Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Neurol Surg B Skull Base ; 83(2): 203-209, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35433184

ABSTRACT

Objective Therapeutic hypothermia is a potentially powerful and controversial clinical tool for neuroprotection following acute neurologic pathology, particularly vascular injury. Indeed, therapeutic hypothermia remains a standard of care for postcardiac arrest ischemia and acute neonatal hypoxic-ischemic encephalopathy, improving both survival and outcomes. Although therapeutic hypothermia remains promising for cellular and systems-based neuronal protection in other neurologic injury states, the systemic side effects have limited clinical utility, confounded analysis of potential neurologic benefits, and precluded the completion of meaningful clinical trials. Methods To address such limitations, we developed and tested a novel, minimally invasive, neurocritical care device that employs continuous circulation of cold saline through the pharyngeal region to deliver focal cerebrovascular cooling. We conducted a preclinical safety and efficacy trial in six adult porcine animals to assess the validity and functionality of the NeuroSave device, and assess cooling potential following middle cerebral artery occlusion ( n = 2). Results NeuroSave consistently lowered brain parenchymal temperature by a median of 9°C relative to core temperature within 60 minutes of initiation, including in ischemic cerebral parenchyma. The core body temperature experienced a maximal reduction of 2°C, or 5% of body temperature, with no associated adverse effects identified. Conclusion The present study uses a large animal preclinical model to demonstrate the safety and efficacy of a novel, noninvasive device for the induction of robust and systemically safe hypothermia within the brain.

2.
Perfusion ; 35(2): 96-103, 2020 03.
Article in English | MEDLINE | ID: mdl-31238794

ABSTRACT

BACKGROUND/OBJECTIVE: Reduction of brain temperature remains the most common method of neuroprotection against ischemic injury employed during cardiac surgery. However, cooling delivered via the cardiopulmonary bypass circuit is brief and cooling the body core along with the brain has been associated with a variety of unwanted effects. This study investigated the feasibility and safety of a novel selective brain cooling approach to induce rapid, brain-targeted hypothermia independent of the cardiopulmonary bypass circuit. METHODS: This first-in-human feasibility study enrolled five adults undergoing aortic valve replacement with cardiopulmonary bypass support. During surgery, the NeuroSave system circulated chilled saline within the pharynx and upper esophagus. Brain and body core temperature were continuously monitored. Adverse effects, cardiopulmonary function, and device function were noted. RESULTS: Patient 1 received cooling fluid for an insignificant period, and Patients 2-5 successfully underwent the cooling procedure using the NeuroSave system for 56-89 minutes. Cooling fluid was 12°C for Patients 1-3, 6°C for Patient 4, and 2°C for Patient 5. There were no NeuroSave-related adverse events and no alterations in cardiopulmonary function during NeuroSave use. Brain temperature decreased by 3°C within 15 minutes and remained at least 3.5°C colder than the body core. During a brief episode of hypotension in one patient, the brain cooled an additional 4°C in 2 minutes, briefly reaching 27.4°C. CONCLUSION: The NeuroSave system can induce rapid brain-targeted hypothermia and simultaneously maintain a favorable body-brain temperature gradient, even during hypotension. Further studies are required to evaluate the function of the system during longer periods of use.


Subject(s)
Brain Injuries/therapy , Brain/physiopathology , Hypothermia, Induced/methods , Aged , Aged, 80 and over , Feasibility Studies , Female , Humans , Male , Middle Aged , Prospective Studies
3.
Biotechnol Prog ; 27(3): 757-65, 2011.
Article in English | MEDLINE | ID: mdl-21448991

ABSTRACT

Top performing clones have failed at the manufacturing scale while the true best performer may have been rejected early in the screening process. Therefore, the ability to screen multiple clones in complex fed-batch processes using multiple process variations can be used to assess robustness and to identify critical factors. This dynamic ranking of clones' strategy requires the execution of many parallel experiments than traditional approaches. Therefore, this approach is best suited for micro-bioreactor models which can perform hundreds of experiments quickly and efficiently. In this study, a fully monitored and controlled small scale platform was used to screen eight CHO clones producing a recombinant monoclonal antibody across several process variations, including different feeding strategies, temperature shifts and pH control profiles. The first screen utilized 240 micro-bioreactors were run for two weeks for this assessment of the scale-down model as a high-throughput tool for clone evaluation. The richness of the outcome data enable to clearly identify the best and worst clone as well as process in term of maximum monoclonal antibody titer. The follow-up comparison study utilized 180 micro-bioreactors in a full factorial design and a subset of 12 clone/process combinations was selected to be run parallel in duplicate shake flasks. Good correlation between the micro-bioreactor predictions and those made in shake flasks with a Pearson correlation value of 0.94. The results also demonstrate that this micro-scale system can perform clone screening and process optimization for gaining significant titer improvements simultaneously. This dynamic ranking strategy can support better choices of production clones.


Subject(s)
Cloning, Molecular/methods , High-Throughput Screening Assays/methods , Recombinant Proteins/biosynthesis , Animals , Antibodies, Monoclonal/biosynthesis , Antibodies, Monoclonal/genetics , CHO Cells , Cell Culture Techniques/methods , Clone Cells , Cricetinae , Cricetulus , High-Throughput Screening Assays/instrumentation , Miniaturization
4.
Biotechnol Bioeng ; 104(6): 1107-20, 2009 Dec 15.
Article in English | MEDLINE | ID: mdl-19623562

ABSTRACT

Multi-factorial experimentation is essential in understanding the link between mammalian cell culture conditions and the glycoprotein product of any biomanufacturing process. This understanding is increasingly demanded as bioprocess development is influenced by the Quality by Design paradigm. We have developed a system that allows hundreds of micro-bioreactors to be run in parallel under controlled conditions, enabling factorial experiments of much larger scope than is possible with traditional systems. A high-throughput analytics workflow was also developed using commercially available instruments to obtain product quality information for each cell culture condition. The micro-bioreactor system was tested by executing a factorial experiment varying four process parameters: pH, dissolved oxygen, feed supplement rate, and reduced glutathione level. A total of 180 micro-bioreactors were run for 2 weeks during this DOE experiment to assess this scaled down micro-bioreactor system as a high-throughput tool for process development. Online measurements of pH, dissolved oxygen, and optical density were complemented by offline measurements of glucose, viability, titer, and product quality. Model accuracy was assessed by regressing the micro-bioreactor results with those obtained in conventional 3 L bioreactors. Excellent agreement was observed between the micro-bioreactor and the bench-top bioreactor. The micro-bioreactor results were further analyzed to link parameter manipulations to process outcomes via leverage plots, and to examine the interactions between process parameters. The results show that feed supplement rate has a significant effect (P < 0.05) on all performance metrics with higher feed rates resulting in greater cell mass and product titer. Culture pH impacted terminal integrated viable cell concentration, titer and intact immunoglobulin G titer, with better results obtained at the lower pH set point. The results demonstrate that a micro-scale system can be an excellent model of larger scale systems, while providing data sets broader and deeper than are available by traditional methods.


Subject(s)
Antibodies, Monoclonal/biosynthesis , Biotechnology/methods , Culture Media/chemistry , Animals , CHO Cells , Cricetinae , Cricetulus , Glutathione , Hydrogen-Ion Concentration , Oxygen , Recombinant Proteins/biosynthesis
SELECTION OF CITATIONS
SEARCH DETAIL
...