatively were compared. Secondary outcomes compared the intensive care unit length of stay, hospital length of stay, time to extubation, time to return of bowel function, and time to return to work or daily activities. RESULTS: The primary endpoint of pain levels between the two groups demonstrated no significant difference when analyzing the individual time points postoperatively. However, overall pain levels were significantly lower in the study drug group (p = 0.04). There was no significant difference in the amount of analgesics required postoperatively or in secondary endpoints between the groups. CONCLUSIONS: Exparel does not provide an opioid-sparing benefit or any secondary outcome benefit compared with placebo. Exparel may be associated with a marginal decrease in postoperative pain levels. (Parasternal Nerve Bock in Cardiac Patients; NCT01826851.).


Subject(s)
Bupivacaine/administration & dosage , Nerve Block/methods , Pain, Postoperative/drug therapy , Sternotomy/methods , Aged , Anesthetics, Local/administration & dosage , Cardiac Surgical Procedures/methods , Double-Blind Method , Female , Follow-Up Studies , Humans , Intercostal Nerves , Male , Middle Aged , Pain Measurement , Pain, Postoperative/diagnosis , Prospective Studies , Treatment Outcome
5.
Innovations (Phila) ; 13(6): 428-432, 2018.
Article in English | MEDLINE | ID: mdl-30547896

ABSTRACT

OBJECTIVE: Subaortic membrane is an anatomical intracardiac anomaly that may cause discrete subaortic stenosis and aortic insufficiency. Patients requiring subaortic membrane resection may benefit from a minimally invasive approach; however, subaortic membranes are typically resected through a median sternotomy. We present our initial clinical experience of adult patients who have undergone a mini-thoracotomy subaortic membrane resection. METHODS: Eight patients who underwent an elective subaortic membrane resection performed through a mini-thoracotomy were retrospectively reviewed. A 5-cm mini-thoracotomy incision was made in the 2nd intercostal space; a videoscope was inserted through a separate incision within the same interspace. Cardiopulmonary bypass (CPB) was instituted via central arterial and peripheral venous cannulation and an aortotomy was made. The subaortic membrane was resected with shafted instruments. The left ventricular outflow tract was inspected and CPB was weaned. Thirty-day mortality, intensive care and hospital length of stay, ventilation time, operative times, postoperative morbidity, and need for additional procedures were evaluated. RESULTS: The median CPB and cross-clamp times were 60 and 42 minutes, respectively. The median time to extubation was 3.6 hours. The median intensive care unit and hospital stay were 22 hours and 3 days, respectively. The postoperative left ventricular outflow tract mean gradients decreased significantly (26.5 vs. 9.4 mm Hg, P = 0.001). There were no conversions to sternotomy, perioperative strokes, or 30-day mortality. CONCLUSIONS: Subaortic membranes can be resected through a mini-thoracotomy approach with excellent clinical results.


Subject(s)
Aorta/surgery , Thoracic Surgery, Video-Assisted/methods , Thoracotomy/methods , Adult , Aged , Cardiopulmonary Bypass , Female , Humans , Length of Stay/statistics & numerical data , Male , Middle Aged , Postoperative Complications/epidemiology , Reoperation/statistics & numerical data , Retrospective Studies , Thoracic Surgery, Video-Assisted/adverse effects , Thoracic Surgery, Video-Assisted/statistics & numerical data , Thoracotomy/adverse effects , Thoracotomy/statistics & numerical data
6.
Innovations (Phila) ; 13(5): 361-364, 2018.
Article in English | MEDLINE | ID: mdl-30394954

ABSTRACT

OBJECTIVE: The objective of this study was to investigate the feasibility of using titanium fasteners for securement of the inflow sewing ring during HeartMate 3 implantation. The secondary objective was to compare cardiopulmonary bypass and total operative times between the titanium fastener and hand-tied knot groups. METHODS: Clearance between the sewing ring and the HeartMate 3 device was assessed in vitro. Thirty-one patients undergoing HeartMate 3 implantation via median sternotomy at a single center from April 2017 to February 2018 were reviewed. The sewing ring was secured with hand-tied knots (n = 18) or titanium fasteners (n = 13). Cannulation strategy and implantation technique were otherwise identical between groups. Central arterial and venous cannulation was performed for cardiopulmonary bypass. The left ventricular apex was cored, and the sewing ring was attached with hand-tied knots or titanium fasteners. RESULTS: There was adequate clearance for the titanium fastener to secure the inflow sewing ring and then connect to the HeartMate 3 in vitro. The inflow sewing ring was successfully secured during HeartMate 3 implantation in the titanium fastener group. Cardiopulmonary bypass time was 75 and 92 minutes for the titanium fastener and hand-tied groups, respectively (P < 0.03). Total operative time was 177 and 193 minutes for the titanium fastener and hand-tied groups, respectively (P = 0.513). CONCLUSIONS: The inflow sewing ring of the HeartMate 3 was efficiently secured using titanium fasteners. Titanium fasteners resulted in shorter cardiopulmonary bypass times compared with the hand-tied group. There was no difference in total operative time.


Subject(s)
Cardiac Surgical Procedures , Heart-Assist Devices , Minimally Invasive Surgical Procedures/methods , Prosthesis Implantation/methods , Titanium/therapeutic use , Cardiac Surgical Procedures/instrumentation , Cardiac Surgical Procedures/methods , Female , Heart Failure/surgery , Humans , Male , Middle Aged , Operative Time , Prosthesis Design , Retrospective Studies
7.
Innovations (Phila) ; 13(5): 328-331, 2018.
Article in English | MEDLINE | ID: mdl-30407927

ABSTRACT

OBJECTIVE: Bentall procedures are traditionally performed through a median sternotomy. The right mini-thoracotomy approach is increasingly used in aortic valve replacement. This approach has been shown to have decreased blood loss and hospital length of stay compared with sternotomy. A right mini-thoracotomy approach may also be beneficial in selected patients requiring aortic root surgery. We present our initial clinical experience of patients who have undergone a right mini-thoracotomy Bentall. METHODS: This is a single-center retrospective review of seven patients who underwent a primary elective right anterior mini-thoracotomy Bentall. A thoracoscope was used in each case. Automated suturing technology was used for annular suturing in three of the seven patients. Clinical outcomes evaluated include 30-day mortality, intensive care and hospital length of stay, time to extubation, operative times, as well as postoperative sequelae including stroke, infection, and bleeding. RESULTS: Median cardiopulmonary bypass, cross-clamp, and circulatory arrest time were 217, 153, and 28 minutes, respectively. Median time to extubation was 10 hours and median intensive care unit and hospital stay was 1 and 4 days, respectively. One patient had a wound infection and one returned to the operating room for bleeding. There were no in-hospital or 30-day mortalities. CONCLUSIONS: The Bentall procedure can be performed through a right anterior mini-thoracotomy in selected patients with excellent clinical results.


Subject(s)
Aorta/surgery , Minimally Invasive Surgical Procedures/methods , Thoracotomy/methods , Female , Humans , Male , Middle Aged , Minimally Invasive Surgical Procedures/mortality , Minimally Invasive Surgical Procedures/statistics & numerical data , Morbidity , Operative Time , Retrospective Studies , Thoracotomy/mortality , Thoracotomy/statistics & numerical data
8.
Ann Transl Med ; 6(15): 314, 2018 Aug.
Article in English | MEDLINE | ID: mdl-30211202

ABSTRACT

Focused research targeting an identified clinical problem may result in more rapid development of medical devices, technologies, and surgical techniques that directly impact patient care. These medical advances to improve patient care may be expedited by adopting an interactive translational research model in which inventors, designers, and engineers work in collaboration with surgeons. In addition, cadaveric simulation is a high-fidelity model that is bridging the translational and logistical gap to bring new surgical devices, technologies, and techniques to patients. We describe the partnership between the University of Rochester and LSI SOLUTIONS® in which an interactive translational research model utilizing cadaveric simulation has been successfully applied to accelerate bringing minimally invasive cardiac surgical techniques and innovative devices to patients.

9.
Article in English | MEDLINE | ID: mdl-29781589

ABSTRACT

Bentall procedures are traditionally performed through a median sternotomy. However, minimally invasive approaches are increasingly being utilized. A right mini-thoracotomy approach may improve postoperative recovery.  A 5-cm mini-thoracotomy is performed in the right 2nd intercostal space. A camera port is placed lateral to this incision. Peripheral cannulation is performed. The ascending aorta is cross-clamped. Cardioplegia is administered and the patient is placed in deep hypothermic circulatory arrest to construct the distal aortic anastomosis. Aortic leaflets are excised and the annulus is sized. Annular and prosthetic sutures are placed using shafted instruments or automated suturing devices. The coronary buttons are reimplanted and a graft-to-graft anastomosis is constructed.  The Bentall procedure can be done safely through a right mini-thoracotomy in select patients and we demonstrate our technique in this video tutorial. Automated suturing devices and video guidance may facilitate this procedure.


Subject(s)
Aorta/surgery , Aortic Aneurysm, Thoracic/surgery , Minimally Invasive Surgical Procedures/methods , Suture Techniques/instrumentation , Thoracotomy/methods , Vascular Surgical Procedures/methods , Aged , Equipment Design , Humans , Middle Aged
12.
Obes Surg ; 19(2): 257-260, 2009 Feb.
Article in English | MEDLINE | ID: mdl-18688687

ABSTRACT

We report a case of a 59-year-old female with esophageal perforation following endoscopic removal of an intragastric balloon. To our knowledge, this is the first case of esophageal perforation associated with intragastric balloon extraction reported in the English literature.


Subject(s)
Bariatric Surgery/instrumentation , Device Removal/adverse effects , Esophageal Perforation/etiology , Gastric Balloon/adverse effects , Obesity, Morbid/surgery , Endoscopy, Gastrointestinal , Esophageal Perforation/diagnosis , Female , Gastric Outlet Obstruction/diagnosis , Gastric Outlet Obstruction/etiology , Humans , Mediastinal Emphysema/diagnostic imaging , Mediastinal Emphysema/etiology , Mediastinitis/diagnostic imaging , Mediastinitis/etiology , Middle Aged , Subcutaneous Emphysema/etiology , Tomography, X-Ray Computed
14.
J Am Coll Surg ; 198(3): 404-9, 2004 Mar.
Article in English | MEDLINE | ID: mdl-14992743

ABSTRACT

BACKGROUND: Cardiopulmonary bypass has often been applied to revive victims of cold water drowning. The success of resuscitative efforts in patients who have sustained severe hypothermia is largely determined by neurologic outcomes. Measurement of Fos, the protein product of the immediate-early gene c-fos, is a marker of cerebral injury. STUDY DESIGN: Twenty-eight infant lambs were sedated and ventilated. Group 1 lambs were immersed in a cold water bath for 2 hours (17.3 +/- 2.7 degrees C). Group 2 lambs were placed on normothermic cardiopulmonary bypass for 2 hours (37.7 degrees +/- 0.7 degrees C). Group 3 lambs were immersed in a cold water bath for 2 hours (17.6 degrees +/- 2.4 degrees C), and then rewarmed for a period of 2 hours on cardiopulmonary bypass (37.0 degrees +/- 0.6 degrees C). The lambs were euthanized and immunohistochemical analysis for neuronal Fos was performed. RESULTS: There was significant induction of Fos-labeled nuclear profiles (cells/1130 microm(2)) in group 3 in the hippocampal regions and dentate gyrus compared with groups 1 and 2 (p < 0.001). CONCLUSION: Isolated exposure to either hypothermia or cardiopulmonary bypass results in minimal expression of neuronal Fos; the significant induction of Fos in the group 3 animals may represent an ischemic-reperfusion phenomenon. Modifications of rewarming techniques that minimize Fos expression may improve neurologic outcomes in victims of cold water drowning.


Subject(s)
Brain Damage, Chronic/pathology , Drowning/pathology , Hypothermia/pathology , Proto-Oncogene Proteins c-fos/analysis , Reperfusion Injury/pathology , Rewarming , Animals , Animals, Newborn , Cardiopulmonary Bypass , Cell Death/physiology , Dentate Gyrus/pathology , Hippocampus/pathology , Neurons/pathology , Sheep
15.
Ann Thorac Surg ; 76(4): 1066-71; discussion 1071-2, 2003 Oct.
Article in English | MEDLINE | ID: mdl-14529986

ABSTRACT

BACKGROUND: Insertion of a competent pulmonary valve has been advocated to reduce right ventricular volume overload associated with pulmonary regurgitation (PR) after repair of tetralogy of Fallot. However the indications, proper timing, and long-term benefits of restoring pulmonary valve function remain controversial. METHODS: Thirty-six patients (aged 15.2 +/- 9.2 years) underwent pulmonary valve implantation (31 homografts, 5 heterografts) 12.2 +/- 6.9 years after tetralogy repair. Additional surgical procedures included pulmonary artery augmentation (n = 14), closure of septal defects (n = 10), and cryoablation and endocardial resection of ventricular tachycardia (n = 2). RESULTS: All patients have had clinical improvement in their exercise capacity. Preoperative and postoperative bicycle ergometry tests in 6 patients demonstrated significant improvement in the percent of predicted peak workload (68.5% +/- 19.8% to 80.7% +/- 17.4%, p < 0.015). One midterm death occurred in a 38-year-old patient with a history of ventricular tachycardia who died suddenly 2 years after pulmonary valve insertion. Postoperative echocardiographic measurements were available in 34 patients at a mean follow-up of 5 years. There was a 30% reduction in right ventricular end-diastolic diameter indexed to body surface area after surgery (30.1 +/- 10.2 to 18.6 +/- 6.0 mm/m(2), p < 0.0001). Two patients required conduit replacements at 1 and 9 years postoperatively. CONCLUSIONS: Timely insertion of a competent pulmonary valve in children, adolescents, and young adults with significant PR after tetralogy of Fallot repair results in subjective and objective improvement in exercise capacity and is associated with reduction in right ventricle size.


Subject(s)
Heart Valve Prosthesis Implantation , Pulmonary Valve/surgery , Tetralogy of Fallot/surgery , Adolescent , Adult , Child , Child, Preschool , Exercise Tolerance , Female , Follow-Up Studies , Humans , Infant , Infant, Newborn , Male , Postoperative Complications , Pulmonary Valve Insufficiency/surgery , Reoperation
16.
Echocardiography ; 19(8): 735-41, 2002 Nov.
Article in English | MEDLINE | ID: mdl-12487647

ABSTRACT

Epicardial coronary imaging using high frequency (7-12 MHz) ultrasound probes could aid the surgeon performing coronary artery bypass procedures by localizing the coronary artery segments underneath epicardial fat, identifying the site of coronary stenosis to be bypassed, evaluating the integrity of distal coronary artery, assessing the efficacy of anastomosis, and detecting anastomotic complications. While an ideal coronary imaging probe is yet to be developed, early clinical experience with vascular imaging probes applied on the coronary vessels suggests that epicardial coronary artery imaging could enhance the optimum performance of coronary interventions. Fabrication of a flexible high frequency probe that could be applied not only on the arteries on the anterior surface of the heart but also on the lateral and posterior surfaces could facilitate development of newer surgical procedures as well.


Subject(s)
Arteries/surgery , Cardiac Surgical Procedures , Coronary Vessels/surgery , Intraoperative Care , Pericardium/surgery , Arteries/diagnostic imaging , Coronary Vessels/diagnostic imaging , Echocardiography, Doppler , Heart Diseases/diagnostic imaging , Heart Diseases/physiopathology , Heart Diseases/surgery , Hemodynamics/physiology , Humans , Intraoperative Care/methods , Pericardium/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...