Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Metas enferm ; 17(9): 58-64, nov. 2014. tab
Article in Spanish | IBECS | ID: ibc-131514

ABSTRACT

OBJETIVO: comprobar la relación que existe entre el uso o no de heparina sódica y la coagulación de los filtros en técnicas continuas de depuración extrarrenal (TCDE). MATERIAL Y MÉTODO: estudio descriptivo transversal realizado en una Unidad de Cuidados Intensivos (UCI) durante dos años. Se incluyeron a todos los pacientes que en dicho periodo fueron sometidos a TCDE. Se recogieron variables sociodemográficas, uso de heparina sódica, duración, motivos de retirada y coagulación del filtro. Se utilizó estadística descriptiva e inferencia estadística mediante la prueba T de Student y U de Mann-Whitney. RESULTADOS: se obtuvo una muestra de 50 pacientes y 162 filtros. En un 66% de los pacientes se utilizó heparina. La media de duración del filtro con heparina fue 27,1 horas frente a las 19 horas en los no se utilizó (p= 0,004). El principal motivo de retirada de los filtros fue la coagulación, tanto en los que se usó heparina (71%), como en los que no se usó (70%). CONCLUSIONES: la utilización de heparina sódica en TCDE aumenta la vida media del filtro. La coagulación del filtro es el motivo de retirada más habitual. El uso de heparina sódica conlleva un retraso en la coagulación del filtro


OBJECTIVE: to confirm the relationship existing between using or not using sodium heparine and filter clotting in Continuous Extrarenal Depuration Techniques (CEDTs). MATERIALS AND METHOD: a transversal descriptive study conducted in the Intensive Care Unit (ICU) during two years. All patients who underwent CEDT during that period were included in the study. Sociodemographic variables were collected, as well as the use of sodium heparine, duration, reasons for removal, and filter clotting. Descriptive statistics and statistical inference were used, through Student's t Test and Mann-Whitney U Test. RESULTS: a sample of 50 patients and 162 filters was obtained. Heparine was used in 66% of patients. The mean duration of the filter with heparine was 27.1 vs. 19 hours in those were it was not used (p= 0.004). The main reason for removing filters was clotting, both for those where heparine was used (71%), and for those where it was not used (70%). CONCLUSIONS: the use of sodium heparine in CEDT increases the mean life of the filter. Filter clotting is the most usual reason of removal. The use of sodium heparine entails a delay in filter clotting


Subject(s)
Humans , Heparin/therapeutic use , Hemofiltration/methods , Blood Coagulation , Hemodiafiltration/methods , Metabolic Clearance Rate , Lipoprotein Lipase/analysis , Critical Care/statistics & numerical data
SELECTION OF CITATIONS
SEARCH DETAIL
...