Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Vasc Surg ; 104: 185-195, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38493886

ABSTRACT

BACKGROUND: In patients undergoing revascularization for peripheral arterial disease (PAD), low-dose Factor Xa inhibitors (FXaI) taken with aspirin improved limb and cardiovascular outcomes compared to aspirin alone. Furthermore, in atrial fibrillation and venous thromboembolism, FXaI are recommended over vitamin K antagonists (VKA) for chronic anticoagulation. While studies have evaluated different perioperative anticoagulation regimens in patients treated for PAD, the optimal regimen for chronic anticoagulation in patients with PAD undergoing peripheral vascular intervention (PVI) has not been determined. This analysis compares outcomes of patients after PVI that require chronic anticoagulation with FXaI and VKA. METHODS: The Vascular Quality Initiative-PVI database was used. Patients consistently treated with FXaI or VKA before the procedure, at discharge, and on long-term follow-up were defined as those receiving chronic anticoagulation. Patient demographics, procedural details, and perioperative and long-term outcomes were compared between FXaI and VKA groups. RESULTS: A total of 109,268 patients were analyzed, and 6,885 were chronically anticoagulated with FXaI (N = 2,427) or VKA (N = 4,458). Patients anticoagulated with VKA were more frequently males (65.3% vs. 61.0%, P < 0.001) with end-stage renal disease (9.7% vs. 4.6%, P < 0.001) and more likely to be treated for chronic limb-threatening ischemia (58.1% vs. 52.7%, P < 0.001). Rates of hematoma following PVI were significantly higher in patients taking VKA compared to FXaI (3.5% vs. 1.9%, P < 0.001). Multivariable logistic regression analysis showed that VKA were associated with increased perioperative hematoma than FXaI (odds ratio = 1.89 [1.30-2.82]). Compared to patients taking VKA, those receiving FXaI had lower rates of major amputation (6.7% vs. 8.4%, P = 0.020) and mortality (7.6% vs. 15.2%, P ≤ 0.001). Using Kaplan-Meier analysis, patients consistently anticoagulated with FXaI had improved amputation-free survival after PVI. Adjusting for significant patient and procedural characteristics, Cox proportional hazard regression demonstrated that there is an increased risk for major amputation or mortality in patients using VKA compared to FXaI (hazard ratio 1.61, [1.36-1.90]). CONCLUSIONS: Chronic anticoagulation with FXaI as compared to VKA was associated with superior perioperative and long-term outcomes in patients with PAD undergoing PVI. FXaI should be the preferred agents over VKA for chronic anticoagulation in patients with PAD undergoing PVI.


Subject(s)
Anticoagulants , Databases, Factual , Factor Xa Inhibitors , Peripheral Arterial Disease , Vitamin K , Humans , Male , Female , Aged , Peripheral Arterial Disease/diagnosis , Peripheral Arterial Disease/drug therapy , Factor Xa Inhibitors/adverse effects , Factor Xa Inhibitors/administration & dosage , Time Factors , Treatment Outcome , Risk Factors , Middle Aged , Vitamin K/antagonists & inhibitors , Retrospective Studies , Anticoagulants/adverse effects , Anticoagulants/administration & dosage , Aged, 80 and over , Amputation, Surgical , Hemorrhage/chemically induced , Drug Administration Schedule , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Risk Assessment , Limb Salvage , United States , Vascular Surgical Procedures/adverse effects
2.
J Vasc Surg Venous Lymphat Disord ; 12(2): 101731, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38081514

ABSTRACT

OBJECTIVE: Although inferior vena cava (IVC) filters are commonly retrieved using a snare, lateral tilt and fibrosis around struts can complicate the procedure and sometimes require the use of off-label devices. We describe the development of a novel articulating endovascular grasper designed to remove permanent and retrievable IVC filters in any configuration. METHODS: For in vitro testing, the IVC filters were anchored to the inner wall of a flexible tube in a centered or tilted configuration. A high-contrast backlit camera view simulated the two-dimensional fluoroscopy projection during retrieval. The time from the retrieval device introduction into the camera field to complete filter retrieval was measured in seconds. The control experiment involved temporary IVC filter retrieval with a snare. There were four comparative groups: (1) retrievable filter in centered configuration; (2) retrievable filter in tilted configuration; (3) permanent filter in centered configuration; and (4) permanent filter in tilted configuration. Every experiment was repeated five times, with median retrieval time compared with the control group. For in vivo testing in a porcine model, six tilted infrarenal IVC filters were retrieved with grasper via right jugular approach. Comparison analysis between animal and patient procedures was performed for the following variables: total procedure time, the retrieval time, and fluoroscopy time. RESULTS: The in vitro experiments showed comparable retrieval times between the experimental groups 1, 2, and 4 and the control. However, grasper removal of a centered permanent filter (group 3) required significantly less time than in the control (29 vs 79 seconds; P = .009). In the animal model, all IVC filters were retrieved using the grasper with no adverse events. The total procedure time (21.2 vs 43.5 minutes; P = .01) and the fluoroscopy time (4.3 vs 10 minutes; P = .044) were significantly shorter in the animal model compared with the patient group. Moreover, in the patient group, 16.7% of retrievals required advanced endovascular techniques, and one IVC filter could not be retrieved (success rate = 91.7%), whereas all the IVC filters were successfully retrieved in the animal model without the use of additional tools. CONCLUSIONS: The novel endovascular grasper is effective in retrieving different types of IVC filters in different configurations and compared favorably with the snare in the in vitro model. In vivo experiments demonstrated more effective retrieval when compared with matched patient retrievals.


Subject(s)
Endovascular Procedures , Vena Cava Filters , Humans , Animals , Swine , Vena Cava Filters/adverse effects , Device Removal/adverse effects , Retrospective Studies , Time Factors , Endovascular Procedures/adverse effects , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...