Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Pharm ; 632: 122545, 2023 Feb 05.
Article in English | MEDLINE | ID: mdl-36581106

ABSTRACT

Near infrared (NIR) and Raman spectroscopy combined with multivariate analysis are established techniques for the identification and quantification of chemical properties of pharmaceutical tablets like the concentration of active pharmaceutical ingredients (API). However, these techniques suffer from a high sensitivity to particle size variations and are not ideal for the characterization of physical properties of tablets such as tablet density. In this work, we have explored the feasibility of terahertz frequency-domain spectroscopy, with the advantage of low scattering effects, combined with multivariate analysis to quantify API concentration and tablet density. We studied 33 tablets, consisting of Ibuprofen, Mannitol, and a lubricant with API concentration and filler particle size as the design factors. The terahertz signal was measured in transmission mode across the frequency range 750 GHz to 1.5 THz using a vector network analyzer, frequency extenders, horn antennas, and four off-axis parabolic mirrors. The attenuation spectral data were pre-processed and orthogonal partial least square (OPLS) regression was applied to the spectral data to obtain quantitative prediction models for API concentration and tablet density. The performance of the models was assessed using test sets. While a fair model was obtained for API concentration, a high-quality model was demonstrated for tablet density. The coefficient of determination (R2) for the calibration set was 0.97 for tablet density and 0.98 for API concentration, while the relative prediction errors for the test set were 0.7% and 6% for tablet density and API concentration models, respectively. In conclusion, terahertz spectroscopy demonstrated to be a complementary technique to Raman and NIR spectroscopy, which enables the characterization of physical properties of tablets like tablet density, and the characterization of API concentration with the advantage of low scattering effects.


Subject(s)
Excipients , Spectroscopy, Near-Infrared , Spectroscopy, Near-Infrared/methods , Tablets/chemistry , Multivariate Analysis , Excipients/chemistry , Calibration
2.
Int J Pharm ; 618: 121579, 2022 Apr 25.
Article in English | MEDLINE | ID: mdl-35181461

ABSTRACT

Porosity is an important property of pharmaceutical tablets since it may affect tablet disintegration, dissolution, and bio-availability. It is, therefore, essential to establish non-destructive, fast, and compact techniques to assess porosity, in situ, during the manufacturing process. In this paper, the terahertz frequency-domain (THz-FD) technique was explored as a fast, non-destructive, and sensitive technique for porosity measurement of pharmaceutical tablets. We studied a sample set of 69 tablets with different design factors, such as particle size of the active pharmaceutical ingredient (API), Ibuprofen, particle size of the filler, Mannitol, API concentration, and compaction force. The signal transmitted through each tablet was measured across the frequency range 500-750 GHz using a vector network analyzer combined with a quasi-optical set-up consisting of four off-axis parabolic mirrors to guide and focus the beam. We first extracted the effective refractive index of each tablet from the measured complex transmission coefficients and then translated it to porosity, using an empirical linear relation between effective refractive index and tablet density. The results show that the THz-FD technique was highly sensitive to the variations of the design factors, showing that filler particle size and compaction force had a significant impact on the effective refractive index of the tablets and, consequently, porosity. Moreover, the fragmentation behaviour of particles was observed by THz porosity measurements and was verified with scanning electron microscopy of the cross-section of tablets. In conclusion, the THz-FD technique, based on electronic solutions, allows for fast, sensitive, and non-destructive porosity measurement that opens for compact instrument systems capable of in situ sensing in tablet manufacturing.


Subject(s)
Terahertz Spectroscopy , Excipients , Particle Size , Porosity , Tablets , Technology, Pharmaceutical/methods , Terahertz Spectroscopy/methods
3.
J Synchrotron Radiat ; 28(Pt 1): 64-70, 2021 Jan 01.
Article in English | MEDLINE | ID: mdl-33399553

ABSTRACT

Protein dynamics contribute to protein function on different time scales. Ultrafast X-ray diffraction snapshots can visualize the location and amplitude of atom displacements after perturbation. Since amplitudes of ultrafast motions are small, high-quality X-ray diffraction data is necessary for detection. Diffraction from bovine trypsin crystals using single femtosecond X-ray pulses was recorded at FemtoMAX, which is a versatile beamline of the MAX IV synchrotron. The time-over-threshold detection made it possible that single photons are distinguishable even under short-pulse low-repetition-rate conditions. The diffraction data quality from FemtoMAX beamline enables atomic resolution investigation of protein structures. This evaluation is based on the shape of the Wilson plot, cumulative intensity distribution compared with theoretical distribution, I/σ, Rmerge/Rmeas and CC1/2 statistics versus resolution. The FemtoMAX beamline provides an interesting alternative to X-ray free-electron lasers when studying reversible processes in protein crystals.


Subject(s)
Crystallography, X-Ray , Trypsin/chemistry , Animals , Cattle , Macromolecular Substances/chemistry , Photons , Synchrotrons
4.
Sci Rep ; 9(1): 19281, 2019 12 17.
Article in English | MEDLINE | ID: mdl-31848402

ABSTRACT

Low-frequency vibrations are crucial for protein structure and function, but only a few experimental techniques can shine light on them. The main challenge when addressing protein dynamics in the terahertz domain is the ubiquitous water that exhibit strong absorption. In this paper, we observe the protein atoms directly using X-ray crystallography in bovine trypsin at 100 K while irradiating the crystals with 0.5 THz radiation alternating on and off states. We observed that the anisotropy of atomic displacements increased upon terahertz irradiation. Atomic displacement similarities developed between chemically related atoms and between atoms of the catalytic machinery. This pattern likely arises from delocalized polar vibrational modes rather than delocalized elastic deformations or rigid-body displacements. The displacement correlation between these atoms were detected by a hierarchical clustering method, which can assist the analysis of other ultra-high resolution crystal structures. These experimental and analytical tools provide a detailed description of protein dynamics to complement the structural information from static diffraction experiments.


Subject(s)
Catalysis/radiation effects , Protein Conformation/radiation effects , Proteins/ultrastructure , Trypsin/ultrastructure , Animals , Anisotropy , Cattle , Crystallography, X-Ray , Models, Molecular , Proteins/chemistry , Proteins/radiation effects , Radiation , Trypsin/chemistry , Trypsin/radiation effects , Vibration , Water/chemistry
5.
Struct Dyn ; 2(5): 054702, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26798828

ABSTRACT

Whether long-range quantum coherent states could exist in biological systems, and beyond low-temperature regimes where quantum physics is known to be applicable, has been the subject to debate for decades. It was proposed by Fröhlich that vibrational modes within protein molecules can order and condense into a lowest-frequency vibrational mode in a process similar to Bose-Einstein condensation, and thus that macroscopic coherence could potentially be observed in biological systems. Despite the prediction of these so-called Fröhlich condensates almost five decades ago, experimental evidence thereof has been lacking. Here, we present the first experimental observation of Fröhlich condensation in a protein structure. To that end, and to overcome the challenges associated with probing low-frequency molecular vibrations in proteins (which has hampered understanding of their role in proteins' function), we combined terahertz techniques with a highly sensitive X-ray crystallographic method to visualize low-frequency vibrational modes in the protein structure of hen-egg white lysozyme. We found that 0.4 THz electromagnetic radiation induces non-thermal changes in electron density. In particular, we observed a local increase of electron density in a long α-helix motif consistent with a subtle longitudinal compression of the helix. These observed electron density changes occur at a low absorption rate indicating that thermalization of terahertz photons happens on a micro- to milli-second time scale, which is much slower than the expected nanosecond time scale due to damping of delocalized low frequency vibrations. Our analyses show that the micro- to milli-second lifetime of the vibration can only be explained by Fröhlich condensation, a phenomenon predicted almost half a century ago, yet never experimentally confirmed.

SELECTION OF CITATIONS
SEARCH DETAIL
...