Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Language
Publication year range
1.
Curr HIV Res ; 21(5): 323-329, 2023.
Article in English | MEDLINE | ID: mdl-37711011

ABSTRACT

BACKGROUND: Retroviruses are described as a risk factor for chronic neuropathy. However, it is still unknown if they can work as amyotrophic lateral sclerosis triggers. Over the years, some cases of this association have been described with heterogenous disclosures. CASE REPRESENTATION: This study aimed to report a case of HIV and ALS-like neuropathy and briefly discuss peculiarities of clinical aspects, such as physiopathology and treatment options. The patient underwent neurological examination associated with blood tests, electromyography, analysis of cerebrospinal fluid, and imaging studies. DISCUSSION: A non-systematic review was performed in major databases regarding the topic. The case presented mixed upper and lower motor neuron signs and was framed as a probable case of ALS following the present criteria. CONCLUSION: After a short follow-up and viral load cleansing, neurological stabilization was achieved.


Subject(s)
Amyotrophic Lateral Sclerosis , HIV Infections , Humans , Amyotrophic Lateral Sclerosis/diagnosis , Amyotrophic Lateral Sclerosis/complications , Amyotrophic Lateral Sclerosis/drug therapy , HIV Infections/complications , HIV Infections/drug therapy , Diagnosis, Differential
2.
Rev Assoc Med Bras (1992) ; 67(6): 816-821, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34709323

ABSTRACT

OBJECTIVE: Use Lead-DBS software to analyze stereotactical surgical outcome of an operated population and demonstrate that small target deviations do not compromise the stimulation of desired structures, even with small amperages. METHODS: Image exams of patients submitted to deep brain stimulation for movement disorders treatment were processed in Lead-DBS software. Electrode stereotactic coordinates were subtracted from the planned target and those deviations, compared among different anatomical targets and sides operated firstly and secondly. We also quantified the frequency of relation between the activated tissue volume and the planned target through computer simulations. RESULTS: None of the 16 electrodes were exactly implanted at the planned coordinates. A stimulation of 3 mA reached 62.5% of the times the planned coordinates, rising to 68.75% with a 3,5 mA. No statistical significance was demonstrated in any comparison of laterality and anatomical sites. CONCLUSIONS: The simulation of small amperage fields could reach the intended target even when electrode placement is suboptimal. Furthermore, such a goal can be achieved without overlapping the volume of activated tissue with undesired structures. Software Lead-DBS proved to be a valuable complementary asset for surgical stereotactical result assessment.


Subject(s)
Deep Brain Stimulation , Electrodes, Implanted , Humans , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Motivation
3.
Rev. Assoc. Med. Bras. (1992) ; 67(6): 816-821, June 2021. tab, graf
Article in English | LILACS | ID: biblio-1346905

ABSTRACT

SUMMARY OBJECTIVE: Use Lead-DBS software to analyze stereotactical surgical outcome of an operated population and demonstrate that small target deviations do not compromise the stimulation of desired structures, even with small amperages. METHODS: Image exams of patients submitted to deep brain stimulation for movement disorders treatment were processed in Lead-DBS software. Electrode stereotactic coordinates were subtracted from the planned target and those deviations, compared among different anatomical targets and sides operated firstly and secondly. We also quantified the frequency of relation between the activated tissue volume and the planned target through computer simulations. RESULTS: None of the 16 electrodes were exactly implanted at the planned coordinates. A stimulation of 3 mA reached 62.5% of the times the planned coordinates, rising to 68.75% with a 3,5 mA. No statistical significance was demonstrated in any comparison of laterality and anatomical sites. CONCLUSIONS: The simulation of small amperage fields could reach the intended target even when electrode placement is suboptimal. Furthermore, such a goal can be achieved without overlapping the volume of activated tissue with undesired structures. Software Lead-DBS proved to be a valuable complementary asset for surgical stereotactical result assessment.


Subject(s)
Humans , Deep Brain Stimulation , Magnetic Resonance Imaging , Imaging, Three-Dimensional , Electrodes, Implanted , Motivation
SELECTION OF CITATIONS
SEARCH DETAIL
...