Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
J Am Soc Mass Spectrom ; 35(2): 224-233, 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38181191

ABSTRACT

Mass spectrometry imaging (MSI) allows for the spatially resolved detection of endogenous and exogenous molecules and atoms in biological samples, typically prepared as thin tissue sections. Desorption electrospray ionization (DESI) is one of the most commonly utilized MSI modalities in preclinical research. DESI ion source technology is still rapidly evolving, with new sprayer designs and heated inlet capillaries having recently been incorporated in commercially available systems. In this study, three iterations of DESI sprayer designs are evaluated: (1) the first, and until recently only, commercially available Waters sprayer; (2) a developmental desorption electro-flow focusing ionization (DEFFI)-type sprayer; and (3) a prototype of the newly released Waters commercial sprayer. A heated inlet capillary is also employed, allowing for controlled inlet temperatures up to 500 °C. These three sprayers are evaluated by comparative tissue imaging analyses of murine testes across this temperature range. Single ion intensity versus temperature trends are evaluated as exemplar cases for putatively identified species of interest, such as lactate and glutamine. A range of trends are observed, where intensities follow either increasing, decreasing, bell-shaped, or other trends with temperature. Data for all sprayers show approximately similar trends for the ions studied, with the commercial prototype sprayer (sprayer version 3) matching or outperforming the other sprayers for the ions investigated. Finally, the mass spectra acquired using sprayer version 3 are evaluated by uniform manifold approximation and projection (UMAP) and k-means clustering. This approach is shown to provide valuable insight that is complementary to the presented univariate evaluation for reviewing the parameter space in this study. Full spectral temperature optimization data are provided as supporting data to enable other researchers to design experiments that are optimal for specific ions.


Subject(s)
Bays , Spectrometry, Mass, Electrospray Ionization , Mice , Animals , Spectrometry, Mass, Electrospray Ionization/methods , Temperature , Hot Temperature , Ions
2.
J Am Soc Mass Spectrom ; 31(11): 2287-2295, 2020 Nov 04.
Article in English | MEDLINE | ID: mdl-32945667

ABSTRACT

Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) is a powerful label-free technique for mapping the spatial distribution of biomolecules directly from tissue. However, like most other MSI techniques, it suffers from low ionization yields and ion suppression effects for biomolecules that might be of interest for a specific application at hand. Recently, a form of laser postionization was introduced (coined MALDI-2) that critically boosts the ion yield for many glyco- and phospholipids by several orders of magnitude and makes the detection of further biomolecular species possible. While the MALDI-2 technique is being increasingly applied by the MSI community, it is still only implemented in fine vacuum ion sources in a pressure range of about 1-10 mbar. Here, we show the first implementation of the technique to a custom-built atmospheric pressure ion source coupled to an Orbitrap Elite system. We present results from parameter optimization of MALDI-2 at atmospheric pressure, compare our findings to previously published fine vacuum data, and show first imaging results from mouse cerebellum with a 20 µm pixel size. Our findings broaden the feasibility of the technique to overall more flexible atmospheric pressure ion sources.

3.
J Am Soc Mass Spectrom ; 30(7): 1284-1293, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30949969

ABSTRACT

Ultraviolet matrix-assisted laser desorption/ionization mass spectrometry imaging (UV-MALDI MSI) is a widely used technique for imaging molecular distributions within biological systems. While much work exists concerning desorption in UV-MALDI MS, the effects of commonly varied parameters for imaging applications (repetition rate, use of continuous raster mode and raster speed), which determine spatial resolution and limits of detection for the technique, remain largely unknown. We use multiple surface characterization modalities to obtain quantitative measurements of material desorption and analyte ion yield in thin film model systems of two matrix compounds, arising from different UV-MALDI MSI sampling conditions. Observed changes in resulting ablation feature point to matrix-dependent spatial resolution and laser-induced matrix modification effects. Analyte ion yields of 10-9 to 10-6 are observed. Complex changes in ion yield, between spot and raster sampling and arising from varied laser repetition rate and raster speed, are observed. Graphical Abstract.

4.
Anal Chim Acta ; 1051: 110-119, 2019 Mar 21.
Article in English | MEDLINE | ID: mdl-30661607

ABSTRACT

Matrix assisted laser desorption ionisation mass spectrometry (MALDI-MS) at atmospheric pressure (AP) is, with a few notable exceptions, overshadowed by its vacuum based forms and AP transmission mode (TM) MALDI-MS lacks the up-take its potential benefits might suggest. The reasons for this are not fully understood and it is clear further development is required to realise the flexibility and power of this ionisation method and geometry. Here we report the build of a new AP-TM-MALDI-MSI ion source with plasma ionisation enhancement. This novel ion source is used to analyse a selection of increasingly complex systems from molecular standards to murine brain tissue sections. Significant enhancement of detected ion intensity is observed in both positive and negative ion mode in all systems, with up to 2000 fold increases observed for a range of tissue endogenous species. The substantial improvements conferred by the plasma enhancement are then employed to demonstrate the acquisition of proof of concept tissue images, with high quality spectra obtained down to 10 × 10 µm pixel size.


Subject(s)
Atmospheric Pressure , Plasma Gases/chemistry , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Animals , Brain Chemistry , Equipment Design , Mice , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/instrumentation
5.
J Am Soc Mass Spectrom ; 29(3): 501-511, 2018 03.
Article in English | MEDLINE | ID: mdl-29468418

ABSTRACT

In ultraviolet matrix-assisted laser desorption/ionization mass spectrometry (UV-MALDI MS) matrix compound optical absorption governs the uptake of laser energy, which in turn has a strong influence on experimental results. Despite this, quantitative absorption measurements are lacking for most matrix compounds. Furthermore, despite the use of UV-MALDI MS to detect a vast range of compounds, investigations into the effects of laser energy have been primarily restricted to single classes of analytes. We report the absolute solid state absorption spectra of the matrix compounds α-cyano-4-hydroxycinnamic acid (CHCA), para-nitroaniline (PNA), 2-mercaptobenzothiazole (MBT), 2,5-dihydroxybenzoic acid (2,5-DHB), and 2,4,6-trihydroxyacetophenone (THAP). The desorption/ionization characteristics of these matrix compounds with respect to laser fluence was investigated using mixed systems of matrix with either angiotensin II, PC(34:1) lipid standard, or haloperidol, acting as representatives for typical classes of analyte encountered in UV-MALDI MS. The first absolute solid phase spectra for PNA, MBT, and THAP are reported; additionally, inconsistencies between previously published spectra for CHCA are resolved. In light of these findings, suggestions are made for experimental optimization with regards to matrix and laser wavelength selection. The relationship between matrix optical cross-section and wavelength-dependant threshold fluence, fluence of maximum ion yield, and R, a new descriptor for the change in ion intensity with fluence, are described. A matrix cross-section of 1.3 × 10-17 cm-2 was identified as a potential minimum for desorption/ionization of analytes. Graphical Abstract ᅟ.

6.
Nanotoxicology ; 10(2): 173-84, 2016.
Article in English | MEDLINE | ID: mdl-26001188

ABSTRACT

Solubility is an important physicochemical parameter in nanoregulation. If nanomaterial is completely soluble, then from a risk assessment point of view, its disposal can be treated much in the same way as "ordinary" chemicals, which will simplify testing and characterisation regimes. This review assesses potential techniques for the measurement of nanomaterial solubility and evaluates the performance against a set of analytical criteria (based on satisfying the requirements as governed by the cosmetic regulation as well as the need to quantify the concentration of free (hydrated) ions). Our findings show that no universal method exists. A complementary approach is thus recommended, to comprise an atomic spectrometry-based method in conjunction with an electrochemical (or colorimetric) method. This article shows that although some techniques are more commonly used than others, a huge research gap remains, related with the need to ensure data reliability.


Subject(s)
Chemistry Techniques, Analytical/methods , Chemistry Techniques, Analytical/standards , Nanostructures/chemistry , Analytic Sample Preparation Methods/methods , Colorimetry/methods , Electrochemical Techniques/methods , Models, Theoretical , Reproducibility of Results , Solubility , Spectrophotometry, Atomic
7.
Nanotoxicology ; 9(5): 636-42, 2015.
Article in English | MEDLINE | ID: mdl-25211549

ABSTRACT

Regulation for nanomaterials is urgently needed, and the drive to adopt an intelligent testing strategy is evident. Such a strategy will not only provide economic benefits but will also reduce moral and ethical concerns arising from animal testing. For regulatory purposes, such an approach is promoted by REACH, particularly the use of quantitative structure-activity relationships [(Q)SAR] as a tool for the categorisation of compounds according to their physicochemical and toxicological properties. In addition to compounds, (Q)SAR has also been applied to nanomaterials in the form of nano(Q)SAR. Although (Q)SAR in chemicals is well established, nano(Q)SAR is still in early stages of development and its successful uptake is far from reality. This article aims to identify some of the pitfalls and challenges associated with nano-(Q)SARs in relation to the categorisation of nanomaterials. Our findings show clear gaps in the research framework that must be addressed if we are to have reliable predictions from such models. Three major barriers were identified: the need to improve quality of experimental data in which the models are developed from, the need to have practical guidelines for the development of the nano(Q)SAR models and the need to standardise and harmonise activities for the purpose of regulation. Of these three, the first, i.e. the need to improve data quality requires immediate attention, as it underpins activities associated with the latter two. It should be noted that the usefulness of data in the context of nano-(Q)SAR modelling is not only about the quantity of data but also about the quality, consistency and accessibility of those data.


Subject(s)
Models, Theoretical , Nanostructures/chemistry , Nanotechnology , Quantitative Structure-Activity Relationship , Nanostructures/toxicity , Nanotechnology/methods , Nanotechnology/trends , Particle Size , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...