Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Total Environ ; 847: 157499, 2022 Nov 15.
Article in English | MEDLINE | ID: mdl-35870601

ABSTRACT

In order to move forward in the acceptance of a novel contaminant monitoring technique (Diffusive Gradients in Thin-films: DGT) for assessment of marine water bodies, sensu the WFD, an Inter-Laboratories Comparison (ILC) exercise (nine Europeans laboratories) was organized in the framework of the Interreg Atlantic Area MONITOOL project, which focused on the use of the DGT technique for the measurement of WFD priority metals (Cd, Ni and Pb). Reproducible results were obtained for each metal by several laboratories, supporting the assertion that DGT analysis can be performed satisfactorily by laboratories experienced in measuring metals at trace levels in marine environments, even if they have limited practice in DGT analysis. According to the Z-score analysis, among the 9 participating laboratories, 3 had 100 % of satisfactory results for Cd, Ni, and Pb, 3 had >80 % satisfactory results and 2 had about 60 % satisfactory results. This work highlights the need to clearly describe the DGT method in order to control sources of contamination during analytical steps, in particular the resin gel retrieval and the elution steps. Such international intercomparison exercise is an important step to develop the laboratory network involved in DGT analysis and contributes to the improvement of data quality.


Subject(s)
Environmental Monitoring , Water Pollutants, Chemical , Cadmium/analysis , Diffusion , Environmental Monitoring/methods , Humans , Lead/analysis , Water/analysis , Water Pollutants, Chemical/analysis
2.
Article in English | MEDLINE | ID: mdl-34770100

ABSTRACT

The presence of ten metals (Cd, Ni, Pb, Cr, Cu, Zn, Al, Fe, Mn, and Co) was investigated in the final discharge of six facilities, including four wastewater treatment plants, which were continuously discharging treated wastewater to the coastal environment in Gran Canaria Island. A four-day sampling campaign was carried out at each facility in July 2020, in which both the spot samplings technique and the diffusive gradient in thin-film technique (DGT) were carried out to measure total dissolved metals and the in situ labile metal fraction, respectively. After the necessary sample preparation steps, measurements were carried out by ICP-MS for both samplings. Raw data referred to the spot total dissolved and DGT-labile metal concentrations were reported. In general, the average metal concentrations were dispersed in a broad range. As expected, the highest metal contents were found in those facilities with larger industrial contributions. The values of annual average environmental quality standards (AA-EQS) were used to assess the total dissolved metal concentrations for every metal in every final discharge. In only one of the studied facilities, some metals (Ni and Zn) exceeded these EQS within the receiving waterbody, highlighting the need for more efficient treatment targeted towards a specific discharging-water quality. In addition, the total dissolved and labile metal daily fluxes of discharge were calculated to estimate the contribution of every effluent to the receiving water bodies.


Subject(s)
Metals, Heavy , Water Pollutants, Chemical , Environmental Monitoring , Metals/analysis , Metals, Heavy/analysis , Spain , Wastewater , Water Pollutants, Chemical/analysis
3.
Sci Total Environ ; 783: 147001, 2021 Aug 20.
Article in English | MEDLINE | ID: mdl-33872893

ABSTRACT

The current study evaluates the effect of seawater physico-chemical characteristics on the relationship between the concentration of metals measured by Diffusive Gradients in Thin films (DGT) passive samplers (i.e., DGT-labile concentration) and the concentrations measured in discrete water samples. Accordingly, Inductively Coupled Plasma Mass Spectrometry (ICP-MS) was used to measure the total dissolved metal concentrations in the discrete water samples and the labile metal concentrations obtained by DGT samplers; additionally, lead and cadmium conditional labile fractions were determined by Anodic Stripping Voltammetry (ASV) and total dissolved nickel was measured by Cathodic Stripping Voltammetry (CSV). It can be concluded that, in general, the median ratios of DGT/ICP and DGT/ASV(CSV) were lower than 1, except for Ni (median ratio close to 1) and Zn (higher than 1). This indicates the importance of speciation and time-integrated concentrations measured using passive sampling techniques, which is in line with the WFD suggestions for improving the chemical assessment of waterbodies. It is the variability in metal content in waters rather than environmental conditions to which the variability of the ratios can be attributed. The ratios were not significantly affected by the temperature, salinity, pH, oxygen, DOC or SPM, giving a great confidence for all the techniques used. Within a regulatory context such as the EU Water Framework Directive this is a great advantage, since the simplicity of not needing to use corrections to minimize the effects of environmental variables could help in implementing DGTs within monitoring networks.

SELECTION OF CITATIONS
SEARCH DETAIL
...