Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 25(13): 14473-14482, 2017 Jun 26.
Article in English | MEDLINE | ID: mdl-28789033

ABSTRACT

In this work we present an Autocorrelation z-scan technique to measure, simultaneously, the spatial and temporal distribution of femtosecond pulses near the focal region of lenses. A second-order collinear autocorrelator is implemented before the lens under test to estimate the pulse width. Signals are obtained by translating a Two Photon Absorption (TPA) sensor along the optical axis and by measuring the second-order autocorrelation trace at each position z. The DC signal, which is typically not considered important, is taken into account since we have found that this signal provides relevant information. Experimental results are presented for different lenses and input wavefronts.

2.
J Opt Soc Am A Opt Image Sci Vis ; 31(4): 696-703, 2014 Apr 01.
Article in English | MEDLINE | ID: mdl-24695130

ABSTRACT

We present a theoretical analysis of the field distribution in the focal plane of a dispersionless, high numerical aperture (NA) aplanatic lens for an x-polarized short pulse. We compare the focused pulse spatial distribution with that of a focused continuous wave (CW) field and its temporal distribution with the profile of the incident pulse. Regardless of the aberration free nature of the focusing aplanatic lens, the temporal width of the focused pulse widens considerably for incident pulses with durations on the order of a few cycles due to the frequency-dependent nature of diffraction phenomena, which imposes a temporal diffraction limit for focused short pulses. The spatial distribution of the focused pulse is also affected by this dependence and is altered with respect to the diffraction limited distribution of the CW incident field. We have analyzed pulses with flat top and Gaussian spatial irradiance profiles and found that the focused pulse temporal widening is less for the Gaussian spatial irradiance pulse, whereas the spatial distribution variation is similar in both cases. We present results of the focused pulsewidth as a function of the NA for the two spatial irradiance distributions, which show that the Gaussian irradiance pulse outperforms the flat top pulse at preserving the incident pulse duration.

3.
Opt Express ; 20(13): 14015-29, 2012 Jun 18.
Article in English | MEDLINE | ID: mdl-22714467

ABSTRACT

We show that, in order to attain complete polarization control across a beam, two spatially resolved variable retardations need to be introduced to the light beam. The orientation of the fast axes of the retarders must be linearly independent on the Poincaré sphere if a fixed starting polarization state is used, and one of the retardations requires a range of 2π. We also present an experimental system capable of implementing this concept using two passes on spatial light modulators (SLMs). A third SLM pass can be added to control the absolute phase of the beam. Control of the spatial polarization and phase distribution of a beam has applications in high-NA microscopy, where these properties can be used to shape the focal field in three dimensions. We present some examples of such fields, both theoretically calculated using McCutchen's method and experimentally observed.


Subject(s)
Image Enhancement/instrumentation , Lenses , Lighting/instrumentation , Microscopy, Phase-Contrast/instrumentation , Equipment Design , Equipment Failure Analysis
4.
Opt Express ; 20(2): 1060-9, 2012 Jan 16.
Article in English | MEDLINE | ID: mdl-22274452

ABSTRACT

We show that the volumetric field distribution in the focal region of a high numerical aperture focusing system can be efficiently calculated with a three-dimensional Fourier transform. In addition to focusing in a single medium, the method is able to calculate the more complex case of focusing through a planar interface between two media of mismatched refractive indices. The use of the chirp z-transform in our numerical implementation of the method allows us to perform fast calculations of the three-dimensional focused field distribution with good accuracy.


Subject(s)
Fourier Analysis , Light , Models, Theoretical , Optics and Photonics/methods , Refractometry/methods , Electromagnetic Fields , Imaging, Three-Dimensional/methods , Imaging, Three-Dimensional/standards , Numerical Analysis, Computer-Assisted , Optics and Photonics/standards , Refractometry/standards
5.
Opt Lett ; 36(8): 1341-3, 2011 Apr 15.
Article in English | MEDLINE | ID: mdl-21499350

ABSTRACT

We present an approach to calculating the complex amplitude of a three-dimensional (3D) diffracted light field in the paraxial approximation based on a 3D Fourier transform. Starting from the Huygens-Fresnel principle, the method is first developed for the computation of the light distribution around the focus of an apertured spherical wave. The method, with modification, is then extended to treat the 3D diffraction of an aperture with an arbitrary transmittance function.


Subject(s)
Light , Scattering, Radiation , Fourier Analysis , Normal Distribution
SELECTION OF CITATIONS
SEARCH DETAIL
...