Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 31(25): 42327-42337, 2023 Dec 04.
Article in English | MEDLINE | ID: mdl-38087608

ABSTRACT

We demonstrate how the depleted pump of an optical parametric amplifier can be recycled for impulsive alignment of a molecular gas inside a hollow-core fiber and use such alignment for the broadening and frequency shift of the signal pulse at a center wavelength of ∼1300 nm. Our results combine non-adiabatic molecular alignment, self-phase modulation, and Raman non-linearities. We demonstrate spectral shifts of up to 204 nm and a spectral broadening of more than one octave. We also report on the time delays at which broadening occurs, which do not coincide with any of the molecular rotational constants. Further, we encounter that maximum frequency shifts occur when the signal and pump have perpendicular polarization instead of parallel.

2.
Rev Sci Instrum ; 94(1): 013303, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-36725611

ABSTRACT

Since their inception, velocity map imaging (VMI) techniques have received continued interest in their expansion from 2D to 3D momentum measurements through either reconstructive or direct methods. Recently, much work has been devoted to the latter of these by relating electron time-of-flight (TOF) to the third momentum component. The challenge is having a timing resolution sufficient to resolve the structure in the narrow (<10 ns) electron TOF spread. Here, we build upon the work in VMI lens design and 3D VMI measurement by using a plano-convex thick-lens (PCTL) VMI in conjunction with an event-driven camera (TPX3CAM) providing TOF information for high resolution 3D electron momentum measurements. We perform simulations to show that, with the addition of a mesh electrode to the thick-lens geometry, the resulting plano-convex electrostatic field extends the detectable electron cutoff energy range while retaining the high resolution. This design also extends the electron TOF range, allowing for a better momentum resolution along this axis. We experimentally demonstrate these capabilities by examining above-threshold ionization in xenon, where the apparatus is shown to collect electrons of energy up to ∼7 eV with a TOF spread of ∼30 ns, both of which are improved compared to a previous work by factors of ∼1.4 and ∼3.75, respectively. Finally, the PCTL-VMI is equipped with a coincident ion TOF spectrometer, which is shown to effectively extract unique 3D momentum distributions for different ionic species in a gas mixture. These techniques have the potential to lend themselves to more advanced measurements involving systems where the electron momentum distributions possess non-trivial symmetries.

3.
Opt Express ; 23(26): 33295-300, 2015 Dec 28.
Article in English | MEDLINE | ID: mdl-26831994

ABSTRACT

We report on ultra-short stretched pulse generation in an all-fiber erbium-doped ring laser with a highly-nonlinear germanosilicate fiber inside the resonator with a slightly positive net-cavity group velocity dispersion (GVD). Stable 84 fs pulses were obtained with a 12 MHz repetition rate at a central wavelength of 1560 nm with a 48.1 nm spectral pulse width (full width at half maximum, FWHM) and 30 mW average output power; this corresponds to the 29.7 kW maximum peak power and 2.5 nJ pulse energy obtained immediately from the oscillator.

SELECTION OF CITATIONS
SEARCH DETAIL
...