Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Orthop Surg Traumatol ; 32(4): 611-618, 2022 May.
Article in English | MEDLINE | ID: mdl-34052921

ABSTRACT

INTRODUCTION: Closed reduction and fixation using a cephalomedullary nail represents the accepted management of unstable intertrochanteric fractures. Cut-through has been described as a complication associated with the treatment. Although a hip arthroplasty may be the most predictable revision method, a non-prosthetic option can lead to similar results. The objective is to describe a non-prosthetic revision procedure in cases of cut-through. METHOD: We performed a retrospective analysis of our Institutional Registry for Hip Fractures in elderly patients (RIAFC) from January 2010 to June 2018 searching for cut-through as a failure after unstable intertrochanteric fracture treatment. REVISION PROCEDURE: (A) Helical blade removal, introduction of structural bone graft (autologous or allograft) as a plug to obliterate the communication to the joint and a new blade insertion. (B) Same as in A but augmenting the blade/head purchase with poly(methyl methacrylate) (PMMA). Before the cement insertion, a radio-opaque solution was instilled to assure lack of joint leakage. RESULTS: We evaluated 1616 patients. Sixteen of them presented a cut-through complication (1%). Ten of them were females with an average age for all of 84 years. One patient denied an implant revision and opted for a total joint replacement. In four of the patients, the procedure A was done, 2 of them had a new failure, and an joint arthroplasty was performed. In the B group, only one patient needed a revision to a total hip. The other 10 patients healed uneventfully and did not need any further intervention. CONCLUSION: Cut-through revision after fixation of unstable intertrochanteric fractures treated with cephalomedullary nail by blocking of the joint communication and augmenting the head blade purchase with PMMA is a safe and minimal invasive procedure, generates low blood loss and rate of complications and allows bone healing preserving the native joint. LEVEL OF EVIDENCE IV: Nil.


Subject(s)
Arthroplasty, Replacement , Fracture Fixation, Intramedullary , Hip Fractures , Aged, 80 and over , Bone Nails , Female , Fracture Fixation, Intramedullary/adverse effects , Fracture Fixation, Intramedullary/methods , Hip Fractures/surgery , Humans , Male , Polymethyl Methacrylate/therapeutic use , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...